Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion

被引:47
|
作者
Greene, Nathaniel T. [1 ,2 ]
Mattingly, Jameson K. [1 ]
Hartl, Renee M. Banakis [1 ]
Tollin, Daniel J. [1 ,2 ]
Cass, Stephen P. [1 ]
机构
[1] Univ Colorado, Sch Med, Dept Otolaryngol, Aurora, CO USA
[2] Univ Colorado, Sch Med, Dept Physiol & Biophys, Aurora, CO 80045 USA
关键词
Cochlear implant; Electroacoustic stimulation; Hearing preservation; Intracochlear pressures; MIDDLE-EAR IMPLANT; HEARING PRESERVATION; CONDUCTION; NOISE; STIMULATION; EXPOSURE; SURGEON; DESIGN; SYSTEM; AIR;
D O I
10.1097/MAO.0000000000001232
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: Cochlear implant (CI) electrode insertion into the round window induces pressure transients in the cochlear fluid comparable to high-intensity sound transients. Background: Many patients receiving a CI have some remaining functional hearing at low frequencies; thus, devices and surgical techniques have been developed to use this residual hearing. To maintain functional acoustic hearing, it is important to retain function of any hair cells and auditory nerve fibers innervating the basilar membrane; however, in a subset of patients, residual low-frequency hearing is lost after CI insertion. Here, we test the hypothesis that transient intracochlear pressure spikes are generated during CI electrode insertion, which could cause damage and compromise residual hearing. Methods: Human cadaveric temporal bones were prepared with an extended facial recess. Pressures in the scala vestibuli and tympani were measured with fiber-optic pressure sensors inserted into the cochlea near the oval and round windows, whereas CI electrodes (five styles from two manufacturers) were inserted into the cochlea via a round window approach. Results: Pressures in the scala tympani tended to be larger in magnitude than pressures in the scala vestibuli, consistent with electrode insertion into the scala tympani. CI electrode insertion produced a range of pressure transients in the cochlea that could occur alone or as part of a train of spikes with equivalent peak sound pressure levels in excess of 170 dB sound pressure level. Instances of pressure transients varied with electrode styles. Conclusion: Results suggest electrode design, insertion mechanism, and surgical technique affect the magnitude and rate of intracochlear pressure transients during CI electrode insertion. Pressure transients showed intensities similar to those elicited by high-level sounds and thus could cause damage to the basilar membrane and/or hair cells.
引用
收藏
页码:1541 / 1548
页数:8
相关论文
共 50 条
  • [21] Simulation for Training Cochlear Implant Electrode Insertion
    Ma, Xingjun
    Wijewickrema, Sudanthi
    Zhou, Yun
    Copson, Bridget
    Bailey, James
    Kennedy, Gregor
    O'Leary, Stephen
    2017 IEEE 30TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2017, : 1 - 6
  • [22] Detection of Translocation of Cochlear Implant Electrode Arrays by Intracochlear Impedance Measurements
    Dong, Yu
    Briaire, Jeroen J.
    Siebrecht, Michael
    Stronks, H. Christiaan
    Frijns, Johan H. M.
    EAR AND HEARING, 2021, 42 (05): : 1397 - 1404
  • [23] Intracochlear position of cochlear implant electrodes
    Gstoettner, W
    Hamzavi, J
    Franz, P
    Plenk, H
    Czerny, C
    Susani, M
    Adunka, O
    Baumgartner, WD
    WIENER KLINISCHE WOCHENSCHRIFT, 2000, 112 (11) : 477 - 480
  • [24] Can fresh frozen heads be used to perform hydraulic pressure measurements during cochlear implant electrode insertion?
    Snels, Chantal
    Van Driessche, Veroniek
    Kerckaert, Ingrid
    Dhooge, Ingeborg
    B-ENT, 2021, 17 (02): : 75 - 80
  • [25] Intracochlear Electrocochleography: Influence of Scalar Position of the Cochlear Implant Electrode on Postinsertion Results
    Riggs, William J.
    Dwyer, Robert T.
    Holder, Jourdan T.
    Mattingly, Jameson K.
    Ortmann, Amanda
    Noble, Jack H.
    Dawant, Benoit M.
    Valenzuela, Carla V.
    O'Connell, Brendan P.
    Harris, Michael S.
    Litvak, Leonid M.
    Koka, Kanthaiah
    Buchman, Craig A.
    Labadie, Robert F.
    Adunka, Oliver F.
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : E503 - E510
  • [26] Postinsertional Cable Movements of Cochlear Implant Electrodes and Their Effects on Intracochlear Pressure
    Todt, I.
    Karimi, D.
    Luger, J.
    Ernst, A.
    Mittmann, P.
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [27] Intracochlear position of cochlear implant electrodes
    Gstoettner, W
    Franz, P
    Hamzavi, J
    Plenk, H
    Baumgartner, W
    Czerny, C
    ACTA OTO-LARYNGOLOGICA, 1999, 119 (02) : 229 - 233
  • [28] Implications of Deep Electrode Insertion on Cochlear Implant Fitting
    Mathieu Gani
    Gregory Valentini
    Alain Sigrist
    Maria-Izabel Kós
    Colette Boëx
    Journal of the Association for Research in Otolaryngology, 2007, 8 : 69 - 83
  • [29] Cochlear implant electrode insertion: The round window revisited
    Roland, Peter S.
    Wright, Charles G.
    Isaacson, Brandon
    LARYNGOSCOPE, 2007, 117 (08): : 1397 - 1402
  • [30] Implications of deep electrode insertion on cochlear implant fitting
    Gani, Mathieu
    Valentini, Gregory
    Sigrist, Alain
    Kos, Maria-Izabel
    Boex, Colette
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (01): : 69 - 83