Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock

被引:94
|
作者
Varpula, Marjut [1 ]
Karlsson, Sari [1 ]
Ruokonen, Esko [1 ]
Pettila, Ville [1 ]
机构
[1] Helsinki Univ Hosp, Helsinki 00029, Finland
关键词
sepsis; septic shock; hemodynamic monitoring; outcome;
D O I
10.1007/s00134-006-0270-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Central venous oxygen saturation (ScvO(2)) in initial resuscitation is included in the Surviving Sepsis Campaign guidelines. ScvO(2) monitoring has also been suggested to be comparable to mixed venous oxygen saturation (SvO(2)) for clinical purposes. The aim of our study was to assess the correlation and agreement of ScvO(2) and SvO(2) and compare ScvO(2)-SvO(2) difference to lactate, oxygen-derived and hemodynamic parameters in early septic shock in ICU after initial resuscitation. Design and setting: Prospective clinical study with 16 patients with septic shock at two university hospital ICUs. A dose of norepinephrine over 0.1 mu g/kg/min was required for inclusion. Measurements and results: Five paired ScvO(2) and SvO(2) samples at 6-h intervals, altogether 72 samples, were collected during 24 h. The mean SvO(2) was below the mean ScvO(2) at all time points. Bias of difference was 4.2% and 95% limits of agreement ranged from -8.1% to 16.5%. The difference correlated significantly to CI and DO2. Conclusions: The difference between paired ScvO(2) and SvO(2) varies highly. Therefore, SvO(2) may not be estimated on the basis of ScvO(2) in treatment of septic shock after resuscitation period in ICU.
引用
收藏
页码:1336 / 1343
页数:8
相关论文
共 50 条
  • [1] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Marjut Varpula
    Sari Karlsson
    Esko Ruokonen
    Ville Pettilä
    Intensive Care Medicine, 2006, 32 : 1336 - 1343
  • [2] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock: reply to Dr. Bourdeaux
    Marjut Varpula
    Sari Karlsson
    Esko Ruokonen
    Ville Pettilä
    Intensive Care Medicine, 2007, 33 : 546 - 546
  • [3] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock:: reply to Dr. Bourdeaux
    Varpula, Marjut
    Karlsson, Sari
    Ruokonen, Esko
    Pettila, Ville
    INTENSIVE CARE MEDICINE, 2007, 33 (03) : 546 - 546
  • [4] Comment on Varpula et al.: Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Bourdeaux, Chris
    Hadfield, John
    INTENSIVE CARE MEDICINE, 2007, 33 (03) : 545 - 545
  • [5] Comment on Varpula et al.: Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Chris Bourdeaux
    John Hadfield
    Intensive Care Medicine, 2007, 33 : 545 - 545
  • [6] Mixed and central venous oxygen saturation in patients with septic shock: is there a difference?
    RB Carvalho
    FR Machado
    HP Guimarães
    APR Senna
    JLG Amaral
    Critical Care, 9 (Suppl 2):
  • [7] Intermittent Mixed Venous Oxygen Saturation in Pediatric Septic Shock
    Ami P. Shah
    Prerna Batra
    Indian Pediatrics, 2021, 58 : 1117 - 1118
  • [8] Intermittent Mixed Venous Oxygen Saturation in Pediatric Septic Shock
    Shah, Ami P.
    Batra, Prerna
    INDIAN PEDIATRICS, 2021, 58 (12) : 1117 - 1118
  • [9] Central Venous Oxygen Saturation Cannot Replace Mixed Venous Saturation in Patients Undergoing Cardiac Surgery
    Lorentzen, Anne-Grethe
    Lindskov, Christian
    Sloth, Erik
    Jakobsen, Carl-Johan
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (06) : 853 - 857
  • [10] Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation
    Turnaoglu, S
    Tugrul, M
    Çamci, E
    Çakar, N
    Akinci, Ö
    Ergin, P
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (05) : 574 - 579