Effects of Implant Angulation and Impression Coping Type on the Dimensional Accuracy of Impressions

被引:11
|
作者
Shim, Ji Suk [1 ]
Ryu, Jae Jun [2 ]
Shin, Sang Wan [3 ]
Lee, Jeong Yol [4 ]
机构
[1] Korea Univ, Ansan Hosp, Fac Dent, Dept Prosthodont, Seoul 152703, South Korea
[2] Korea Univ, Anam Hosp, Fac Dent, Dept Prosthodont, Seoul 152703, South Korea
[3] Korea Univ, Guro Hosp, Fac Dent, Dept Prosthodont, Seoul 152703, South Korea
[4] Korea Univ, Guro Hosp, Fac Dent, Dept Adv Prosthodont, Seoul 152703, South Korea
关键词
transfer; pick-up; divergence; CONNECTION; PROSTHESES;
D O I
10.1097/ID.0000000000000336
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:To analyze the accuracy of impressions in relation to implant angulation and type of impression coping. Materials and Methods:Three metal master models with 2 implants of 3 different angulations (parallel, mesiodistal, and buccolingual) were fabricated. Nine groups of experimental models were fabricated to duplicate the 3 master models using 3 types of impression copings: transfer, pick-up, and hybrid. The distance between the analogs for each model was measured using a video measuring system. The influence of angulation and type of impression coping was analyzed by a two-way ANOVA (P < 0.05). Results:There were significant differences in error rates in relation to implant angulation and type of impression coping (P < 0.05). Impressions of buccolingually divergent implants with transfer copings showed statistically higher error rates than other groups (P < 0.05). Conclusions:Buccolingual divergence can be a variable that influences the impression accuracy of transfer copings compared with pick-up and hybrid copings. Hybrid copings demonstrate reasonable reproducibility similar to that of pick-up copings.
引用
下载
收藏
页码:726 / 729
页数:4
相关论文
共 50 条
  • [41] Digital Evaluation of the Dimensional Accuracy of Four Different Implant Impression Techniques
    Ozcelik, T. B.
    Ozcan, I.
    Ozan, O.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (10) : 1247 - 1253
  • [42] The Effect of Implant Connection Length on the Dimensional Impression Accuracy of Inclined Implants
    Ehsani, Sara
    Siadat, Hakimeh
    Alikhasi, Marzieh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E315 - E320
  • [43] The Effect of Impression Technique and Implant Angulation on the Impression Accuracy of External- and Internal-Connection Implants (vol 27, pg 1422, 2012)
    Mpikos, Pavlos
    Kafantaris, Nikolaos
    Tortopidis, Dimitrios
    Galanis, Christos
    Kaisarlis, George
    Koidis, Petros
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 43 - 43
  • [44] Implant overdenture impressions using a dynamic impression concept
    Lee, Byung-Kil
    Park, Sang-Hun
    Lee, Cheong-Hee
    Cho, Jin-Hyun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01): : 66 - 70
  • [45] The influence of the superimposition procedure and type of intraoral impression on the superimposition accuracy of CBCT scans with dental impressions in implant planning: an in-vitro study
    Constantin Motel
    Carolin Kirschner
    Felix Förtsch
    Mayte Buchbender
    Manfred Wichmann
    Ragai-Edward Matta
    International Journal of Implant Dentistry, 11 (1)
  • [46] Effects of impression levels and trays on the accuracy of impressions taken from angulated implants
    Geramipanah, Farideh
    Sahebi, Majid
    Davari, Maryam
    Hajimahmoudi, Mohammadreza
    Rakhshan, Vahid
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (09) : 1098 - 1105
  • [47] Effect of Different Viscosity and Tear Strength of Polyvinyl Siloxane Impression Material on the Accuracy of Dental Implant Impressions
    Haider, Yagthan Mohammed
    Mokhtar, Norehan
    Najim, Zubaida Tariq
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (12): : 101 - 109
  • [48] THE ACCURACY OF IMPLANT IMPRESSIONS: A SYSTEMATIC REVIEW
    Lee, Heeje
    So, Joseph S.
    Hochstedler, J. L.
    Ercoli, Carlo
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (04): : 285 - 291
  • [49] ACCURACY OF IMPRESSION TECHNIQUES IN IMPLANT DENTISTRY
    Alrumi, Bader Abdullah
    al Yami, Ibrahim Mohammed
    Alghamdi, Randah Abdulrhman
    Aldajani, Ali Mohammed
    Alhelaly, Hussein Mohammed
    Mohammed, Abdulrahman Thabet
    Abotaleb, Mohannd Talebalrahman
    Aljuaid, Mohammed Mbearak
    Alotaibi, Jamal Mousa
    Alelyani, Mohammed Dakhil
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1396 - 1402
  • [50] Accuracy of impressions with different impression materials in angulated implants
    Reddy, S.
    Prasad, K.
    Vakil, H.
    Jain, A.
    Chowdhary, R.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2013, 16 (03) : 279 - 284