Continuous Monitoring of Pulsed HIFU Beams Using Dual-mode Ultrasound Array Systems

被引:1
|
作者
Casper, Andrew [1 ]
Ballard, John [2 ]
Liu, Dalong [2 ]
Haritonova, Alyona [1 ]
Ebbini, Emad [2 ]
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
关键词
Phased Arrays; Cavitation; Thermal Therapy;
D O I
10.1063/1.4757307
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have previously described several DMUA prototypes with therapeutic and imaging capabilities suited for image-guided surgery. A fully real-time system capable of intermittent therapy/imaging operation to allow for high frame rate imaging during therapeutic has been developed. This approach allows for real-time characterization of echoes from the target region at the focal spot within milliseconds of the initiation of the therapeutic pHIFU beam. For example, at intensity levels of similar to 8000 W/cm(2) at 1.15 MHz, analysis of echo data pre- and post-beamforming shows spotty transient activity from within the pHIFU focus, indicative of cavitation. Ex vivo tissue samples were exposed to pHIFU beams of durations < 300 ms at intensity levels in the range of 2500 - 8000 W/cm(2) with interruptions to analyze echo data at frame rates from 100 to 2000 fps. Examination of treated tissue samples shows correspondence between the transient echoes and the nature of the induced lesion (when present). Coupled with the DMUA system's ability to refocus the pHIFU beam at > 1000 updates per second, this approach offers the physician a unique capability of modulating the exposure with millisecond resolution. Examples of monitoring and control of single- and multiple-focus DMUA patterns will be presented and discussed.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
  • [21] Dual-mode continuous arrhythmias telemonitoring system
    Amien, Magdi B.M.
    Lin, Jiarui
    Journal of Applied Sciences, 2007, 7 (07) : 965 - 971
  • [22] Auto recalibration based on dual-mode sensing for robust optical continuous glucose monitoring
    Wang, Bing
    Eden, Alexander
    Chen, Yiming
    Kim, Hyunjin
    Queenan, Bridget N.
    Bazan, Guillermo C.
    Pennathur, Sumita
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 418
  • [23] On-line assessment of HIFU beams and lesion monitoring using dual-transducer modes
    Lizzi, FL
    Ketterling, JA
    Muratore, R
    Alam, SK
    Ramachandran, S
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 986 - 989
  • [24] A Dual-Mode Catheter for Cardiac Output Monitoring
    Hou, Shilin
    Zou, Chunxiao
    Li, Yi
    Tang, Hu
    Chen, Siping
    Peng, Jue
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [25] Determining the in-plane and out-of-plane dynamic response of microstructures using pulsed dual-mode ultrasonic array transducers
    Lai, WP
    Fang, WL
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 117 (02) : 186 - 193
  • [26] Dual-mode micromirrors for optical phased array applications
    Krishnamoorthy, U
    Li, K
    Yu, K
    Lee, D
    Heritage, JP
    Solgaard, O
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 97-8 : 21 - 26
  • [27] A Dual-Mode Circular Antenna Array for Indoor Communication
    Wang, Shen-Yun
    Yang, Meng-Ting
    Zhang, Qing
    Kong, Ling-Bing
    Geyi, Wen
    PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2024, 118 : 99 - 105
  • [28] Dual-mode micromirrors for optical phased array applications
    Krishnamoorthy, U
    Li, K
    Yu, K
    Lee, D
    Heritage, JP
    Solgaard, O
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 1294 - 1297
  • [29] A dual-mode orbital angular momentum antenna array
    Yao, Yu
    Liang, Xianling
    Bai, Xudong
    Peng, Zheng
    Qian, Yang
    Geng, Junping
    Jin, Ronghong
    2016 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2016, : 1899 - 1900
  • [30] A pulsed Schlieren system for visualizing beams from phased-array HIFU applicators
    Christensen, Douglas A.