Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock

被引:94
|
作者
Varpula, Marjut [1 ]
Karlsson, Sari [1 ]
Ruokonen, Esko [1 ]
Pettila, Ville [1 ]
机构
[1] Helsinki Univ Hosp, Helsinki 00029, Finland
关键词
sepsis; septic shock; hemodynamic monitoring; outcome;
D O I
10.1007/s00134-006-0270-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Central venous oxygen saturation (ScvO(2)) in initial resuscitation is included in the Surviving Sepsis Campaign guidelines. ScvO(2) monitoring has also been suggested to be comparable to mixed venous oxygen saturation (SvO(2)) for clinical purposes. The aim of our study was to assess the correlation and agreement of ScvO(2) and SvO(2) and compare ScvO(2)-SvO(2) difference to lactate, oxygen-derived and hemodynamic parameters in early septic shock in ICU after initial resuscitation. Design and setting: Prospective clinical study with 16 patients with septic shock at two university hospital ICUs. A dose of norepinephrine over 0.1 mu g/kg/min was required for inclusion. Measurements and results: Five paired ScvO(2) and SvO(2) samples at 6-h intervals, altogether 72 samples, were collected during 24 h. The mean SvO(2) was below the mean ScvO(2) at all time points. Bias of difference was 4.2% and 95% limits of agreement ranged from -8.1% to 16.5%. The difference correlated significantly to CI and DO2. Conclusions: The difference between paired ScvO(2) and SvO(2) varies highly. Therefore, SvO(2) may not be estimated on the basis of ScvO(2) in treatment of septic shock after resuscitation period in ICU.
引用
收藏
页码:1336 / 1343
页数:8
相关论文
共 50 条
  • [21] CENTRAL VENOUS OXYGEN SATURATION IN SHOCK - STUDY IN MAN
    LEE, J
    BARBER, R
    WRIGHT, F
    STANLEY, L
    ANESTHESIOLOGY, 1972, 36 (05) : 472 - &
  • [22] Femoral venous oxygen saturation and central venous oxygen saturation in critically ill patients
    Zhang, Xiaohong
    Wang, Jiandong
    Dong, Yun
    Chen, Youdai
    JOURNAL OF CRITICAL CARE, 2015, 30 (04) : 768 - 772
  • [23] Central venous and mixed venous oxygen saturation in critically ill patients
    Ladakis, C
    Myrianthefs, P
    Karabinis, A
    Karatzas, G
    Dosios, T
    Fildissis, G
    Gogas, J
    Baltopoulos, G
    RESPIRATION, 2001, 68 (03) : 279 - 285
  • [24] CENTRAL VENOUS OXYGEN SATURATION IN PATIENTS WITH SEPTIC SHOCK: A SINGLE CENTER OBSERVATIONAL STUDY
    Jacobs, F. M.
    Prat, D.
    Brivet, F. G.
    INTENSIVE CARE MEDICINE, 2010, 36 : S241 - S241
  • [25] MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    MARTIN, C
    AUFFRAY, JP
    BADETTI, C
    PERRIN, G
    PAPAZIAN, L
    GOUIN, F
    INTENSIVE CARE MEDICINE, 1992, 18 (02) : 101 - 104
  • [26] Comparison of mixed venous oxygen saturation and central venous oxygen saturation in patients undergoing living donor liver transplantation
    Ri, H. -S
    Jeon, S.
    Yoon, J. -U
    TRANSPLANTATION, 2018, 102 : 202 - 202
  • [27] Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients
    Perner, A.
    Haase, N.
    Wiis, J.
    White, J. O.
    Delaney, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (01) : 98 - 102
  • [28] Study of the correlation between central venous oxygen saturation and venous saturation from the antecubital vein in severe sepsis/septic shock patients
    K Piyavechviratana
    W Tangpradubkiet
    Critical Care, 16 (Suppl 1):
  • [29] MIXED VENOUS OXYGEN-SATURATION
    PIANTADOSI, S
    BRADLEY, EL
    ANNALS OF EMERGENCY MEDICINE, 1981, 10 (10) : 548 - 548
  • [30] MIXED VENOUS OXYGEN-SATURATION
    REINHART, K
    SCHAFER, M
    RUDOLPH, T
    SPECHT, M
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 315 - 325