Development of a fluorescent optical potassium-selective ion sensor with ratiometric response for intracellular applications

被引:50
|
作者
Shortreed, MR [1 ]
Dourado, S [1 ]
Kopelman, R [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
基金
美国国家卫生研究院;
关键词
optodes; optrodes; BME-44; fiber-optic;
D O I
10.1016/S0925-4005(97)80166-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A small, fluorescent fiber-optic potassium sensor is described with a working range which covers both intracellular cytosolic and blood levels of potassium at the respective physiological pH values. The highly potassium-selective ionophore, BME-44, is retained in a plasticized poly(vinyl chloride) (PVC) Nm which is placed on the end of an optical fiber. Three optode configurations are given, employing different lipophilic, fluorescent pH chromoionophores (Nile Blue derivatives), demonstrating the ability to improve the detection limit and tune the dynamic range to the desired region of interest. These optodes also have excellent selectivity over sodium, calcium and magnesium Use of fluorescence (in contrast to absorbance) provides a means to reduce the sensor size dramatically while retaining the same signal-to-noise ratio. These optodes measure the sample's potassium activity (rather than concentration) provided that the sample's pH is measured simultaneously by another sensor, such as a glass pH electrode.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 50 条
  • [31] POTASSIUM-SELECTIVE ION CHANNELS IN A TRANSFORMED INSULIN-SECRETING CELL-LINE
    LIGHT, DB
    VANEENENAAM, DP
    SORENSON, RL
    LEVITT, DG
    JOURNAL OF MEMBRANE BIOLOGY, 1987, 95 (01): : 63 - 72
  • [32] AN OPTICAL POTASSIUM-ION SENSOR
    ALDER, JF
    ASHWORTH, DC
    NARAYANASWAMY, R
    MOSS, RE
    SUTHERLAND, IO
    ANALYST, 1987, 112 (08) : 1191 - 1192
  • [33] A light-gated, potassium-selective glutamate receptor for the optical inhibition of neuronal firing
    Janovjak, Harald
    Szobota, Stephanie
    Wyart, Claire
    Trauner, Dirk
    Isacoff, Ehud Y.
    NATURE NEUROSCIENCE, 2010, 13 (08) : 1027 - U160
  • [34] Potassium-selective atomic force microscopy on ion-releasing substrates and living cells
    Schär-Zammaretti, P
    Ziegler, U
    Forster, I
    Groscurth, P
    Spichiger-Keller, UE
    ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4269 - 4274
  • [35] A light-gated, potassium-selective glutamate receptor for the optical inhibition of neuronal firing
    Harald Janovjak
    Stephanie Szobota
    Claire Wyart
    Dirk Trauner
    Ehud Y Isacoff
    Nature Neuroscience, 2010, 13 : 1027 - 1032
  • [36] Novel resorcin[4]arenes as potassium-selective ion-channel and transporter mimics
    Wright, AJ
    Matthews, SE
    Fischer, WB
    Beer, PD
    CHEMISTRY-A EUROPEAN JOURNAL, 2001, 7 (16) : 3474 - 3481
  • [37] ION-SELECTIVE ELECTRODE FOR INTRACELLULAR POTASSIUM MEASUREMENTS
    HAEMMERLI, A
    JANATA, J
    BROWN, HM
    ANALYTICAL CHEMISTRY, 1980, 52 (08) : 1179 - 1182
  • [38] A Light-Gated, Potassium-Selective Glutamate Receptor for the Optical Inhibition of Neuronal Firing
    Janovjak, Harald
    Trauner, Dirk
    Isacoff, Ehud Y.
    BIOPHYSICAL JOURNAL, 2010, 98 (03) : 223A - 223A
  • [39] DEVELOPMENT OF A POLYIMIDE BASED POTASSIUM ION-SELECTIVE MEMBRANE FOR ISFET SENSOR
    LIAO, E
    AW, CY
    MOINPOUR, M
    MORGAN, C
    CHEUNG, PW
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 1128 - 1129
  • [40] A fluorescent sensor based on bicarboxamidoquinoline for highly selective relay recognition of Zn2+ and citrate with ratiometric response
    Tian, Xuhua
    Guo, Xiangfeng
    Jia, Lihua
    Yang, Rui
    Cao, Guangzhou
    Liu, Chaoyue
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 923 - 929