Performance simulation of high resolution and high sensitivity Prism-PET brain scanner

被引:0
|
作者
Petersen, Eric [1 ]
Neilson, Peter [2 ]
LaBella, Andy [1 ]
Howanskvi, Adrian [1 ]
Cao, Xinjie [1 ]
Wang, Zipai [1 ]
Woody, Craig [3 ]
Biegon, Anat [1 ]
Rahmim, Arman [4 ]
Zhao, Wei [1 ]
Goldan, Amir [1 ]
机构
[1] SUNY Stony Brook, Stony Brook, NY 11794 USA
[2] Tech X Corp, Boulder, CO USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
[4] Univ British Columbia, Vancouver, BC, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1502
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Characterization of a high resolution and high sensitivity pre-clinical PET scanner with 3D event reconstruction
    Rissi, M.
    Bolle, E.
    Volgyes, D.
    Bjaalie, J. G.
    Dorholt, O.
    Hines, K. E.
    Rohne, O.
    Skretting, A.
    Stapnes, S.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 135 - 138
  • [42] Performance Simulation of an Ultrahigh Resolution Brain PET Scanner Using 1.2-mm Pixel Detectors
    Gaudin, Emilie
    Toussaint, Maxime
    Thibaudeau, Christian
    Pallie, Maxime
    Fontaine, Rejean
    Lecomte, Roger
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (03) : 334 - 342
  • [43] Performance evaluation of the MOLECUBES β-CUBE-a high spatial resolution and high sensitivity small animal PET scanner utilizing monolithic LYSO scintillation detectors
    Krishnamoorthy, Srilalan
    Blankemeyer, Eric
    Mollet, Pieter
    Surti, Suleman
    Van Holen, Roel
    Karp, Joel S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [44] Simulation Studies of the SAVANT High Resolution Dedicated Brain PET Scanner Using Individually Coupled APD Detectors and DOI Encoding
    Gaudin, Emilie
    Toussaint, Maxime
    Thibaudeau, Christian
    Fontaine, Rejean
    Normandin, Marc
    Petibon, Yoann
    Ouyang, Jinsong
    El Fakhri, Georges
    Lecomte, Roger
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [45] Sub-100 ps Coincidence Time Resolution in Depth-Encoding Prism-PET Modules: A Monte Carlo Simulation Study
    LaBella, Andy
    Zhao, Wei
    Woody, Craig
    Goldan, Amir
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [46] First PET Investigation of the Human Brain at 2 μL Resolution with the Ultra-High-Resolution (UHR) scanner
    Doyon, Vincent
    Sarrhini, Otman
    Loignon-Houle, Francis
    Auger, Etienne
    Toussaint, Maxime
    Thibaudeau, Christian
    Croteau, Etienne
    Beaudoin, Jean-Francois
    Lavallee, Eric
    Leroux, Jean-Daniel
    Lecomte, Roger
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [47] LOW DOSE FDG BRAIN IMAGING ON A HIGH SENSITIVITY TIME-OF-FLIGHT PET SCANNER
    Bailey, D.
    Bailey, E.
    Willowson, K.
    [J]. INTERNAL MEDICINE JOURNAL, 2012, 42 : 5 - 5
  • [48] H2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study
    Lai, Youfang
    Wang, Qian
    Zhou, Shiwei
    Xie, Zhaoheng
    Qi, Jinyi
    Cherry, Simon R.
    Jin, Mingwu
    Chi, Yujie
    Du, Junwei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [49] Submillimeter-Resolution PET for High-Sensitivity Mouse Brain Imaging
    Kang, Han Gyu
    Tashima, Hideaki
    Wakizaka, Hidekatsu
    Nishikido, Fumihiko
    Higuchi, Makoto
    Takahashi, Miwako
    Yamaya, Taiga
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2023, 64 (06) : 978 - 985
  • [50] MicroPET: A high resolution PET scanner for imaging small animals
    Cherry, SR
    Shao, Y
    Siegel, S
    Silverman, RW
    Meadors, K
    Young, J
    Jones, WF
    Newport, D
    Moyers, C
    Mumcuoglu, EU
    Chatziioannou, A
    Farquhar, T
    Andreaco, M
    Paulus, M
    Binkley, D
    Nutt, R
    Phelps, ME
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1120 - 1124