In vitro compatibility of various cardioactive drugs during simulated Y-site administration

被引:6
|
作者
Humbert-Delaloye, Valia [1 ,2 ,3 ]
Berger-Gryllaki, Markoulina [1 ]
Voirol, Pierre [1 ]
Gattlen, Laurent [4 ]
Pannatier, Andre [1 ,2 ,3 ]
机构
[1] Univ Hosp Ctr CHUV, Dept Pharm, Lausanne, Vaud, Switzerland
[2] Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[3] Univ Lausanne, Geneva, Switzerland
[4] Univ Hosp Ctr CHUV, Adult Intens Care Unit, Lausanne, Vaud, Switzerland
关键词
VISUAL COMPATIBILITY; SODIUM-NITROPRUSSIDE; AMIODARONE; INJECTION; SYSTEMS; SETS;
D O I
10.1136/ejhpharm-2012-000239
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives Physicochemical incompatibilities between intravenous drugs are a recurrent problem in ICUs. A study was undertaken to evaluate the physicochemical compatibility of five common associations of cardioactive drugs: dopamine (DA)-norepinephrine (NE); dobutamine (DU)-NE; amiodarone (AM)-DU-NE; DU-sodium nitroprusside (NI)+/- sodium thiosulfate (THIO); and NI-THIO. Methods The drugs were diluted in the usual manner performed in the ICU. Their compatibility was verified by visual inspection of the different mixtures in glass tubes and by chemical assays and pH determination of the mixtures collected during in vitro simulated Y-site administration (solutions prepared in syringes placed on syringe pumps and connected to a Swan-Ganz catheter). Solutions were considered to be compatible in the absence of any visual change in the solution and of any significant variation in pH value and drug concentration at each time of the study. Results DA-NE, DU-NE, DU-NI (+/- THIO) and NI-THIO associations were compatible over 24 h in the tested proportion ranges, with the proviso that NI was protected from light. In addition, it was observed that AM, DU and NE were compatible but, in the dynamic simulation, AM reached the expected concentration only after 4 h. Conclusions When combined, the cardioactive amines were stable over 24 h. AM was compatible with DU and NE, but with a latency period owing to its adsorption on the heparin-coated Swan-Ganz catheter. Mixtures involving NI were compatible provided that NI was supplied in amber syringes or protected with aluminum foil.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [31] Physical compatibility of Xuebijing injection with 53 intravenous drugs during simulated Y-site administration
    Tong, Tong
    Li, Peifang
    Ding, Haiwen
    Huang, Ying
    Liu, Sheng
    PLOS ONE, 2024, 19 (03):
  • [32] VISUAL COMPATIBILITY OF FLUCONAZOLE WITH COMMONLY USED INJECTABLE DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    LOR, E
    SHEYBANI, T
    TAKAGI, J
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1991, 48 (04): : 744 - 746
  • [33] VISUAL COMPATIBILITY OF ESMOLOL HYDROCHLORIDE AND VARIOUS INJECTABLE DRUGS DURING SIMULATED Y-SITE INJECTION
    COLUCCI, RD
    COBUZZI, LE
    HALPERN, NA
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1988, 45 (03): : 630 - 632
  • [34] Assessment of the Physical Compatibility of Eravacycline and Common Parenteral Drugs During Simulated Y-site Administration
    Avery, Lindsay M.
    Chen, Iris H.
    Reyes, Sergio
    Nicolau, David P.
    Kuti, Joseph L.
    CLINICAL THERAPEUTICS, 2019, 41 (10) : 2162 - 2170
  • [35] Physical compatibility of colistin with analgesics during simulated Y-site administration
    Dettlaff, Katarzyna
    Kowalska, Aleksandra
    Gostynska, Aleksandra
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2024, 81 (13) : e365 - e371
  • [36] VISUAL COMPATIBILITY OF DILTIAZEM WITH COMMONLY USED INJECTABLE DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    ZANETTI, LAF
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1992, 49 (08): : 1911 - 1911
  • [37] Compatibility of levofloxacin with 34 medications during simulated Y-site administration
    Saltsman, CL
    Tom, CM
    Mitchell, A
    Fan, JH
    Gailey, RA
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1999, 56 (14) : 1458 - 1459
  • [38] Visual compatibility of oritavancin diphosphate with selected coadministered drugs during simulated Y-site administration
    Kumar, Atul
    Mann, Henry J.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2010, 67 (19) : 1640 - 1644
  • [39] STABILITY AND COMPATIBILITY OF FLUOROURACIL AND MANNITOL DURING SIMULATED Y-SITE ADMINISTRATION
    WOLOSCHUK, DMM
    WERMELING, JR
    PRUEMER, JM
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1991, 48 (10): : 2158 - 2160
  • [40] Compatibility of palonosetron with cyclophosphamide and with ifosfamide during simulated Y-site administration
    Xu, QA
    Trissel, LA
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (19) : 1998 - 2000