7T MRSafety

被引:40
|
作者
Fagan, Andrew J. [1 ]
Bitz, Andreas K. [2 ]
Bjorkman-Burtscher, Isabella M. [3 ]
Collins, Christopher M. [4 ]
Kimbrell, Vera [5 ]
Raaijmakers, Alexander J. E. [6 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Univ Appl Sci, FH Aachen, Fac Elect Engn & Informat Technol, Aachen, Germany
[3] Univ Gothenburg, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Dept Radiol, Gothenburg, Sweden
[4] NYU Langone Med Ctr, Ctr Adv Imaging Innovat & Res, New York, NY USA
[5] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[6] UMC Utrecht, Dept Radiol, Utrecht, Netherlands
关键词
7TeslaMRI; MRSsafety; SAR; radiofrequency coils; parallel transmission; numerical simulations; implants; HIGH-FIELD MRI; PARALLEL TRANSMISSION; HUMAN HEAD; MAGNETIC-FIELDS; SURFACE COILS; LOCAL SAR; TEMPERATURE; SIMULATIONS; IMPLANTS; EXCITATION;
D O I
10.1002/jmri.27319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2
引用
收藏
页码:333 / 346
页数:14
相关论文
共 50 条
  • [31] Anesthesia and monitoring for FMRI experiments at 7T in rats
    Elbel, GK
    Kalisch, R
    Schadrack, J
    Droese, DG
    Hipp, RF
    Auer, DP
    ANESTHESIA AND ANALGESIA, 2000, 90 (02):
  • [32] 7T MRI Loop Antenna for Carotid Imaging
    Hinge, Lars
    Mortensen, Nicolai
    Zhurbenko, Vitaliy
    Boer, Vincent O.
    Wang, Wenjun
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020, : 1007 - 1010
  • [33] A Dependable SRAM with 7T/14T Memory Cells
    Fujiwara, Hidehiro
    Okumura, Shunsuke
    Iguchi, Yusuke
    Noguchi, Hiroki
    Kawaguchi, Hiroshi
    Yoshimoto, Masahiko
    IEICE TRANSACTIONS ON ELECTRONICS, 2009, E92C (04): : 423 - 432
  • [34] Development of Chemical Exchange Saturation Transfer at 7T
    Dula, Adrienne N.
    Asche, Elizabeth M.
    Landman, Bennett A.
    Welch, E. Brian
    Pawate, Siddharama
    Sriram, Subramaniam
    Gore, John C.
    Smith, Seth A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) : 831 - 838
  • [35] Relaxation Times of Skeletal Muscle Metabolites at 7T
    Wang, Ligong
    Salibi, Nouha
    Wu, Yan
    Schweitzer, Mark E.
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) : 1457 - 1464
  • [36] Microaneurysm Diagnosed With 7T Magnetic Resonance Imaging
    Wang, Linlin
    Zhang, Yingkui
    Sui, Binbin
    Zhao, Xingquan
    Ji, Ruijun
    STROKE, 2022, 53 (06) : E224 - E225
  • [37] Grey Matter Segmentation of 7T MR Images
    Strumia, Maddalena
    Feltell, David
    Evangelou, Nikos
    Gowland, Penny
    Tench, Christopher
    Bai, Li
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3710 - 3714
  • [38] Detection of cerebral NAD+ in humans at 7T
    de Graaf, Robin A.
    De Feyter, Henk M.
    Brown, Peter B.
    Nixon, Terence W.
    Rothman, Douglas L.
    Behar, Kevin L.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 828 - 835
  • [39] 7T: Physics, Safety, and Potential Clinical Applications
    Kraff, Oliver
    Quick, Harald H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1573 - 1589
  • [40] Exploratory 7T MRS in Huntington's disease
    van den Bogaard, S. J. A.
    Dumas, E. M.
    Teeuwisse, W.
    van Buchem, M. A.
    van der Grond, J.
    Roos, R. A. C.