Portable Light Pen 3D Vision Coordinate Measuring System-Probe Tip Center Calibration

被引:14
|
作者
Liu, Shugui [1 ]
Zhang, Hongling [1 ]
Dong, Yinghua [1 ]
Tang, Shaliang [1 ]
Jiang, Zhenzhu [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
来源
MEASUREMENT SCIENCE REVIEW | 2013年 / 13卷 / 04期
关键词
Probe tip; center calibration; light pen; portable 3D vision coordinate measuring system; reference conical hole; LASER; METROLOGY; POSITION;
D O I
10.2478/msr-2013-0030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For different tasks, probe tip should be changed in the 3D vision coordinate measuring system and the accurate determination of probe tip center position is critical. A novel and simple approach for calibrating the probe tip center position of the light pen is presented in this paper. Hundreds of images of the light pen with different postures are collected while the probe tip is kept in firm contact with a reference conical hole. The probe tip position is determined by computing the rotation matrix and translation vector from the obtained images by using the least square fitting method. The experimental results demonstrate the effectiveness of the proposed approach. Its repeatability reaches 0.033 mm, 0.030 mm, and 0.043 mm in x, y, and z axes, respectively, and its convergence speed is satisfactory.
引用
收藏
页码:194 / 199
页数:6
相关论文
共 50 条
  • [21] A Novel Global Calibration Approach for Multi-Viewpoint 3D Vision Measuring System
    Sun, Pengfei
    Tan, Haishu
    Zhou, Fuqiang
    IEEE ACCESS, 2023, 11 : 71692 - 71704
  • [22] A CAD CAM SYSTEM FOR 3D COORDINATE MEASURING DATA
    LEE, AC
    CHEN, DP
    LIN, CL
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 1990, 28 (12) : 2353 - 2371
  • [23] Development of portable 3D optical measuring system using structured light projection method
    Aoki, Hiroshi
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS III, 2014, 9110
  • [24] 3-step-calibration of 3D vision measurement system based-on structured light
    Tang, Rui-Yin
    Zeng, Zhou-Mo
    Sun, Chang-Ku
    Wang, Peng
    International Journal of Automation Technology, 2014, 8 (03) : 484 - 489
  • [25] On Structured Light Vision Sensor Calibration in a Robot Based 3D Laser Scanning System
    Fan, Tiecheng
    Wu, Defeng
    Ma, Zi
    Li, Aiguo
    2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2009), VOLS 1-4, 2009, : 1312 - 1316
  • [26] Calibration and image enhancement algorithm of portable structured light 3D gauge system for improving accuracy
    Tao, Li
    Harding, Kevin
    Jia, Ming
    Song, Guiju
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS, 2010, 7855
  • [27] A Calibration Method for Vision Sensor System with 3D Target
    Yang, Xuemei
    Li, Yuan
    Zhao, Kaixin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 6754 - 6759
  • [28] A novel calibration approach to structured light 3D vision inspection
    Zhang, GJ
    Wei, ZZ
    OPTICS AND LASER TECHNOLOGY, 2002, 34 (05): : 373 - 380
  • [29] A calibration system for measuring 3D ground truth for validation and error analysis of robot vision algorithms
    Stolkin, R.
    Greig, A.
    Gilby, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (10) : 2721 - 2730
  • [30] Calibration of a 3D vision system using pattern projection
    Lu, RS
    Li, YF