Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia

被引:13
|
作者
Liu, Yongji [1 ]
Wang, Yan [2 ]
Wang, Zhaoqi [1 ]
Zuo, Tong [2 ]
机构
[1] Nankai Univ, Minist Educ, Key Lab Opt Informat Sci & Technol, Inst Modern Opt, Tianjin 300071, Peoples R China
[2] Tianjin Eye Hosp, Refract Surg Ctr, Tianjin, Peoples R China
基金
美国国家科学基金会;
关键词
corneal power; intraocular lens; measurement error; refractive surgery; INTRAOCULAR-LENS POWER; IN-SITU KERATOMILEUSIS; PHOTOREFRACTIVE KERATECTOMY; ASPHERICITY; PENTACAM; LASIK;
D O I
10.1111/j.1475-1313.2012.00921.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Citation information: Liu Y, Wang Y, Wang Z & Zuo T. Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia. Ophthalmic Physiol Opt 2012, 32, 355361. doi: 10.1111/j.1475-1313.2012.00921.x Abstract Purpose: To investigate the sources of error in corneal power measurement before and after corneal refractive surgery for myopia. Methods: The study comprised 28 eyes of six males and eight females with a mean age of 26 (range 1839 years). The radius of curvature of anterior and posterior corneal surface, Q-Values of anterior and posterior corneal surface and corneal central thickness were measured by rotating Scheimpflug imaging (Pentacam). The true net power Fg, back vertex power Fv, and keratometric power SimK, were calculated respectively at the apex and at a paracentral area on the 3 mm ring. Results: For virgin eyes, the overestimation (0.53 +/- 0.11 D) of the corneal power by using a keratometric index of 1.3375 was balanced by the underestimation (-0.21 +/- 0.09 D) of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error with a mean value of 0.33 +/- 0.11 D. With the Q-value changing from -0.09 to -0.41, the percentage balanced by the error in radius of curvature increased from 16% to 73%. However, for eyes after laser refractive surgery, the radius of curvature error lead to an overestimation (0.54 +/- 0.16 D) of the corneal power and the keratometric index of 1.3375 again overestimated (1.59 +/- 0.26 D) the corneal power, resulting in a large measurement error with a mean value of 2.12 +/- 0.40 D. With the Q-value changing from 0.35 to 1.89, the percentage added by the error in radius of curvature increased from 14% to 32%. Conclusions: For virgin eyes, the overestimation of the corneal power by using a keratometric index of 1.3375 is balanced by the underestimation of the corneal power by the error in the radius of curvature, resulting in a relatively small corneal power error. However, for eyes after laser refractive surgery, the flatter anterior corneal surface means that the use of a keratometric index of 1.3375 significantly overestimates the corneal power and the radius of curvature error now adds to this overestimation and results in a large measurement error.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 50 条
  • [21] Trifocal diffractive intraocular lens implantation in patients after previous corneal refractive laser surgery for myopia
    Qiu-Mei Li
    Feng Wang
    Zhe-Ming Wu
    Zhen Liu
    Chuan Zhan
    Bing-Heng Chen
    Jing Sima
    Knut Stieger
    Shao-Wei Li
    BMC Ophthalmology, 20
  • [22] Corneal Epithelium Thickness and Refractive Changes After Myopic Laser Corneal Refractive Surgery
    Canto-Cerdan, Mario
    El Bahrawy, Mohamed
    Alio, Jorge L.
    Casanova, Laura
    Garcia, Maria J.
    Al-Amri, Saad Abdulrahman J.
    Cavas, Francisco
    Alio del Barrio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (09) : 602 - +
  • [23] Implantable collamer lens for residual refractive error after corneal refractive surgery
    Chen, Xun
    Wang, Xiao-Ying
    Zhang, Xi
    Chen, Zhi
    Zhou, Xing-Tao
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (10) : 1421 - 1426
  • [24] Implantable collamer lens for residual refractive error after corneal refractive surgery
    Xun Chen
    Xiao-Ying Wang
    Xi Zhang
    Zhi Chen
    Xing-Tao Zhou
    International Journal of Ophthalmology, 2016, (10) : 1421 - 1426
  • [25] Calculations of actual corneal astigmatism using total corneal refractive power before and after myopic keratorefractive surgery
    Seo, Kyoung Yul
    Yang, Hun
    Kim, Wook Kyum
    Nam, Sang Min
    PLOS ONE, 2017, 12 (04):
  • [26] Microbial keratitis after corneal laser refractive surgery
    Sharma, Daya Papalkar
    Sharma, Shanel
    Wilkins, Mark R.
    FUTURE MICROBIOLOGY, 2011, 6 (07) : 819 - 831
  • [27] Biomechanical effects on the corneal surface shape after refractive laser surgery.
    Schruender, SA
    Genth, UP
    Huebscher, HJ
    Dankert, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S606 - S606
  • [28] IOL Power Calculation after Corneal Refractive Surgery
    De Bernardo, Maddalena
    Capasso, Luigi
    Caliendo, Luisa
    Paolercio, Francesco
    Rosa, Nicola
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [29] IOL power calculation after corneal refractive surgery
    Rosa, Nicola
    Capasso, Luigi
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (08) : 735 - 735
  • [30] Disparity between keratometry-style readings and corneal power within the pupil after refractive surgery for myopia
    Maeda, N
    Klyce, SD
    Smolek, MK
    McDonald, MB
    CORNEA, 1997, 16 (05) : 517 - 524