Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in low-energy test house under simulated occupancy conditions

被引:18
|
作者
Ally, Moonis R. [1 ]
Munk, Jeffrey D. [1 ]
Baxter, Van D. [1 ]
Gehl, Anthony C. [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
Exergy analysis; Energy analysis; Heat pump; Thermodynamics; R410A; Renewable energy; Ground source; EXCHANGERS;
D O I
10.1016/j.ijrefrig.2012.01.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents data, analyses, measures of performance, and conclusions for a ground-source heat pump (GSHP) providing space conditioning to a 345 m(2) house whose envelope is made of structural insulated panels. The entire house thermal load with R-SI-3.7 (R-US-21) walls, triple-pane windows (U-factor of 1.64 W m(-2) K (0.29 Btu h(-1) ft(-2) degrees F-1)) and solar heat gain coefficient of 0.25, a roof assembly with overall thermal resistance of about R-SI-8.8 (R-US-50), and low leakage rates of 0.74 ACH at 50 Pa, was satisfied with a 2.16 ton (7.56 kW) GSHP unit. Coefficient of performance is calculated on the basis of the total power input (including duct, ground loop, and control power losses). Exergy analysis provides a true measure of how closely actual performance approaches the ideal, and it unequivocally identifies, better than energy analysis does, the sources and causes of lost work - the root cause of system inefficiencies and wasted energy. Published by Elsevier Ltd.
引用
收藏
页码:1092 / 1103
页数:12
相关论文
共 39 条
  • [1] Exergy and energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions
    Ally, Moonis R.
    Munk, Jeffrey D.
    Baxter, Van D.
    Gehl, Anthony C.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2013, 36 (05) : 1417 - 1430
  • [2] Data, exergy, and energy analyses of a vertical-bore, ground-source heat pump for domestic water heating under simulated occupancy conditions
    Ally, Moonis R.
    Munk, Jeffrey D.
    Baxter, Van D.
    Gehl, Anthony C.
    [J]. APPLIED THERMAL ENGINEERING, 2015, 89 : 192 - 203
  • [3] Exergy analysis of a hybrid ground-source heat pump system
    Menberg, Kathrin
    Heo, Yeonsook
    Choi, Wonjun
    Ooka, Ryozo
    Choudhary, Ruchi
    Shukuya, Masanori
    [J]. APPLIED ENERGY, 2017, 204 : 31 - 46
  • [4] Operation performance test and energy efficiency analysis of ground-source heat pump systems
    Gao, Bo
    Zhu, Xiaoyue
    Yang, Xiaojiao
    Yuan, Yanping
    Yu, Nanyang
    Ni, Ji
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [5] EXERGY ANALYSIS OF A DX GROUND-SOURCE HEAT PUMP SYSTEM IN XIANGTAN, CHINA
    Yang, Wei
    Zhang, Guoqiang
    Zhou, Jin
    Zhang, Peng
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2187 - 2194
  • [6] A numerical study on performance efficiency of a low-temperature horizontal ground-source heat pump system
    Gao, Wu
    Masum, Shakil
    Qadrdan, Meysam
    Thomas, Hywel Rhys
    [J]. ENERGY AND BUILDINGS, 2023, 291
  • [7] Exergy Analysis of a Ground Source Heat Pump System Under Cooling and Heating Conditions
    Zhao, Lei
    Yuan, Chen
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 799 - 806
  • [8] Energy and exergy analysis of a combined ground source heat pump system
    [J]. Ozturk, M. (muratozturk@sdu.edu.tr), 1600, Elsevier Ltd (73):
  • [9] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753
  • [10] Energy and exergy analysis of a combined ground source heat pump system
    [J]. Ozturk, Murat, 1600, Elsevier Ltd (73):