Cone-beam CT angiography of the thorax - An experimental study

被引:1
|
作者
Yoshida, K
Tadokoro, H
Shimada, K
Endo, M
Satoh, K
Kitsukawa, S
Takami, A
Masuda, Y
Kusakabe, M
Sasaki, Y
机构
[1] Chiba Univ, Sch Med, Dept Internal Med 3, Chiba 2608677, Japan
[2] Natl Inst Radiol Sci, Div Adv Technol Med Imaging, Chiba 260, Japan
[3] Sony Corp, Res Ctr, Tokyo, Japan
来源
关键词
angiography; computed tomography; thorax; three-dimension;
D O I
10.1253/jcj.63.789
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256x256x256 voxel volume with a voxel dimension of 0.9x0.9x0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging.
引用
收藏
页码:789 / 793
页数:5
相关论文
共 50 条
  • [21] Clinical implementation of a cone-beam CT
    Betgen, A
    van Herk, M
    Remeijer, P
    Sonke, JJ
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S158 - S158
  • [22] Flat Detector Cone-Beam CT
    Kachelriess, Marc
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (02): : 91 - 91
  • [23] Cone-beam CT experience in Aarau
    Cossmann, PH
    Stuessi, A
    von Briel, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S9 - S9
  • [24] Cone-beam CT for radiotherapy applications
    Cho, P.S.
    Johnson, R.H.
    Griffin, T.W.
    1863, Institute of Physics Publishing Ltd, Bristol, Engl (40):
  • [25] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1863 - 1883
  • [26] Cone-Beam CT: Vascular Applications
    Angle, John F.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 16 (03) : 144 - 149
  • [27] A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.
    von Berg, J.
    Lorenz, C.
    Grass, M.
    MEDICAL PHYSICS, 2008, 35 (07) : 3239 - 3251
  • [28] Planning Evaluation of Cone-beam CT Angiography for Target Delineation in Stereotactic Radiosurgery of AVMs
    Kang, J.
    Huang, J.
    Gailloud, P.
    Rigamonti, D.
    Bernard, V.
    Ehtiati, T.
    Ford, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S770 - S771
  • [29] Cone-beam volume CT breast imaging: Feasibility study
    Chen, B
    Ning, R
    MEDICAL PHYSICS, 2002, 29 (05) : 755 - 770
  • [30] Reconstruction-of-difference (RoD) imaging for cone-beam CT neuro-angiography
    Wu, P.
    Stayman, J. W.
    Mow, M.
    Zbijewski, W.
    Sisniega, A.
    Aygun, N.
    Stevens, R.
    Foos, D.
    Wang, X.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (11):