Energy and exergy analysis of a 747-MW combined cycle power plant Guddu

被引:42
|
作者
Ali, Mir Sikander [1 ]
Shafique, Qadir Nawaz [1 ]
Kumar, Dileep [1 ,2 ]
Kumar, Summeet [1 ]
Kumar, Sanjay [1 ,2 ]
机构
[1] Mehran Univ Engn & Technol, Dept Mech Engn, Shaheed Zulfiqar Ali Bhutto Campus, Khairpur Mirs, Pakistan
[2] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei, Taiwan
关键词
Energy analysis; exergy analysis; combined cycle power plant; HRSG; efficiency; TURBINE; PERFORMANCE;
D O I
10.1080/01430750.2018.1517680
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper presents a detailed study based on the energy and exergy analysis of a combined cycle power plant (CCPP) Guddu having triple pressure heat recovery steam generator (HRSG). The energy loss and the energy efficiency of each plant component with HRSG as a whole is calculated. The exergy destruction of these components and the sub-parts of the HRSG are also found out. All the three stages of the steam turbine are analysed individually. The combustion chamber is found to have the maximum share of exergy destruction while the condenser is having a maximum of energy loss. The total net power output, energy and exergy efficiency of the whole plant is calculated as 737.8 MW, 59.12% and 58.24%, respectively. The error in getting the designed power output of 747 MW is 3.16%. The thermal efficiency of the Brayton and Rankine cycle is 62.01% and 56.38%, respectively.
引用
收藏
页码:1495 / 1504
页数:10
相关论文
共 50 条
  • [31] Exergy Analysis of a Combined Power and Cooling Cycle
    Karaali, R.
    ACTA PHYSICA POLONICA A, 2016, 130 (01) : 209 - 213
  • [32] Exergy analysis of a combined power and cooling cycle
    Fontalvo, Armando
    Pinzon, Horacio
    Duarte, Jorge
    Bula, Antonio
    Gonzalez Quiroga, Arturo
    Vasquez Padilla, Ricardo
    APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) : 164 - 171
  • [33] Sensitivity analysis of exergy destruction in a real combined cycle power plant based on advanced exergy method
    Boyaghchi, Fateme Ahmadi
    Molaie, Hanieh
    ENERGY CONVERSION AND MANAGEMENT, 2015, 99 : 374 - 386
  • [34] Thermodynamics Performance Evaluation in Combined Cycle Power Plant by Using Combined Pinch and Exergy Analysis
    Riady, M. I.
    Santoso, D.
    Bustan, M. D.
    SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018), 2019, 1198
  • [35] Exergoenvironmental optimization of Heat Recovery Steam Generators in combined cycle power plant through energy and exergy analysis
    Kaviri, Abdolsaeid Ganjeh
    Jaafar, Mohammad Nazri Mohd.
    Lazim, Tholudin Mat
    Barzegaravval, Hassan
    ENERGY CONVERSION AND MANAGEMENT, 2013, 67 : 27 - 33
  • [36] The energy and exergy analysis of a combined parabolic solar dish - steam power plant
    Basem, Ali
    Moawed, Mohammed
    Abbood, Mohammed H.
    El-Maghlany, Wael M.
    RENEWABLE ENERGY FOCUS, 2022, 41 : 55 - 68
  • [37] Combined pinch and exergy analysis for energy efficiency optimization in a steam power plant
    Ataei, Abtin
    Yoo, ChangKyoo
    INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2010, 5 (07): : 1110 - 1123
  • [38] Energy and Exergy Analyses of a Natural Gas Fired Combined Cycle Power Plant: Parametric Study
    Kilic, Ahmed Emin
    Arcaklioglu, Erol
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (02): : 721 - 730
  • [39] Energy and exergy analysis of an absorption power cycle
    Garcia-Hernando, Nestor
    de Vega, M.
    Soria-Verdugo, Antonio
    Sanchez-Delgado, Sergio
    APPLIED THERMAL ENGINEERING, 2013, 55 (1-2) : 69 - 77
  • [40] A novel geothermal combined cooling and power cycle based on the absorption power cycle: Energy, exergy and exergoeconomic analysis
    Parikhani, Towhid
    Ghaebi, Hadi
    Rostamzadeh, Hadi
    ENERGY, 2018, 153 : 265 - 277