Comparison of transesophageal and intracardiac echocardiography in guiding percutaneous left atrial appendage closure with an Amplatzer Amulet device

被引:9
|
作者
Streb, Witold [1 ]
Mitrega, Katarzyna [1 ]
Podolecki, Tomasz [1 ]
Morawski, Stanislaw [1 ]
Szulik, Mariola [1 ]
Jedrzejczyk-Patej, Ewa [1 ]
Kukulski, Tomasz [1 ]
Kalarus, Zbigniew [1 ]
机构
[1] Med Univ Silesia, Silesian Ctr Heart Dis Zabrze, Dept Cardiol Congenital Heart Dis & Electrotherap, 2 Szpitalna St, PL-41800 Zabrze, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2019年 / 15卷 / 04期
关键词
transesophageal echocardiography; left atrial appendage occlusion; intracardiac echocardiography; TRANSCATHETER CLOSURE; OCCLUSION; GUIDANCE; FIBRILLATION; THROMBI;
D O I
10.5114/aic.2019.90219
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Percutaneous occlusion of the left atrial appendage (LAAO) is becoming an extensively used method of stroke prevention in individuals with contraindications to oral anticoagulants. Transesophageal echocardiography (TOE) is the gold standard for LAAO guiding, but intracardiac echocardiography (ICE) appears to be a potential alternative. Aim: To compare the LAAO procedure guided by TOE or ICE with respect to procedural success and safety. Material and methods: TOE-guided LAAO was performed in 12 patients and ICE-guided LAAO in 11 patients. ICE was performed using an 8F AcuNav probe and the ACUSON SC2000 system. For LAAO the Amplatzer Amulet was used. After 1 month TOE was performed. Results: Procedural success was achieved in all patients in TOE and ICE groups. There was 1 complication (groin hematoma). The procedure time was significantly longer in the TOE group (43 to 80 min; median: 54 min) compared to the ICE group (28 to 67 min; median: 45 min), (p = 0.02) The time needed to puncture the interatrial septum and time needed to remove the sheath did not differ between groups. Fluoroscopic time was insignificantly longer in the ICE group (9.91 +/- 4.01s) compared to the TOE group (7.69 +/- 3.21s), and a significantly larger contrast media volume was used in the ICE group (30.00 +/- 6.67 ml vs. 40.45 +/- 23.18 ml, p = 0.03). There were no statistically significant differences in the results between TOE and ICE groups in follow-up assessments. Conclusions: LAAO using the Amplatzer Amulet may be successfully and safely guided by ICE. ICE offered shorter procedure time and similar results irrespectively of left atrial appendage anatomy compared to TOE guidance.
引用
收藏
页码:446 / 454
页数:9
相关论文
共 50 条
  • [1] Percutaneous Closure of a Very Large Left Atrial Appendage Using the Amplatzer Amulet
    Freixa, Xavier
    Chan, Jason Leung Kwai
    Tzikas, Apostolos
    Garceau, Patrick
    Basmadjian, Arsene
    Ibrahim, Reda
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : 1329.e9 - 1329.e11
  • [2] Intracardiac echocardiography is a promising strategy for guiding closure of the left atrial appendage
    Ding, Xueyan
    Xiang, Kefa
    Qian, Congli
    Hou, Xu
    Wu, Feng
    [J]. HEALTH SCIENCE REPORTS, 2023, 6 (12)
  • [3] AMPLATZER Amulet Observational Study of Left Atrial Appendage Occlusion: Use of Intracardiac and Transophageal Echocardiography
    Schmidt, Boris
    Bella, Paolo D.
    Nielsen-Kudsk, Jens E.
    Zeus, Tobias
    Omran, Heyder
    Berti, Sergio
    Soendergaard, Lars
    Aguirre, Daniel
    Tondo, Claudio
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) : 576 - 577
  • [4] Left Atrial Appendage Closure Under Intracardiac Echocardiographic Guidance: Feasibility and Comparison With Transesophageal Echocardiography
    Matsuo, Yae
    Neuzil, Petr
    Petru, Jan
    Chovanec, Milan
    Janotka, Marek
    Choudry, Subbarao
    Skoda, Jan
    Sediva, Lucie
    Kurabayashi, Masahiko
    Reddy, Vivek Y.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (10):
  • [5] Use of Intracardiac Compared With Transesophageal Echocardiography for Left Atrial Appendage Occlusion in the Amulet Observational Study
    Nielsen-Kudsk, Jens Erik
    Berti, Sergio
    De Backer, Ole
    Aguirre, Daniel
    Fassini, Gaetano
    Cruz-Gonzalez, Ignacio
    Grassi, Giuseppi
    Tondo, Claudio
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (11) : 1030 - 1039
  • [6] Can intracardiac echocardiography completely replace transesophageal echocardiography to guide left atrial appendage closure?-The comparisons of intracardiac echocardiography with transesophageal echocardiography
    Ge, Junye
    Chen, Tongshuai
    Ma, Chuanzhen
    Maduray, Kellina
    Zhong, Jingquan
    [J]. JOURNAL OF CARDIAC SURGERY, 2022, 37 (09) : 2766 - 2775
  • [7] Transnasal Transesophageal Echocardiography Guidance for Percutaneous Left Atrial Appendage Closure
    Wang, Bin
    Zhang, Li
    Sun, Wei
    He, Lin
    Wang, Xinfang
    Lv, Qing
    Li, Yuman
    Xie, Mingxing
    [J]. ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E161 - E164
  • [8] First case of percutaneous left atrial appendage closure by amulet™ device in a patient with left atrial appendage thrombus
    Aytemir, Kudret
    Aminian, Adel
    Asil, Serkan
    Canpolat, Ugur
    Kaya, Ergun Baris
    Sahiner, Levent
    Evranos, Banu
    Yorgun, Hikmet
    Ozer, Necla
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 28 - 30
  • [9] Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: a systematic review and meta-analysis
    Jaiswal, Vikash
    Ang, Song P.
    Shrestha, A. B.
    Sharma, Prachi
    Endurance, E. O.
    Khan, Shazia
    Mukherjee, D.
    Jaiswal, Akash
    Chia, Jia E. E.
    Huang, Helen
    Alraies, M. C.
    Biswas, M.
    [J]. EUROPEAN HEART JOURNAL, 2023, 44 : 19 - 20
  • [10] Amplatzer amulet versus watchman device for percutaneous left atrial appendage closure: A systematic review and meta-analysis
    Jaiswal, Vikash
    Ang, Song Peng
    Shrestha, Abhigan Babu
    Wajid, Zarghoona
    Endurance, Evbayekha Osas
    Ayoobkhan, Fathima Shehnaz
    Khan, Shazia
    Garimellla, Vamsi
    Huang, Helen
    Ghanim, Mohammed
    Song, David
    Sharma, Prachi
    Alraies, M. Chadi
    Biswas, Monodeep
    [J]. MEDICINE, 2023, 102 (26) : E34185