Intracardiac vs transesophageal echocardiography for percutaneous left atrial appendage occlusion: A meta-analysis

被引:40
|
作者
Velagapudi, Poonam [1 ]
Turagam, Mohit K. [2 ]
Kolte, Dhaval [3 ]
Khera, Sahil [1 ]
Gupta, Tanush [5 ]
Garg, Jalaj [2 ]
Abbott, J. Dawn [3 ]
George, Isaac [1 ]
Khalique, Omar [1 ]
Vahl, Torsten [1 ]
Nazif, Tamim [1 ]
Lakkireddy, Dhanunjaya [4 ]
Kodali, Susheel [1 ]
Sommer, Robert [1 ]
机构
[1] Columbia Univ, Med Ctr, Div Cardiol, Struct Heart & Valve Ctr,Ctr Intervent Vasc Thera, New York, NY 10032 USA
[2] Icahn Sch Med Mt Sinai, Helmsley Ctr Cardiac Electrophysiol, New York, NY 10029 USA
[3] Brown Univ, Div Cardiovasc Med, Providence, RI 02912 USA
[4] Kansas City Heart Rhythm Inst & Res Fdn, Overland Pk, KS USA
[5] Montefiore Med Ctr, Albert Einstein Coll Med, Div Cardiovasc Med, 111 E 210th St, Bronx, NY 10467 USA
关键词
ACP; Amulet; intracardiac echo; left atrial appendage closure; meta-analysis; stroke prevention; transesophageal echocardiography; Watchman; GUIDANCE;
D O I
10.1111/jce.13820
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Percutaneous left atrial appendage closure (LAAC) is typically performed utilizing transesophageal echocardiography (TEE) and fluoroscopy. Intracardiac echocardiography (ICE) can be a suitable alternative to guide implantation. Given the limited data, we performed a meta-analysis of all studies that compared ICE vs TEE for percutaneous LAAC. Methods A comprehensive literature search was performed in PubMed, Embase, Scopus, Google Scholar, and major scientific conference sessions for published abstracts and manuscripts until 1 August 2018. Studies reporting clinical outcomes comparing TEE vs ICE for endocardial LAAC in human subjects aged greater than or equal to 18 years were included. Two investigators independently extracted the data and individual quality assessment was performed. The analysis was performed using Cochrane Collaboration software, RevMan 5.3. Results Five eligible studies consisting of 1157 patients (ICE-391 patients and TEE-766 patients) were included. Four studies were retrospective and one was prospective, nonrandomized. Two studies included Watchman, two included the Amplatzer Cardiac Plug/Amulet device, and one included both devices. There was no significant difference in CHA2DS2VASC or HAS-BLED scores between both groups. There was no significant difference in acute procedural success between ICE vs TEE (risk ratio, 1.01; 95% CI, 0.99-1.04; P = 0.24). There was no significant difference in fluoroscopy time (mean difference [MD], 1.84 minutes; 95% CI, 0.59-4.27; P = 0.14) and total procedure time (MD, -5.06 minutes; 95% CI, -24.6-14.4; P = 0.61) between both groups. There was also no significant difference in complications including pericardial tamponade, device embolization, and stroke between both groups. Conclusion In our meta-analysis, ICE was as effective as TEE during percutaneous LAAC.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 50 条
  • [41] A Comparative Meta-Analysis of Newer Percutaneous Left Atrial Appendage Occlusion Devices
    Gill, Gauravpal Singh
    Sanz Sanchez, Jorge
    Sanchez-Martinez, Jose Carlos
    Ponna, Pramod Kumar
    Kanmanthareddy, Arun
    Alla, Venkata M.
    Garcia-Garcia, Hector
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B155 - B156
  • [42] Three-dimensional intracardiac echocardiography for left atrial appendage sizing and percutaneous occlusion guidance
    Della Rocca, Domenico G.
    Magnocavallo, Michele
    Gianni, Carola
    Mohanty, Sanghamitra
    Al-Ahmad, Amin
    Bassiouny, Mohamed
    Denora, Marialessia
    La Fazia, Vincenzo Mirco
    Lavalle, Carlo
    Gallinghouse, Gerald J.
    Santangeli, Pasquale
    Polselli, Marco
    Sarkozy, Andrea
    Vetta, Giampaolo
    Ahmed, Adnan
    Sanchez, Javier E.
    Pannone, Luigi
    Chierchia, Gian-Battista
    Tschopp, David R.
    de Asmundis, Carlo
    Di Biase, Luigi
    Lakkireddy, Dhanunjaya
    Burkhardt, David J.
    Horton, Rodney P.
    Natale, Andrea
    EUROPACE, 2023, 26 (01):
  • [43] Comparison of transesophageal and intracardiac echocardiography in guiding percutaneous left atrial appendage closure with an Amplatzer Amulet device
    Streb, Witold
    Mitrega, Katarzyna
    Podolecki, Tomasz
    Morawski, Stanislaw
    Szulik, Mariola
    Jedrzejczyk-Patej, Ewa
    Kukulski, Tomasz
    Kalarus, Zbigniew
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2019, 15 (04): : 446 - 454
  • [44] Outcomes of Routine Intracardiac Echocardiography to Guide Left Atrial Appendage Occlusion
    Alkhouli, Mohamad
    Chaker, Zakeih
    Alqahtani, Fahad
    Raslan, Saleem
    Raybuck, Bryan
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (04) : 393 - 400
  • [45] OUTCOMES OF PERCUTANEOUS LEFT ATRIAL APPENDAGE OCCLUSION (LAAO) ON LEFT ATRIAL FUNCTION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Torres, Rosa N. Cruz
    Bansal, Raahat
    Thandra, Abhishek
    Ponamgi, Shiva
    Alla, Venkata Mahesh
    Aboeata, Ahmed Salah Ahmed
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1284 - 1284
  • [46] Residual leaks following percutaneous left atrial appendage occlusion and outcomes: a meta-analysis
    Samaras, Athanasios
    Papazoglou, Andreas S.
    Balomenakis, Charalampos
    Bekiaridou, Alexandra
    Moysidis, Dimitrios, V
    Patsiou, Vasiliki
    Orfanidis, Antonios
    Giannakoulas, George
    Kassimis, George
    Fragakis, Nikolaos
    Saw, Jacqueline
    Landmesser, Ulf
    Alkhouli, Mohamad Adnan
    Tzikas, Apostolos
    EUROPEAN HEART JOURNAL, 2024, 45 (03) : 214 - 229
  • [47] Echocardiography in Percutaneous Left Atrial Appendage Occlusion and Related Complications
    Thakker, Ravi
    Faluk, Mohammed Ali
    Modi, Shreyas
    Ahmad, Masood
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2023, 40 (12): : 1325 - 1335
  • [48] Transnasal Transesophageal Echocardiography Guidance for Percutaneous Left Atrial Appendage Closure
    Wang, Bin
    Zhang, Li
    Sun, Wei
    He, Lin
    Wang, Xinfang
    Lv, Qing
    Li, Yuman
    Xie, Mingxing
    ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E161 - E164
  • [49] Left atrial appendage closure with the Watchman device using intracardiac vs transesophageal echocardiography: Procedural and cost considerations
    Hemam, Majd E.
    Kuroki, Kenji
    Schurmann, Paul A.
    Dave, Amish S.
    Rodriguez, Diego A.
    Saenz, Luis C.
    Reddy, Vivek Y.
    Valderrabano, Miguel
    HEART RHYTHM, 2019, 16 (03) : 334 - 342
  • [50] REPLY: Intracardiac Echocardiography From the Left Atrium to Guide Left Atrial Appendage Occlusion
    Nielsen-Kudsk, Jens Erik
    Berti, Sergio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (19) : 1984 - 1985