On-line chemiluminescence detection for capillary lan analysis

被引:95
|
作者
Huang, B [1 ]
Li, JJ [1 ]
Zhang, L [1 ]
Cheng, JK [1 ]
机构
[1] WUHAN UNIV,DEPT CHEM,WUHAN 430072,PEOPLES R CHINA
关键词
D O I
10.1021/ac9511253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive chemiluminescence detection for capillary ion analysis has been developed, The new idea lies in using the chemiluminescence reagent luminol as a component of the separation electrolyte, thus preventing loss of the light signal where luminol and H2O2 are mixed in advance in conventional now injection analysis or ion chromatography chemiluminescence detection, Signal enhancement is achieved by sample stacking injection in the electrophoresis process, The detection limit (S/N = 3) of 20 zmol (5 x 10(-13) mol/L) for cobalt(II) is similar to 2 orders of magnitude better than the most sensitive results (1.7 x 10(-11) mol/L) reported so far, Detection limits are 2 amol, 80 amol, 740 amol, and 100 fmol for copper(II), nickel(II), iron(III), and manganese(II), respectively, The sensitivity is significantly better than that in the electrochemical detection and the commonly used UV detection in capillary ion analysis. The capillary electrophoresis-chemiluminescence detector has been used to separate five metal ions, cobalt(II), copper(II), nickel(II), iron(III), and manganese(II), within 8 min with an average theoretical plate number of 4.6 x 10(5).
引用
收藏
页码:2366 / 2369
页数:4
相关论文
共 50 条
  • [41] Chemiluminescence detection in capillary electrophoresis
    Huang, XJ
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 2000, 414 (1-2) : 1 - 14
  • [42] Chemiluminescence detection in capillary electrophoresis
    Campana, AMG
    Baeyens, WRG
    Zhao, YN
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (03) : A83 - A88
  • [43] CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    COLON, LA
    DADOO, R
    ZARE, RN
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 50 - ANYL
  • [44] Dialysis membrane sampler for on-line flow injection analysis/chemiluminescence-detection of peroxynitrite in biological samples
    Dai, K
    Vlessidis, AG
    Evmiridis, NP
    [J]. TALANTA, 2003, 59 (01) : 55 - 65
  • [45] On-line capillary electrophoresis FTIR detection for the separation and characterization of proteins
    Kulka, S.
    Quintas, G.
    Lendl, B.
    [J]. VIBRATIONAL SPECTROSCOPY, 2006, 42 (02) : 392 - 396
  • [46] On-Line Detection of Polymer Melt Flow Instabilities in a Capillary Rheometer
    Palza, H.
    Naue, I. F. C.
    Wilhelm, M.
    Filipe, S.
    Becker, A.
    Sunder, J.
    Goettfert, A.
    [J]. KGK-KAUTSCHUK GUMMI KUNSTSTOFFE, 2010, 63 (10): : 456 - 461
  • [47] Capillary electrophoresis of cardiolipin with on-line dye interaction and spectrophotometric detection
    Qi, LN
    Danielson, ND
    Dai, Q
    Lee, RM
    [J]. ELECTROPHORESIS, 2003, 24 (10) : 1680 - 1686
  • [48] Simultaneous, sensitive and selective on-line chemiluminescence determination of Cr(III) and Cr(VI) by capillary electrophoresis
    Yang, WP
    Zhang, ZJ
    Deng, W
    [J]. ANALYTICA CHIMICA ACTA, 2003, 485 (02) : 169 - 177
  • [49] Capillary electrophoresis with on-line enrichment for the analysis of biological samples
    Sentellas, S
    Puignou, L
    Galceran, MT
    [J]. JOURNAL OF SEPARATION SCIENCE, 2002, 25 (15-17) : 975 - 987
  • [50] ON-LINE PRECONCENTRATION IN CAPILLARY ELECTROPHORESIS FOR ANALYSIS OF AGROCHEMICAL RESIDUES
    Fang, Rou
    Yi, Ling-Xiao
    Shao, Yu-Xiu
    Zhang, Li
    Chen, Guan-Hua
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (10) : 1465 - 1497