Development of a fluorescent optical potassium-selective ion sensor with ratiometric response for intracellular applications

被引:50
|
作者
Shortreed, MR [1 ]
Dourado, S [1 ]
Kopelman, R [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
基金
美国国家卫生研究院;
关键词
optodes; optrodes; BME-44; fiber-optic;
D O I
10.1016/S0925-4005(97)80166-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A small, fluorescent fiber-optic potassium sensor is described with a working range which covers both intracellular cytosolic and blood levels of potassium at the respective physiological pH values. The highly potassium-selective ionophore, BME-44, is retained in a plasticized poly(vinyl chloride) (PVC) Nm which is placed on the end of an optical fiber. Three optode configurations are given, employing different lipophilic, fluorescent pH chromoionophores (Nile Blue derivatives), demonstrating the ability to improve the detection limit and tune the dynamic range to the desired region of interest. These optodes also have excellent selectivity over sodium, calcium and magnesium Use of fluorescence (in contrast to absorbance) provides a means to reduce the sensor size dramatically while retaining the same signal-to-noise ratio. These optodes measure the sample's potassium activity (rather than concentration) provided that the sample's pH is measured simultaneously by another sensor, such as a glass pH electrode.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [1] Potassium-selective conductometric sensor
    Shvarev, AE
    Rantsan, DA
    Mikhelson, KN
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 500 - 505
  • [2] Rhodamine based NIR and ratiometric fluorescent sensor for selective identification of potassium ion: application in biological sample
    Kaur, Rajinder
    Sahoo, Suban Kumar
    Kuwar, Anil
    Kaur, Navneet
    Singh, Narinder
    SUPRAMOLECULAR CHEMISTRY, 2019, 31 (01) : 36 - 44
  • [3] A highly potassium-selective ratiometric fluorescent indicator based on BODIPY azacrown ether excitable with visible light
    Baruah, M
    Qin, WW
    Vallée, RAL
    Beljonne, D
    Rohand, T
    Dehaen, W
    Boens, N
    ORGANIC LETTERS, 2005, 7 (20) : 4377 - 4380
  • [4] Development of a potassium ion-selective fluorescent sensor based on 3-styrylated BODIPY
    Hirata, Tomoya
    Terai, Takuya
    Komatsu, Toru
    Hanaoka, Kenjiro
    Nagano, Tetsuo
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2011, 21 (20) : 6090 - 6093
  • [5] THE EFFECT OF HEPARIN COATING ON THE RESPONSE OF POTASSIUM-SELECTIVE ELECTRODES
    BROOKS, KA
    ALLEN, JR
    FELDHOFF, P
    BACHAS, LG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 18 - ANYL
  • [6] A selective fluorescent ratiometric chemodosimeter for mercury ion
    Liu, B
    Tian, H
    CHEMICAL COMMUNICATIONS, 2005, (25) : 3156 - 3158
  • [7] Design of Potassium-Selective Mixed Ion/Electron Conducting Polymers
    Villarroel Marquez, Ariana
    Salinas, Gerardo
    Abarkan, Myriam
    Idir, Mael
    Brochon, Cyril
    Hadziioannou, Georges
    Raoux, Matthieu
    Kuhn, Alexander
    Lang, Jochen
    Cloutet, Eric
    MACROMOLECULAR RAPID COMMUNICATIONS, 2020, 41 (12)
  • [8] A selective, ratiometric fluorescent sensor for Pb2+
    Deo, S
    Godwin, HA
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (01) : 174 - 175
  • [9] Selective, ratiometric fluorescent sensor for Pb2+.
    Godwin, HA
    Deo, S
    Fowler, DM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U873 - U873
  • [10] Improved potassium-selective membrane using valinomycin as ionophore for ion-selective microdevices
    Totu, E
    Josceanu, AM
    Covington, AK
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2001, 18 (1-2): : 87 - 91