Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock

被引:94
|
作者
Varpula, Marjut [1 ]
Karlsson, Sari [1 ]
Ruokonen, Esko [1 ]
Pettila, Ville [1 ]
机构
[1] Helsinki Univ Hosp, Helsinki 00029, Finland
关键词
sepsis; septic shock; hemodynamic monitoring; outcome;
D O I
10.1007/s00134-006-0270-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Central venous oxygen saturation (ScvO(2)) in initial resuscitation is included in the Surviving Sepsis Campaign guidelines. ScvO(2) monitoring has also been suggested to be comparable to mixed venous oxygen saturation (SvO(2)) for clinical purposes. The aim of our study was to assess the correlation and agreement of ScvO(2) and SvO(2) and compare ScvO(2)-SvO(2) difference to lactate, oxygen-derived and hemodynamic parameters in early septic shock in ICU after initial resuscitation. Design and setting: Prospective clinical study with 16 patients with septic shock at two university hospital ICUs. A dose of norepinephrine over 0.1 mu g/kg/min was required for inclusion. Measurements and results: Five paired ScvO(2) and SvO(2) samples at 6-h intervals, altogether 72 samples, were collected during 24 h. The mean SvO(2) was below the mean ScvO(2) at all time points. Bias of difference was 4.2% and 95% limits of agreement ranged from -8.1% to 16.5%. The difference correlated significantly to CI and DO2. Conclusions: The difference between paired ScvO(2) and SvO(2) varies highly. Therefore, SvO(2) may not be estimated on the basis of ScvO(2) in treatment of septic shock after resuscitation period in ICU.
引用
收藏
页码:1336 / 1343
页数:8
相关论文
共 50 条
  • [31] MIXED VENOUS OXYGEN-SATURATION
    HANNEMANN, L
    REINHART, K
    ACTA MEDICA AUSTRIACA, 1993, 20 (04) : 107 - 111
  • [32] FEMORAL VENOUS OXYGEN SATURATION AS A SUBSTITUTE OF CENTRAL VENOUS OXYGEN SATURATION IN CRITICALLY ILL PATIENTS
    Marti, Y. N.
    Milena, L. B.
    de Azevedo, R. P.
    Machado, F. R.
    INTENSIVE CARE MEDICINE, 2013, 39 : S485 - S485
  • [33] Continuous monitoring of the central venous oxygen saturation in surgical patients: Comparison to the monitoring of the mixed venous saturation
    Cohendy, R
    Peries, C
    Lefrant, JY
    Doucot, PY
    Saissi, G
    Eledjam, JJ
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (08) : 956 - 956
  • [34] DOES CENTRAL VENOUS OXYGEN-SATURATION ACCURATELY REFLECT MIXED VENOUS OXYGEN-SATURATION - NOTHING IS SIMPLE, UNFORTUNATELY
    VINCENT, JL
    INTENSIVE CARE MEDICINE, 1992, 18 (07) : 386 - 387
  • [35] Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
    Dueck, MH
    Klimek, M
    Appenrodt, S
    Weigand, C
    Boerner, U
    ANESTHESIOLOGY, 2005, 103 (02) : 249 - 257
  • [36] DISCREPANCY BETWEEN CENTRAL VENOUS OXYGEN SATURATION AND MIXED VENOUS OXYGEN SATURATION IS A PREDICTOR OF NEUROLOGICAL COMPLICATION IN THORACIC AORTA SURGERY
    Maki, Jun
    Iseki, Satoshi
    Sugioka, Norimitsu
    Fujiyoshi, Tetsuhiro
    Aono, Hiromi
    Nakata, Shogo
    Tsutsumi, Yoshimitsu
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A100 - A100
  • [37] A Comparison of Central and Mixed Venous Oxygen Saturation in Circulatory Failure
    Ho, Kwok M.
    Harding, Richard
    Chamberlain, Jenny
    Bulsara, Max
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (03) : 434 - 439
  • [38] CENTRAL MIXED AND SPLANCHNIC VENOUS OXYGEN-SATURATION MONITORING
    DAHN, MS
    LANGE, MP
    JACOBS, LA
    INTENSIVE CARE MEDICINE, 1988, 14 (04) : 373 - 378
  • [39] Lack of equivalence between central and mixed venous oxygen saturation
    Chawla, LS
    Zia, H
    Gutierrez, G
    Katz, NM
    Seneff, MG
    Shah, M
    CHEST, 2004, 126 (06) : 1891 - 1896
  • [40] Central venous oxygen saturation in septic shock - a marker of cardiac output, microvascular shunting and/or dysoxia?
    Haase, Nicolai
    Perner, Anders
    CRITICAL CARE, 2011, 15 (04):