Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia

被引:13
|
作者
Liu, Yongji [1 ]
Wang, Yan [2 ]
Wang, Zhaoqi [1 ]
Zuo, Tong [2 ]
机构
[1] Nankai Univ, Minist Educ, Key Lab Opt Informat Sci & Technol, Inst Modern Opt, Tianjin 300071, Peoples R China
[2] Tianjin Eye Hosp, Refract Surg Ctr, Tianjin, Peoples R China
基金
美国国家科学基金会;
关键词
corneal power; intraocular lens; measurement error; refractive surgery; INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; PHOTOREFRACTIVE KERATECTOMY; ASPHERICITY; PENTACAM; LASIK;
D O I
10.1111/j.1475-1313.2012.00921.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32, 355361. doi: 10.1111/j.1475-1313.2012.00921.x Abstract Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 1839 years). The radius of curvature of anterior and posterior corneal surface, Q-Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power Fg, back vertex power Fv, and keratometric power SimK, were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 +/- 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (-0.21 +/- 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 +/- 0.11 D. With the Q-value changing from -0.09 to -0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 +/- 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 +/- 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 +/- 0.40 D. With the Q-value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [31] Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Eyes With Previous Myopic Laser Refractive Surgery
    Camps, Vicente J.
    Pinero, David P.
    Mateo, Veronica
    Ribera, David
    de Fez, Dolores
    Blanes-Mompo, Francisco J.
    Alzamora-Rodriguez, Antonio
    CORNEA, 2013, 32 (11) : 1454 - 1459
  • [32] Corneal power after refractive surgery for myopia: Contact lens method (vol 29, pg 1397, 2003)
    不详
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10): : 1854 - 1854
  • [33] Intraocular lens power calculation after laser refractive surgery Corrective algorithm for corneal power estimation
    Jin, Haiying
    Holzer, Mike P.
    Rabsilber, Tanja
    Borkenstein, Andreas F.
    Lirnberger, Ii-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (01): : 87 - 96
  • [34] Comparison of Corneal Power and Astigmatism between Simulated Keratometry, True Net Power, and Total Corneal Refractive Power before and after SMILE Surgery
    Qian, Yishan
    Liu, Yan
    Zhou, Xingtao
    Naidu, Rajeev Krishnan
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [35] Estimation of corneal power after myopic laser refractive surgery: Comparison of methods against back-calculated corneal power
    Tay, Eugene
    Lim, Cindy
    Gimbel, Howard
    Kaye, Geoffrey
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 1945 - 1950
  • [36] Power calculation after laser refractive surgery
    Rosa, Nicola
    Capasso, Luigi
    Lanza, Michele
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1653 - 1653
  • [37] MEASUREMENT OF CORNEAL CURVATURE AFTER EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY
    CHARLES, KC
    THOMPSON, KP
    STULTING, RD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 804 - 804
  • [38] Calculating intraocular lens power after refractive corneal surgery
    Hoffer, KJ
    Monica, S
    ARCHIVES OF OPHTHALMOLOGY, 2002, 120 (04) : 500 - 501
  • [39] Intraocular Lens Power Calculation After Corneal Refractive Surgery
    Feiz, Vahid
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2010, 17 (01) : 63 - 68
  • [40] Calculation of intraocular lens power after corneal refractive surgery
    Chan, Colin C. K.
    Hodge, Chris
    Lawless, Michael
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (07): : 640 - 644