On-line chemiluminescence detection for capillary lan analysis

被引:95
|
作者
Huang, B [1 ]
Li, JJ [1 ]
Zhang, L [1 ]
Cheng, JK [1 ]
机构
[1] WUHAN UNIV,DEPT CHEM,WUHAN 430072,PEOPLES R CHINA
关键词
D O I
10.1021/ac9511253
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive chemiluminescence detection for capillary ion analysis has been developed, The new idea lies in using the chemiluminescence reagent luminol as a component of the separation electrolyte, thus preventing loss of the light signal where luminol and H2O2 are mixed in advance in conventional now injection analysis or ion chromatography chemiluminescence detection, Signal enhancement is achieved by sample stacking injection in the electrophoresis process, The detection limit (S/N = 3) of 20 zmol (5 x 10(-13) mol/L) for cobalt(II) is similar to 2 orders of magnitude better than the most sensitive results (1.7 x 10(-11) mol/L) reported so far, Detection limits are 2 amol, 80 amol, 740 amol, and 100 fmol for copper(II), nickel(II), iron(III), and manganese(II), respectively, The sensitivity is significantly better than that in the electrochemical detection and the commonly used UV detection in capillary ion analysis. The capillary electrophoresis-chemiluminescence detector has been used to separate five metal ions, cobalt(II), copper(II), nickel(II), iron(III), and manganese(II), within 8 min with an average theoretical plate number of 4.6 x 10(5).
引用
收藏
页码:2366 / 2369
页数:4
相关论文
共 50 条
  • [21] On-line screening method for antioxidants by liquid chromatography with chemiluminescence detection
    Ogawa, A
    Arai, H
    Tanizawa, H
    Miyahara, T
    Toyo'oka, T
    [J]. ANALYTICA CHIMICA ACTA, 1999, 383 (03) : 221 - 230
  • [22] On-line generation of a colloidal manganese(IV) reagent for chemiluminescence detection
    Smith, Zoe M.
    Terry, Jessica M.
    Hindson, Christopher M.
    Barnett, Neil W.
    Francis, Paul S.
    [J]. MICROCHEMICAL JOURNAL, 2013, 111 : 67 - 73
  • [23] On-line monitoring of formaldehyde in water and air using chemiluminescence detection
    Song, ZH
    Hou, SA
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (09) : 807 - 817
  • [24] Detection of polyols by HPLC coupled with an on-line photochemical oxidation reactor and chemiluminescence detection
    Yamazaki, S
    Hara, K
    Yokota, K
    Ikegami, T
    Konari, D
    Saito, K
    [J]. HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (02): : 127 - 130
  • [25] On-line Fourier transform infrared detection in capillary electrophoresis
    Kölhed, M
    Hinsmann, P
    Svasek, P
    Frank, J
    Karlberg, B
    Lendl, B
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (15) : 3843 - 3848
  • [26] Use of on-line mass spectrometric detection in capillary electrochromatography
    Choudhary, G
    Apffel, A
    Yin, HF
    Hancock, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 85 - 101
  • [27] Capillary electrophoresis/electrochemical detection system with on-line deoxygenation
    Jin, WR
    Dong, Q
    Yu, DQ
    Ye, XY
    Li, W
    [J]. ELECTROPHORESIS, 2000, 21 (08) : 1540 - 1544
  • [28] LC analysis of biogenic polyamines in table olives using on-line dansylation and peroxyoxalate chemiluminescence detection
    M. Cobo
    M. Silva
    [J]. Chromatographia, 2000, 51 : 706 - 712
  • [29] LC analysis of biogenic polyamines in table olives using on-line dansylation and peroxyoxalate chemiluminescence detection
    Cobo, M
    Silva, M
    [J]. CHROMATOGRAPHIA, 2000, 51 (11-12) : 706 - 712
  • [30] On-line chemiluminescence determination protocatechuic aldehyde and protocatechuic acid in pharmaceutical preparations by capillary electrophoresis
    Han, S
    Liu, E
    Li, H
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (04) : 733 - 738