Improved potassium-selective membrane using valinomycin as ionophore for ion-selective microdevices

被引:14
|
作者
Totu, E
Josceanu, AM
Covington, AK
机构
[1] Univ Politechn Bucharest, Fac Ind Chem, Dept Analyt Chem & Instrumental Anal, Bucharest, Romania
[2] Univ Newcastle Upon Tyne, Dept Phys Chem, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
ionophore; KCl; potassium;
D O I
10.1016/S0928-4931(01)00374-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ion-selective field effect transistors (ISFETs) were tested for their suitability for clinical work. They were intended for use in the analysis of blood and serum, where the concentration of specific ions, e.g. sodium and potassium, is of critical importance. The optical sensitivity of ISFETs and a new membrane composition for use in the clinical chemistry were evaluated. ISFETs with a polyimide/valinomycin membrane were shown to operate satisfactorily in the presence of proteins, encouraging the further development of these ISFETs as clinical sensors. ETH 2041 (tetra-n-undecyl 3,3', 4,4'-benzophenone tetracarboxylate) and DGD (diethylene dibenzoate) were the plasticizers used and their performances were compared. Valinomycin was used as ionophore. The membranes were calibrated using the dip (solutions in the 10(-1)-10(-5) mol dm(-3) KO range) and the constant volume dilution methods. Both membrane compositions gave good Nernstian responses. The ETH 2041 plasticizer was found to yield devices more selective to potassium ion than the more easily usable DGD. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:87 / 91
页数:5
相关论文
共 50 条
  • [1] POTASSIUM ION-SELECTIVE LIQUID MEMBRANE
    BAND, DM
    KRATOCHV.J
    JOURNAL OF PHYSIOLOGY-LONDON, 1974, 239 (01): : P10 - P10
  • [2] A CHEAP ALTERNATIVE TO VALINOMYCIN FOR CERTAIN ANALYSES WITH THE POTASSIUM ION-SELECTIVE ELECTRODE
    CATTRALL, RW
    DEADY, LW
    TAN, SS
    HAMILTON, IC
    ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) : 283 - 286
  • [3] POTASSIUM-SELECTIVE HEMO-ANALYSIS USING THE VALINOMYCIN-DISC-ELECTRODE
    SCHINDLER, JG
    BIOMEDIZINISCHE TECHNIK, 1979, 24 (09): : 203 - 208
  • [4] REPLACEMENT ION CHROMATOGRAPHY WITH POTENTIOMETRIC DETECTION USING A POTASSIUM-SELECTIVE MEMBRANE-ELECTRODE
    TROJANOWICZ, M
    MEYERHOFF, ME
    ANALYTICA CHIMICA ACTA, 1989, 222 (01) : 95 - 107
  • [5] Potassium Ion Selective Electrode Using Polyaniline and Matrix-Supported Ion-Selective PVC Membrane
    Thuy Nguyen Thanh Tran
    Qiu, Shide
    Chung, Hyun-Joong
    IEEE SENSORS JOURNAL, 2018, 18 (22) : 9081 - 9087
  • [6] POTASSIUM ION-SELECTIVE ELECTRODES BASED ON VALINOMYCIN PVC OVERLAYERED SOLID SUBSTRATES
    DROR, M
    BERGS, EA
    RHODES, RK
    SENSORS AND ACTUATORS, 1987, 11 (01): : 23 - 36
  • [7] RELAXATION PROPERTIES OF MEMBRANOUS VALINOMYCIN-BASED POTASSIUM ION-SELECTIVE ELECTRODES
    FEDOTOV, NA
    ZARINSKII, VA
    KOLOTYRKINA, IJ
    KHITROV, LM
    LAZAREV, VG
    DOKLADY AKADEMII NAUK SSSR, 1980, 255 (03): : 666 - 669
  • [8] INFLUENCE OF CERTAIN FACTORS ON THE POTENTIAL OF AN ION-SELECTIVE POTASSIUM ELECTRODE BASED ON VALINOMYCIN
    FEDOTOV, NA
    KHITROV, LM
    KOLOTYRKINA, IY
    LAZAREV, VG
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1986, 41 (02): : 199 - 202
  • [9] Calix[4]tubes: A new class of potassium-selective ionophore
    Matthews, SE
    Schmitt, P
    Felix, V
    Drew, MGB
    Beer, PD
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (07) : 1341 - 1353
  • [10] THE ELECTRODE PROPERTIES OF POTASSIUM-SELECTIVE MEMBRANES CONTAINING DIFFERENT LEVELS OF VALINOMYCIN
    STEFANOVA, OK
    SUGLOBOVA, ED
    SOVIET ELECTROCHEMISTRY, 1979, 15 (11): : 1467 - 1470