Comparison of an Implantable Middle Ear Microphone and Conventional External Microphone for Cochlear Implants: A Clinical Feasibility Study

被引:1
|
作者
Craddock, Louise C. [1 ]
Hodson, James [1 ,2 ]
Gosling, Amy [1 ]
Cooper, Stacey [1 ]
Morse, Robert P. [3 ]
Begg, Philip [1 ,4 ]
Prokopiou, Andreas [3 ]
Irving, Richard M. [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Birmingham, England
[2] Univ Hosp Birmingham NHS Fdn Trust, Inst Translat Med, Health Data Sci Team, Res Dev & Innovat, Birmingham, England
[3] Univ Warwick, Sch Engn, Coventry, England
[4] Univ Kentucky, Lexington, KY USA
关键词
Audiology; Cochlear implants; Implantable technology; Research trial; Surgical trial;
D O I
10.1097/MAO.0000000000003713
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
ObjectivesAll commercially available cochlear implant (CI) systems use an external microphone and sound processor; however, external equipment carries lifestyle limitations. Although totally implantable devices using subcutaneous microphones have been developed, these are compromised by problems with soft tissue sound attenuation, feedback, and intrusive body noise. This in vivo pilot study evaluates a middle ear microphone (MEM) that aims to overcome these issues and compares hearing performance with that of an external CI microphone.DesignSix adult participants with an existing CI were implanted with a temporary MEM in the contralateral ear. Signals from the MEM were routed via a percutaneous plug and cable to the CI sound processor. Testing was performed in the CI microphone and MEM conditions using a range of audiometric assessments, which were repeated across four visits.ResultsPerformance of the MEM did not differ significantly from that of the CI on the assessments of Auditory Speech Sounds Evaluation loudness scaling at either 250 or 1000 Hz, or in the accuracy of repeating keywords presented at 70 dB. However, the MEM had significantly poorer aided sound-field thresholds, particularly at higher frequencies (>= 4000 Hz), and significantly poorer performance on Arthur Boothroyd words presented at 55 dB, compared with the CI.ConclusionIn this pilot study, the MEM showed comparable performance to that of an external CI microphone across some audiometric assessments. However, performance with the MEM was poorer than the CI in soft-level speech (55 dB) and at higher frequencies. As such, the benefits of MEM need to be considered against the compromises in hearing performance. However, with future development, MEM is a potentially promising technology.
引用
收藏
页码:1162 / 1169
页数:8
相关论文
共 43 条
  • [31] A New Intraoperative Real-time Monitoring System for Reconstructive Middle Ear Surgery: An Experimental and Clinical Feasibility Study
    Zahnert, Thomas
    Metasch, Marie-Luise
    Seidler, Hannes
    Bornitz, Matthias
    Lasurashvili, Nicoloz
    Neudert, Marcus
    OTOLOGY & NEUROTOLOGY, 2016, 37 (10) : 1601 - 1607
  • [32] Comparison of Crestal Bone Loss and Implant Stability Among the Implants Placed With Conventional Procedure and Using Osteotome Technique: A Clinical Study
    Padmanabhan, Thallam Veer
    Gupta, Rajiv Kumar
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (06) : 475 - 483
  • [33] Clinical feasibility study for detection of myocardial oedema by a cine SSFP sequence in comparison to a conventional T2-weighted sequence
    Steen, Henning
    Voss, Frederik
    Andre, Florian
    Neizel, Mirja
    Schaeufele, Tim
    Lehrke, Stephanie
    Lossnitzer, Dirk
    Giannitsis, Evangelos
    Katus, Hugo A.
    CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (02) : 125 - 131
  • [34] Clinical feasibility study for detection of myocardial oedema by a cine SSFP sequence in comparison to a conventional T2-weighted sequence
    Henning Steen
    Frederik Voss
    Florian André
    Mirja Neizel
    Tim Schäufele
    Stephanie Lehrke
    Dirk Lossnitzer
    Evangelos Giannitsis
    Hugo A. Katus
    Clinical Research in Cardiology, 2012, 101 : 125 - 131
  • [35] THE USE OF ALUMINUM-OXIDE (AL2O3) TUBINGEN CERAMIC IMPLANTS IN MIDDLE-EAR SURGERY - A REPORT ON A CLINICAL-STUDY
    ZOLLNER, C
    LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1985, 64 (05): : 233 - 237
  • [36] Comparison of clinical safety and feasibility between reduced-port laparoscopic radical gastrectomy and conventional laparoscopic radical gastrectomy: A retrospective study
    Wang, Liang
    Chen, Xiaoqian
    Ma, Xinfu
    Miao, Wei
    Wang, Cheng
    Yan, Su
    FRONTIERS IN SURGERY, 2022, 9
  • [37] Subtyping of Human Papillomavirus (HPV) Using Next-Generation Sequencing (NGS) Data in Cervical Cancer: A Feasibility Study with Comparison to Conventional Clinical Assays
    Chen, J.
    Lee, Y.
    McNulty, S.
    Pfeifer, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (11): : S43 - S44
  • [38] Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI
    Li, Zhaotong
    Cao, Gan
    Zhang, Li
    Yuan, Jichun
    Li, Sha
    Zhang, Zeru
    Wu, Fengliang
    Gao, Song
    Xia, Jun
    EUROPEAN RADIOLOGY, 2024, 34 (09) : 5783 - 5799
  • [39] Comparison of clinical safety and feasibility between reduced-port laparoscopic radical gastrectomy and conventional laparoscopic radical gastrectomy: A retrospective study (vol 9, 995194, 2022)
    Wang, Liang
    Deng, Yingfang
    Yan, Su
    Ma, Xinfu
    Wang, Cheng
    Miao, Wei
    Chen, Xiaoqian
    FRONTIERS IN SURGERY, 2022, 9
  • [40] Letter to the Editor: "Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI"
    Walston, Shannon Leigh
    Ueda, Daiju
    EUROPEAN RADIOLOGY, 2025, 35 (02) : 592 - 593