Response characteristics of new perchlorate selective PVC membrane electrode based on a tripodal benzimidazole derivative as a neutral carrier

被引:0
|
作者
Chandra, Sulekh [1 ]
Singh, Inderjeet [2 ]
Tomar, Praveen Kumar [1 ,2 ]
Malik, Amrita [1 ]
Kumar, Avdhesh [1 ]
机构
[1] Univ Delhi, Zakir Husain Delhi Coll, Dept Chem, JL Nehru Marg, New Delhi 110002, India
[2] CCR Coll, Dept Chem, Muzaffarnagar, Uttar Pradesh, India
关键词
Perchlorate selective electrode; PVC membrane; potentiometry; tris[2-(1-ethylbenzimidazolyl)]methylamine; FLOW-INJECTION; ION CHROMATOGRAPHY; COMPLEX; LIQUID; EXTRACTION; IONOPHORES; WATER;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The potentiometric response characteristics of a new perchlorate selective poly(vinyl chloride) membrane electrode based on a tripodal benzimidazole derivative - tris[2-(1-ethylbenzimidazolyl)]methylamine as ionophore was investigated. The electrode exhibited a Nernstian response to perchlorate ions over the activity range of 1.5 x 10(-7) to 1.0 x 10(-1) M with a limit of detection of 5.2 x 10(-8) M between pH range of 2.0-10.0, giving a relatively fast response and reversibility within 5 s. The selectivity coefficient was calculated using fixed interference method (FIM). The electrode worked well for nearly 3 months. The electrode can also be used in partially non-aqueous media having up to 25% (v/v) methanol, ethanol or acetone contents with no significant change in the value of slope or working concentration range. It was successfully applied for the direct determination of perchlorate content in water and human urine samples with satisfactory results.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [41] NEUTRAL CARRIER-BASED MAGNESIUM-SELECTIVE ELECTRODE
    SALEH, MB
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2): : 89 - 95
  • [42] Response characteristics of lead-selective membrane sensors based on a newly synthesized quinoxaline derivatives as neutral carrier ionophores
    Ayman H. Kamel
    Abeer M. El-Naggar
    Amina A. A. Argig
    Ionics, 2017, 23 : 3497 - 3506
  • [43] Response characteristics of lead-selective membrane sensors based on a newly synthesized quinoxaline derivatives as neutral carrier ionophores
    Kamel, Ayman H.
    El-Naggar, Abeer M.
    Argig, Amina A. A.
    IONICS, 2017, 23 (12) : 3497 - 3506
  • [44] New diamino compound as neutral ionophore for highly selective and sensitive PVC membrane electrode for Be2+ ion
    Soleymanpour, A
    Rad, NA
    Niknam, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02): : 740 - 746
  • [45] NEUTRAL CARRIER MEMBRANE-ELECTRODE BASED ON BINUCLEAR METALLOPORPHYRIN
    GAO, D
    LIU, D
    YU, RQ
    ZHENG, GD
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06): : 484 - 488
  • [46] New Fe(II) Ion-selective electrode based On N-Phenylaza-15-Crown-5 as neutral carrier in PVC matrix
    Aghaie, M.
    Giahi, M.
    Aghaie, H.
    Arvand, M.
    Pournaghdy, M.
    Yavari, F.
    DESALINATION, 2009, 247 (1-3) : 346 - 354
  • [47] New Ni(II) Ion-Selective Electrode Based on the N-S Schiff Base Ligand as Neutral Carrier in PVC Matrix
    Ma, Yu-Hua
    Yuan, Ruo
    Chai, Ya-Qin
    Wu, Xia
    Zhou, Wei
    Liu, Xin-Lu
    Deng, Fan
    ANALYTICAL LETTERS, 2009, 42 (15) : 2411 - 2429
  • [48] CATION-RESPONSE MECHANISM OF NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE MEMBRANES
    MORF, WE
    SIMON, W
    HELVETICA CHIMICA ACTA, 1986, 69 (05) : 1120 - 1131
  • [49] THIURAM MONOSULFIDES AS A NEUTRAL CARRIER FOR COPPER(II)-SELECTIVE MEMBRANE-ELECTRODE
    KAMATA, S
    BHALE, A
    UDA, T
    CHEMISTRY LETTERS, 1988, (08) : 1247 - 1248
  • [50] Studies of highly sensitive PVC membrane iodide selective electrode based on complexes of mercury(I) as neutral carriers
    Chai, YQ
    Xu, WJ
    Yuan, R
    Xu, L
    Jiang, F
    ACTA CHIMICA SINICA, 2004, 62 (13) : 1226 - 1229