7T MRSafety

被引:40
|
作者
Fagan, Andrew J. [1 ]
Bitz, Andreas K. [2 ]
Bjorkman-Burtscher, Isabella M. [3 ]
Collins, Christopher M. [4 ]
Kimbrell, Vera [5 ]
Raaijmakers, Alexander J. E. [6 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Univ Appl Sci, FH Aachen, Fac Elect Engn & Informat Technol, Aachen, Germany
[3] Univ Gothenburg, Sahlgrenska Univ Hosp, Sahlgrenska Acad, Dept Radiol, Gothenburg, Sweden
[4] NYU Langone Med Ctr, Ctr Adv Imaging Innovat & Res, New York, NY USA
[5] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[6] UMC Utrecht, Dept Radiol, Utrecht, Netherlands
关键词
7TeslaMRI; MRSsafety; SAR; radiofrequency coils; parallel transmission; numerical simulations; implants; HIGH-FIELD MRI; PARALLEL TRANSMISSION; HUMAN HEAD; MAGNETIC-FIELDS; SURFACE COILS; LOCAL SAR; TEMPERATURE; SIMULATIONS; IMPLANTS; EXCITATION;
D O I
10.1002/jmri.27319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh-field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer-published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2
引用
收藏
页码:333 / 346
页数:14
相关论文
共 50 条
  • [21] Giant Intracranial Aneurysms at 7T MRI
    Matsushige, T.
    Chen, B.
    Ringelstein, A.
    Umutlu, L.
    Forsting, M.
    Quick, H. H.
    Sure, U.
    Wrede, K. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 636 - 641
  • [22] A DC QUADRUPOLE 7T TEST FACILITY
    DEREUVER, JL
    STEFFENS, HA
    VANDEKLUNDERT, LJM
    JOURNAL DE PHYSIQUE, 1984, 45 (NC-1): : 813 - 816
  • [23] 7T SPECTROSCOPIC IMAGING FOR NEOCORTICAL EPILEPSY
    Pan, Jullie W.
    Avdievich, N. I.
    Spencer, D. D.
    Hetherington, H. P.
    Spencer, S. S.
    EPILEPSIA, 2009, 50 : 443 - 443
  • [24] Diffusion Tensor Imaging and Fibertracking at 7T
    Sammet, S.
    Irfanoglu, O.
    Koch, R.
    Schmalbrock, P.
    Choi, S.
    Machiraju, R.
    Yuh, W.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [25] Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T
    Lohr, David
    Terekhov, Maxim
    Weng, Andreas Max
    Schroeder, Anja
    Walles, Heike
    Schreiber, Laura Maria
    PLOS ONE, 2019, 14 (03):
  • [26] A hybrid hierarchical strategy for registration of 7T TOF-MRI to 7T PC-MRI intracranial vessel data
    Spitz, Lena
    Gaidzik, Franziska
    Stucht, Daniel
    Mattern, Hendrik
    Preim, Bernhard
    Saalfeld, Sylvia
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (05) : 837 - 844
  • [27] A hybrid hierarchical strategy for registration of 7T TOF-MRI to 7T PC-MRI intracranial vessel data
    Lena Spitz
    Franziska Gaidzik
    Daniel Stucht
    Hendrik Mattern
    Bernhard Preim
    Sylvia Saalfeld
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 837 - 844
  • [28] 7T MRI Loop Antenna for Carotid Imaging
    Hinge, Lars
    Mortensen, Nicolai
    Zhurbenko, Vitaliy
    Boer, Vincent O.
    Wang, Wenjun
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [29] Sharpness in motion corrected quantitative imaging at 7T
    Bazin, Pierre-Louis
    Nijsse, Hannah E.
    van der Zwaag, Wietske
    Gallichan, Daniel
    Alkemade, Anneke
    Vos, Frans M.
    Forstmann, Birte U.
    Caan, Matthan W. A.
    NEUROIMAGE, 2020, 222
  • [30] Classification of mouth movements using 7T fMRI
    Bleichner, M. G.
    Jansma, J. M.
    Salari, E.
    Freudenburg, Z. V.
    Raemaekers, M.
    Ramsey, N. F.
    JOURNAL OF NEURAL ENGINEERING, 2015, 12 (06)