Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion

被引:47
|
作者
Greene, Nathaniel T. [1 ,2 ]
Mattingly, Jameson K. [1 ]
Hartl, Renee M. Banakis [1 ]
Tollin, Daniel J. [1 ,2 ]
Cass, Stephen P. [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Otolaryngol, Aurora, CO USA
[2] Univ Colorado, Sch Med, Dept Physiol & Biophys, Aurora, CO 80045 USA
关键词
Cochlear implant; Electroacoustic stimulation; Hearing preservation; Intracochlear pressures; MIDDLE-EAR IMPLANT; HEARING PRESERVATION; CONDUCTION; NOISE; STIMULATION; EXPOSURE; SURGEON; DESIGN; SYSTEM; AIR;
D O I
10.1097/MAO.0000000000001232
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high-intensity sound transients. Background: Many patients receiving a CI have some remaining functional hearing at low frequencies; thus, devices and surgical techniques have been developed to use this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low-frequency hearing is lost after CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Methods: Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli and tympani were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows, whereas CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Results: Pressures in the scala tympani tended to be larger in magnitude than pressures in the scala vestibuli, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170 dB sound pressure level. Instances of pressure transients varied with electrode styles. Conclusion: Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high-level sounds and thus could cause damage to the basilar membrane and/or hair cells.
引用
收藏
页码:1541 / 1548
页数:8
相关论文
共 50 条
  • [41] A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique
    Roland, JT
    LARYNGOSCOPE, 2005, 115 (08): : 1325 - 1339
  • [42] Model and Parameter Identification of Friction during Robotic Insertion of Cochlear-Implant Electrode Arrays
    Zhang, Jian
    Bhattacharyya, Samrat
    Simaan, Nabil
    ICRA: 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-7, 2009, : 3528 - 3533
  • [43] Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography
    Gijs K. A. van Wermeskerken
    Mathias Prokop
    Adriaan F. van Olphen
    Frans W. J. Albers
    European Archives of Oto-Rhino-Laryngology, 2007, 264 : 1405 - 1407
  • [44] Change in Endocochlear Potential During Experimental Insertion of a Simulated Cochlear Implant Electrode in the Guinea Pig
    Oshima, Hidetoshi
    Ikeda, Ryoukichi
    Nomura, Kazuhiro
    Yamazaki, Muneharu
    Hidaka, Hiroshi
    Katori, Yukio
    Oshima, Takeshi
    Kawase, Tetsuaki
    Kobayashi, Toshimitsu
    OTOLOGY & NEUROTOLOGY, 2014, 35 (02) : 234 - 240
  • [45] In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays
    Ketten, DR
    Vannier, MW
    Skinner, MW
    Gates, GA
    Wang, G
    Neely, JG
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1998, 107 (11): : 1 - 16
  • [46] The evaluation of a slim perimodiolar electrode: surgical technique in relation to intracochlear position and cochlear implant outcomes
    Floris Heutink
    Berit M. Verbist
    Lucas H. M. Mens
    Wendy J. Huinck
    Emmanuel A. M. Mylanus
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 343 - 350
  • [47] The evaluation of a slim perimodiolar electrode: surgical technique in relation to intracochlear position and cochlear implant outcomes
    Heutink, Floris
    Verbist, Berit M.
    Mens, Lucas H. M.
    Huinck, Wendy J.
    Mylanus, Emmanuel A. M.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (02) : 343 - 350
  • [48] Functionalized Cochlear Implant Electrode for Intracochlear Histamine Detection via Molecularly Imprinted Polymer Coating
    Putzeys, Tristan
    Wackers, Gideon
    Jamieson, Oliver
    Peeters, Marloes
    Doll, Theodor
    Wagner, Patrick
    Wuebbenhorst, Michael
    Verhaert, Nicolas
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2024, 221 (19):
  • [49] Evaluation of Real-Time Intracochlear Electrocochleography for Guiding Cochlear Implant Electrode Array Position
    Scheperle, Rachel
    Etler, Christine
    Oleson, Jacob
    Dunn, Camille
    Kashani, Rustin
    Claussen, Alexander
    Gantz, Bruce J.
    Hansen, Marlan R.
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
  • [50] Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography
    van Wermeskerken, Gijs K. A.
    Prokop, Mathias
    van Olphen, Adriaan F.
    Albers, Frans W. J.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2007, 264 (12) : 1405 - 1407