Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in low-energy test house under simulated occupancy conditions

被引:18
|
作者
Ally, Moonis R. [1 ]
Munk, Jeffrey D. [1 ]
Baxter, Van D. [1 ]
Gehl, Anthony C. [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
Exergy analysis; Energy analysis; Heat pump; Thermodynamics; R410A; Renewable energy; Ground source; EXCHANGERS;
D O I
10.1016/j.ijrefrig.2012.01.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents data, analyses, measures of performance, and conclusions for a ground-source heat pump (GSHP) providing space conditioning to a 345 m(2) house whose envelope is made of structural insulated panels. The entire house thermal load with R-SI-3.7 (R-US-21) walls, triple-pane windows (U-factor of 1.64 W m(-2) K (0.29 Btu h(-1) ft(-2) degrees F-1)) and solar heat gain coefficient of 0.25, a roof assembly with overall thermal resistance of about R-SI-8.8 (R-US-50), and low leakage rates of 0.74 ACH at 50 Pa, was satisfied with a 2.16 ton (7.56 kW) GSHP unit. Coefficient of performance is calculated on the basis of the total power input (including duct, ground loop, and control power losses). Exergy analysis provides a true measure of how closely actual performance approaches the ideal, and it unequivocally identifies, better than energy analysis does, the sources and causes of lost work - the root cause of system inefficiencies and wasted energy. Published by Elsevier Ltd.
引用
收藏
页码:1092 / 1103
页数:12
相关论文
共 39 条
  • [21] Impact of ventilation rates on indoor thermal comfort and energy efficiency of ground-source heat pump system
    Deng, Yelin
    Feng, Zhuangbo
    Fang, Jian
    Cao, Shi-Jie
    SUSTAINABLE CITIES AND SOCIETY, 2018, 37 : 154 - 163
  • [22] ENERGY AND EXERGY ANALYSIS OF AN AIR SOURCE HEAT PUMP UNDER VARIABLE AMBIENT CONDITIONS
    Streckiene, Giedre
    Kropas, Tomas
    Mikucioniene, Ruta
    Dziugaite-Tumeniene, Rasa
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2024, 32 (01) : 12 - 21
  • [23] MODELING AND ANALYSIS OF GROUND-SOURCE HEAT PUMP SYSTEM ON LOW GWP REFRIGERANTS FOR DOMESTIC APPLICATIONS
    Ostapenko, Oleksii
    Yakovleva, Olga
    Khmelniuk, Mykhailo
    Trandafilov, Vladimir
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND COOLANTS, 2017, : 260 - 267
  • [24] Exergy efficiency analysis and energy saving for a water-source heat pump system
    Me, G. Z.
    Li, G. D.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 792 - 796
  • [25] Thermal response test and numerical analysis based on two models for ground-source heat pump system
    Yu, Xiaohui
    Zhang, Yufeng
    Deng, Na
    Wang, Jianshuan
    Zhang, Dongwen
    Wang, Jilin
    ENERGY AND BUILDINGS, 2013, 66 : 657 - 666
  • [26] Experimental energy and exergy analysis of a ground source heat pump and cooling machine in mild climate conditions
    Arslan, Mevlut
    Kavasogullari, Baris
    Yesilyurt, Murat Kadir
    Igci, Atilla Abir
    Sungur, Aysenur
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 42 (03) : 286 - 301
  • [27] Energy and exergy analysis of a ground source heat pump system for a public building in Wuhan, China under different control strategies
    Hu, Pingfang
    Hu, Qiushi
    Lin, Yaolin
    Yang, Wei
    Xing, Lu
    ENERGY AND BUILDINGS, 2017, 152 : 301 - 312
  • [28] Comparison of energy and exergy analysis of fossil plant, ground and air source heat pump building heating system
    Lohani, S. P.
    Schmidt, D.
    RENEWABLE ENERGY, 2010, 35 (06) : 1275 - 1282
  • [29] Thermal comfort assessment and energy consumption analysis of ground-source heat pump system combined with radiant heating/cooling
    Lu, Shikui
    Zhang, Xiaosong
    Journal of Southeast University (English Edition), 2012, 28 (01) : 52 - 57
  • [30] Energy, exergy and exergoeconomic analysis of solar-assisted vertical ground source heat pump system for heating season
    Fatih Ünal
    Galip Temir
    Hasan Köten
    Journal of Mechanical Science and Technology, 2018, 32 : 3929 - 3942