Response characteristics of new perchlorate selective PVC membrane electrode based on a tripodal benzimidazole derivative as a neutral carrier

被引:0
|
作者
Chandra, Sulekh [1 ]
Singh, Inderjeet [2 ]
Tomar, Praveen Kumar [1 ,2 ]
Malik, Amrita [1 ]
Kumar, Avdhesh [1 ]
机构
[1] Univ Delhi, Zakir Husain Delhi Coll, Dept Chem, JL Nehru Marg, New Delhi 110002, India
[2] CCR Coll, Dept Chem, Muzaffarnagar, Uttar Pradesh, India
关键词
Perchlorate selective electrode; PVC membrane; potentiometry; tris[2-(1-ethylbenzimidazolyl)]methylamine; FLOW-INJECTION; ION CHROMATOGRAPHY; COMPLEX; LIQUID; EXTRACTION; IONOPHORES; WATER;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The potentiometric response characteristics of a new perchlorate selective poly(vinyl chloride) membrane electrode based on a tripodal benzimidazole derivative - tris[2-(1-ethylbenzimidazolyl)]methylamine as ionophore was investigated. The electrode exhibited a Nernstian response to perchlorate ions over the activity range of 1.5 x 10(-7) to 1.0 x 10(-1) M with a limit of detection of 5.2 x 10(-8) M between pH range of 2.0-10.0, giving a relatively fast response and reversibility within 5 s. The selectivity coefficient was calculated using fixed interference method (FIM). The electrode worked well for nearly 3 months. The electrode can also be used in partially non-aqueous media having up to 25% (v/v) methanol, ethanol or acetone contents with no significant change in the value of slope or working concentration range. It was successfully applied for the direct determination of perchlorate content in water and human urine samples with satisfactory results.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [31] Nickel ion-selective PVC membrane electrode based on a new t-octyl-calix[6]arene derivative
    Belhamel, K
    Ludwig, R
    Benamor, M
    MICROCHIMICA ACTA, 2005, 149 (1-2) : 145 - 150
  • [32] Lead-selective poly(vinyl cholride) membrane electrode based on piroxicam as a neutral carrier
    Sadeghi, S
    Dashti, GR
    Shamsipur, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3): : 223 - 228
  • [33] Iron-selective Poly(Vinyl Chloride) Membrane Electrode Based on Norfloxacin as a Neutral Carrier
    Saber, Amr L.
    Hameed, Ahmed M.
    Sayqal, Ali A.
    Alessa, Hussain
    Alharbi, Ahmed
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10076 - 10087
  • [34] New membrane for copper-selective electrode incorporating a new thiophosphoril-containing macrocycle as neutral carrier
    de Oliveira, IAM
    Pla-Roca, M
    Escriche, L
    Casabó, J
    Zine, N
    Bausells, J
    Samitier, J
    Errachid, A
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (2-3): : 394 - 398
  • [35] Al(III)-Selective electrode based on furil as neutral carrier
    Mousavi, MF
    Arvand-Barmchi, M
    Zanjanchi, MA
    ELECTROANALYSIS, 2001, 13 (13) : 1125 - 1128
  • [36] LITHIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    GUGGI, M
    FIEDLER, U
    PRETSCH, E
    SIMON, W
    ANALYTICAL LETTERS, 1975, 8 (12) : 857 - 866
  • [37] CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    AMMANN, D
    PRETSCH, E
    SIMON, W
    ANALYTICAL LETTERS, 1972, 5 (11) : 843 - 850
  • [38] Neutral Carrier-Based Zinc-Selective Electrode
    Kumar, Pawan
    Mittal, Susheel K.
    Kumar, S. K. Ashok
    SENSOR LETTERS, 2012, 10 (3-4) : 979 - 984
  • [39] SODIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    AMMANN, D
    PRETSCH, E
    SIMON, W
    ANALYTICAL LETTERS, 1974, 7 (01) : 23 - 32
  • [40] NEUTRAL-CARRIER-BASED MAGNESIUM-SELECTIVE ELECTRODE
    ROUILLY, MV
    BADERTSCHER, M
    PRETSCH, E
    SUTER, G
    SIMON, W
    ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2013 - 2016