Screening of abnormal LiF:Mg,Cu,P glow curves

被引:1
|
作者
Bautro, N
Cassata, J
Rotunda, JE
机构
[1] John R Marsh Canc Ctr, Hagerstown, MD 21742 USA
[2] USN, Dosimetry Ctr, Bethesda, MD 20889 USA
[3] St Gobain Ind Ceram Inc, Biocron NE Div, Solon, OH 44139 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a032762
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A process to screen electronically abnormal LiF:Mg,Cu,P glow curves in routine dosimetry is proposed. The method is based on the fact that when a glow curve is normalised to a part of the integral of the glow curve it loses its dependence on the magnitude of the exposure. This characteristic allows a glow curve from a dosemeter exposed in the field to be compared with an 'ideal' glow curve from the same dosemeter. A difference curve is generated from the differences between the normalised 'ideal' and the normalised field curves. This difference curve can be used to identify the abnormal characteristics of the field-generated glow curve and, since both normalised curves are essentially the same, the anomalies can be resolved by reconstructing the field curve to match the 'ideal' curve.
引用
收藏
页码:387 / 391
页数:5
相关论文
共 50 条
  • [1] The application of computerised analysis of glow curves to personal dosimetry in LiF:Mg,Cu,P
    Tang, KY
    Zhu, HY
    Liu, BX
    Shen, WX
    Wang, YC
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 239 - 242
  • [2] The application of computerised analysis of glow curves to personal dosimetry in LiF:Mg,Cu,P
    Tang, KY
    Zhu, HY
    Liu, BX
    Shen, WX
    Wang, YC
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A239 - A242
  • [3] Heating rate effect on thermoluminescence glow curves of LiF:Mg,Cu,P+PTFE phosphor
    Cruz-Zaragoza, E.
    Gonzalez, P. R.
    Azorin, J.
    Furetta, C.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (10) : 1369 - 1373
  • [4] Comparative studies of glow peaks and kinetic trapping parameters of LiF(Mg,Cu), LiF(Mg,Cu,P), LiF(Mg,Cu,Si) and LiF(Mg,Cu,Na,Si) single crystals
    Laopaiboon, R.
    Bootjomchai, C.
    Pencharee, S.
    Laopaiboon, J.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (02): : 129 - 136
  • [5] Fast automatic glow curve deconvolution of LiF:Mg,Cu,P curves and its application in routine dosimetry
    Ros, JMG
    Vergara, JCS
    Romero, AM
    Budzanowski, M
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 249 - 252
  • [7] Role of dopants in LiF:Mg,Cu, LiF:Mg,P and LiF:Mg,Cu,P detectors
    Mohammadi, Kh
    Zarandi, A. Moussavi
    Afarideh, H.
    Shahmaleki, S.
    JOURNAL OF SOLID STATE CHEMISTRY, 2013, 202 : 282 - 290
  • [8] Glow curve analysis of long-term stability of LiF:Mg,Cu,P as compared to LiF:Mg,Ti
    Duggan, L
    Kron, T
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 213 - 216
  • [9] LiF:Mg,Cu,P glow curve shape dependence on heating rate
    Luo, L. Z.
    Velbeck, K. J.
    Moscovitch, M.
    Rotunda, J. E.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 184 - 190
  • [10] A new approach to screening abnormal glow curves
    Tawil, RA
    Rotunda, JE
    Velbeck, KJ
    Tan, Y
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D322 - D324