Calibration of the GENEA accelerometer for assessment of physical activity intensity in children

被引:211
|
作者
Phillips, Lisa R. S. [1 ]
Parfitt, Gaynor [2 ]
Rowlands, Alex V. [2 ]
机构
[1] Univ Exeter, Exeter EX4 4QJ, Devon, England
[2] Univ S Australia, Sch Hlth Sci, Adelaide, SA 5001, Australia
关键词
Activity intensity; Cut-points; Wrist worn; ActiGraph; Physical activity; VALIDATION;
D O I
10.1016/j.jsams.2012.05.013
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: The purpose of the study was to establish activity intensity cut-points for the GENEA accelerometer via calibration with oxygen consumption ((V) over dot O-2). Design: The study was a lab-based validation and calibration study. Methods: Forty-four children, aged 8-14 years, completed eight activities (ranging from lying supine to a medium paced run) whilst wearing GENEA accelerometers at three locations (each wrist and at the right hip), an ActiGraph GT1M at the hip and a portable gas analyser. ActiGraph output and (V) over dot O-2 were used for assessmeht of concurrent and criterion validity, respectively. Pearson's r correlations were used to assess validity of the GENEA monitors at each location and location-specific activity intensity cut-points were established via Receiver Operator Characteristic curve analysis. Results: The GENEA showed good criterion validity at both wrist locations (right: r=.900; left: r=.910, both p<0.01), although the hip-mounted monitor demonstrated significantly higher criterion validity (r=.965, p<0.05). Similar results were shown for concurrent validity (right: r=.830; left: r=.845; hip: r=.985, all p<0.01). GENEAs, irrespective of wear location, accurately discriminated between all activity intensities (sedentary, light, moderate and vigorous) with the hip mounted monitor recording the largest area under the curve for each intensity (area under the curve = 0.94-0.99). Conclusions: The GENEA can be used to accurately assess children's physical activity intensity when worn at either the wrist or the hip. (C) 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [21] An inclinometer and accelerometer system for measuring physical activity in children
    Lanningham-Foster, L
    Jensen, T
    McCrady, S
    Levine, J
    [J]. OBESITY RESEARCH, 2004, 12 : A116 - A116
  • [22] Relationships between accelerometer-assessed physical activity and health in children: impact of the activity-intensity classification method
    Stone, Michelle R.
    Rowlands, Ann V.
    Eston, Roger G.
    [J]. JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2009, 8 (01) : 136 - 143
  • [23] Individualized Relative-Intensity Physical Activity Accelerometer Cut Points
    Siddique, Juned
    Aaby, David
    Montag, Samantha E.
    Sidney, Stephen
    Sternfeld, Barbara
    Welch, Whitney A.
    Carnethon, Mercedes R.
    Liu, Kiang
    Craft, Lynette L.
    Gabriel, Kelley Pettee
    Gibbs, Bethany Barone
    Reis, Jared P.
    Freedson, Patty
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2020, 52 (02): : 398 - 407
  • [24] Influence of Accelerometer Calibration on the Estimation of Objectively Measured Physical Activity: The Tromsø Study
    Weitz, Marc
    Morseth, Bente
    Hopstock, Laila A.
    Horsch, Alexander
    [J]. JOURNAL FOR THE MEASUREMENT OF PHYSICAL BEHAVIOUR, 2024, 7 (01)
  • [25] Classification Accuracy of the Wrist-Worn GENEA Accelerometer During Structured Activity Bouts
    Welch, Whitney A.
    Bassett, David R.
    Thompson, Dixie L.
    Freedson, Patty S.
    Staudenmayer, John W.
    John, Dinesh
    Steeves, Jeremy A.
    Conger, Scott A.
    Ceaser, Tyrone
    Howe, Cheryl A.
    Sasaki, Jeffer E.
    Fitzhugh, Eugene C.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 620 - 620
  • [26] Validation and calibration of physical activity monitors in children
    Puyau, MR
    Adolph, AL
    Vohra, FA
    Butte, NF
    [J]. OBESITY RESEARCH, 2002, 10 (03): : 150 - 157
  • [27] Integration of physiological and accelerometer data to improve physical activity assessment
    Strath, SJ
    Brage, S
    Ekelund, U
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11): : S563 - S571
  • [28] Accelerometer Assessment of Physical Activity in Active, Healthy Older Adults
    Copeland, Jennifer L.
    Esliger, Dale W.
    [J]. JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2009, 17 (01) : 17 - 30
  • [29] Validation of triaxial accelerometer and physical activity monitoring in children.
    Liu, WY
    Lee, M
    Rodriguez, S
    Chang, RK
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S118 - S118
  • [30] Comparison of pedometer and accelerometer measures of physical activity in preschool children
    Cardon, Greet
    De Bourdeaudhuij, Ilse
    [J]. PEDIATRIC EXERCISE SCIENCE, 2007, 19 (02) : 205 - 214