In vitro compatibility of various cardioactive drugs during simulated Y-site administration

被引:6
|
作者
Humbert-Delaloye, Valia [1 ,2 ,3 ]
Berger-Gryllaki, Markoulina [1 ]
Voirol, Pierre [1 ]
Gattlen, Laurent [4 ]
Pannatier, Andre [1 ,2 ,3 ]
机构
[1] Univ Hosp Ctr CHUV, Dept Pharm, Lausanne, Vaud, Switzerland
[2] Univ Geneva, Sch Pharmaceut Sci, Geneva, Switzerland
[3] Univ Lausanne, Geneva, Switzerland
[4] Univ Hosp Ctr CHUV, Adult Intens Care Unit, Lausanne, Vaud, Switzerland
关键词
VISUAL COMPATIBILITY; SODIUM-NITROPRUSSIDE; AMIODARONE; INJECTION; SYSTEMS; SETS;
D O I
10.1136/ejhpharm-2012-000239
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives Physicochemical incompatibilities between intravenous drugs are a recurrent problem in ICUs. A study was undertaken to evaluate the physicochemical compatibility of five common associations of cardioactive drugs: dopamine (DA)-norepinephrine (NE); dobutamine (DU)-NE; amiodarone (AM)-DU-NE; DU-sodium nitroprusside (NI)+/- sodium thiosulfate (THIO); and NI-THIO. Methods The drugs were diluted in the usual manner performed in the ICU. Their compatibility was verified by visual inspection of the different mixtures in glass tubes and by chemical assays and pH determination of the mixtures collected during in vitro simulated Y-site administration (solutions prepared in syringes placed on syringe pumps and connected to a Swan-Ganz catheter). Solutions were considered to be compatible in the absence of any visual change in the solution and of any significant variation in pH value and drug concentration at each time of the study. Results DA-NE, DU-NE, DU-NI (+/- THIO) and NI-THIO associations were compatible over 24 h in the tested proportion ranges, with the proviso that NI was protected from light. In addition, it was observed that AM, DU and NE were compatible but, in the dynamic simulation, AM reached the expected concentration only after 4 h. Conclusions When combined, the cardioactive amines were stable over 24 h. AM was compatible with DU and NE, but with a latency period owing to its adsorption on the heparin-coated Swan-Ganz catheter. Mixtures involving NI were compatible provided that NI was supplied in amber syringes or protected with aluminum foil.
引用
收藏
页码:110 / 116
页数:7
相关论文
共 50 条
  • [21] VISUAL COMPATIBILITY OF FOSCARNET WITH OTHER INJECTABLE DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    BALTZ, JK
    KENNEDY, P
    MINOR, JR
    GALLELLI, J
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1990, 47 (09): : 2075 - 2077
  • [22] Stability and compatibility of tirofiban hydrochloride during simulated Y-site administration with other drugs
    Bergquist, PA
    Manas, D
    Hunke, WA
    Reed, RA
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2001, 58 (13) : 1218 - 1223
  • [23] VISUAL COMPATIBILITY OF ZIDOVUDINE WITH OTHER INJECTABLE DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    BASHAW, ED
    AMANTEA, MA
    MINOR, JR
    GALLELLI, JF
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1988, 45 (12): : 2532 - 2533
  • [24] COMPATIBILITY OF MIDAZOLAM HYDROCHLORIDE AND LORAZEPAM WITH SELECTED DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    SWART, EL
    MOOREN, RAG
    VANLOENEN, AC
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1995, 52 (18) : 2020 - 2022
  • [25] Compatibility of ceftaroline fosamil for injection with selected drugs during simulated Y-site administration
    Singh, Brahma N.
    Dedhiya, Mahendra G.
    DiNunzio, James
    Chan, Pak
    Kupiec, Thomas C.
    Trissel, Lawrence A.
    Laudano, Joseph B.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2011, 68 (22) : 2163 - 2169
  • [26] PHYSICAL COMPATIBILITY OF IBUPROFEN AND SELECTED PARENTERAL DRUGS DURING SIMULATED Y-SITE ADMINISTRATION
    Dettlaff, Katarzyna
    Dominiak, Katarzyna
    Klimaszewska, Marta
    Gostynska, Aleksandra
    ACTA POLONIAE PHARMACEUTICA, 2023, 80 (02): : 255 - 267
  • [27] Physical compatibility of pemetrexed disodium with other drugs during simulated Y-site administration
    Trissel, LA
    Saenz, CA
    Ogundele, AB
    Ingram, DS
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2004, 61 (21) : 2289 - 2293
  • [28] Compatibility of propofol injectable emulsion with selected drugs during simulated Y-site administration
    Trissel, LA
    Gilbert, DL
    Martinez, JF
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1997, 54 (11) : 1287 - 1292
  • [29] Physical Compatibility of Meropenem and Vaborbactam With Select Intravenous Drugs During Simulated Y-site Administration
    Kidd, James M.
    Avery, Lindsay M.
    Asempa, Tomefa E.
    Nicolau, David P.
    Kuti, Joseph L.
    CLINICAL THERAPEUTICS, 2018, 40 (02) : 261 - 269
  • [30] Physical compatibility of sulbactam/durlobactam with select intravenous drugs during simulated Y-site administration
    Ruiz, Victor H.
    Shen, Yuwei
    Abouelhassan, Yasmeen
    Fouad, Aliaa
    Nicolau, David P.
    Kuti, Joseph L.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2024, 81 (01) : E21 - E29