Cone-beam CT angiography of the thorax - An experimental study

被引:1
|
作者
Yoshida, K
Tadokoro, H
Shimada, K
Endo, M
Satoh, K
Kitsukawa, S
Takami, A
Masuda, Y
Kusakabe, M
Sasaki, Y
机构
[1] Chiba Univ, Sch Med, Dept Internal Med 3, Chiba 2608677, Japan
[2] Natl Inst Radiol Sci, Div Adv Technol Med Imaging, Chiba 260, Japan
[3] Sony Corp, Res Ctr, Tokyo, Japan
来源
关键词
angiography; computed tomography; thorax; three-dimension;
D O I
10.1253/jcj.63.789
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256x256x256 voxel volume with a voxel dimension of 0.9x0.9x0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging.
引用
收藏
页码:789 / 793
页数:5
相关论文
共 50 条
  • [41] Early clinical experience on cone-beam CT
    Yumi Makimoto
    Kenji Matsuzaki
    Shusaku Yoshida
    Hiromu Nishitani
    Journal of Digital Imaging, 1998, 11 : 211 - 213
  • [42] Measurements for quality assurance in the cone-beam CT
    Walter, C.
    Wertz, H.
    Steil, V.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 95 - 96
  • [43] Dentomaxillofacial cone-beam CT for orthodontic assessment
    Farman, AG
    Scarfe, WC
    Hilgers, MJ
    Bida, O
    Moshiri, M
    Sukovic, P
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1187 - 1190
  • [44] Cone-beam CT of the internal carotid artery
    Hyde, DE
    Naik, S
    Habets, DF
    Holdsworth, DW
    MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 : 408 - 415
  • [45] Correction of scatter in megavoltage cone-beam CT
    Spies, L
    Ebert, M
    Groh, BA
    Hesse, BM
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : 821 - 833
  • [46] Exact Interior Reconstruction with Cone-Beam CT
    Ye, Yangbo
    Yu, Hengyong
    Wang, Ge
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2007, 2007
  • [47] Quality assurance of megavoltage cone-beam CT
    Morin, O.
    Aubin, M.
    Aubry, J.
    Chen, J.
    Descovich, M.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [48] Iterative cardiac cone-beam CT reconstruction
    Nielsen, T
    Manzke, R
    Koehler, T
    Grass, M
    Proksa, R
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2003 - 2014
  • [49] Cone-beam CT reconstruction for planar object
    Liu, Tong
    NDT & E INTERNATIONAL, 2012, 45 (01) : 9 - 15
  • [50] Cone-Beam CT of the Extremities in Clinical Practice
    Doan, Matthew K.
    Long, Jeremiah R.
    Verhey, Erik
    Wyse, Aaron
    Patel, Karan
    Flug, Jonathan A.
    RADIOGRAPHICS, 2024, 44 (03)