Mesoscale diffusion magnetic resonance imaging of the ex vivo human hippocampus

被引:13
|
作者
Ly, Maria [1 ]
Foley, Lesley [2 ]
Manivannan, Ashwinee [3 ]
Hitchens, T. Kevin [2 ]
Richardson, R. Mark [4 ,5 ,6 ]
Modo, Michel [1 ,5 ,7 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Dept Neurobiol, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Neurosci, Pittsburgh, PA USA
[4] Univ Pittsburgh, Dept Neurol Surg, Pittsburgh, PA 15260 USA
[5] Univ Pittsburgh, McGowan Inst Regenerat Med, 3025 East Carson St, Pittsburgh, PA 15203 USA
[6] Univ Pittsburgh, Inst Brain, Pittsburgh, PA USA
[7] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
关键词
connectome; diffusion tensor imaging; epilepsy; ex vivo; hippocampus; mesoscale; tractography; TO-NOISE RATIO; GRADIENT DIRECTIONS; IN-VIVO; TIME-DEPENDENCE; B-VALUE; 7T MRI; TENSOR; TISSUE; BRAIN; SIGNAL;
D O I
10.1002/hbm.25119
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Mesoscale diffusion magnetic resonance imaging (MRI) endeavors to bridge the gap between macroscopic white matter tractography and microscopic studies investigating the cytoarchitecture of human brain tissue. To ensure a robust measurement of diffusion at the mesoscale, acquisition parameters were arrayed to investigate their effects on scalar indices (mean, radial, axial diffusivity, and fractional anisotropy) and streamlines (i.e., graphical representation of axonal tracts) in hippocampal layers. A mesoscale resolution afforded segementation of the pyramidal cell layer (CA1-4), the dentate gyrus, as well as stratum moleculare, radiatum, and oriens. Using ex vivo samples, surgically excised from patients with intractable epilepsy (n= 3), we found that shorter diffusion times (23.7 ms) with a b-value of 4,000 s/mm(2)were advantageous at the mesoscale, providing a compromise between mean diffusivity and fractional anisotropy measurements. Spatial resolution and sample orientation exerted a major effect on tractography, whereas the number of diffusion gradient encoding directions minimally affected scalar indices and streamline density. A sample temperature of 15 degrees C provided a compromise between increasing signal-to-noise ratio and increasing the diffusion properties of the tissue. Optimization of the acquisition afforded a system's view of intra- and extra-hippocampal connections. Tractography reflected histological boundaries of hippocampal layers. Individual layer connectivity was visualized, as well as streamlines emanating from individual sub-fields. The perforant path, subiculum and angular bundle demonstrated extra-hippocampal connections. Histology of the samples confirmed individual cell layers corresponding to ROIs defined on MR images. We anticipate that this ex vivo mesoscale imaging will yield novel insights into human hippocampal connectivity.
引用
收藏
页码:4200 / 4218
页数:19
相关论文
共 50 条
  • [11] Quantitative magnetic resonance imaging of meniscal pathology ex vivo
    Bae, Won C.
    Tadros, Anthony S.
    Finkenstaedt, Tim
    Du, Jiang
    Statum, Sheronda
    Chung, Christine B.
    SKELETAL RADIOLOGY, 2021, 50 (12) : 2405 - 2414
  • [12] Medial Temporal Cortices in Ex Vivo Magnetic Resonance Imaging
    Augustinack, Jean C.
    van der Kouwe, Andre J. W.
    Fischl, Bruce
    JOURNAL OF COMPARATIVE NEUROLOGY, 2013, 521 (18) : 4177 - 4188
  • [13] High resolution in-vivo diffusion imaging of the human hippocampus
    Treit, Sarah
    Steve, Trevor
    Gross, Donald W.
    Beaulieu, Christian
    NEUROIMAGE, 2018, 182 : 479 - 487
  • [14] CORRELATION OF HISTOLOGIC SECTIONS AND MAGNETIC RESONANCE IMAGING IN EX-VIVO HUMAN PROSTATE SPECIMENS
    Kimm, Simon
    Tarin, Tatum V.
    Lee, Jin Hyung
    Nishimura, Dwight G.
    Jensen, Kristen C.
    Hu, Bob S.
    Lee, Dong S.
    Brooks, James D.
    JOURNAL OF UROLOGY, 2009, 181 (04): : 783 - 783
  • [15] Three-dimensional fiber architecture of the nonpregnant human uterus determined ex vivo using magnetic resonance diffusion tensor imaging
    Weiss, S
    Jaermann, T
    Schmid, P
    Staempfli, P
    Boesiger, P
    Niederer, P
    Caduff, R
    Bajka, M
    ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2006, 288A (01): : 84 - 90
  • [16] High resolution ex vivo magnetic resonance imaging of human coronary arteries: A comparison with intravascular ultrasound imaging
    Shimada, Y
    Courtney, BK
    McConnell, MV
    Stamper, DL
    Giattina, SD
    Brezinski, ME
    Yock, PG
    Fitzgerald, PJ
    Honda, Y
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 77A - 77A
  • [17] Modulating Diffusion-Weighted Magnetic Resonance Imaging for Screening in Oncologic Tertiary Prevention A Prospective Ex Vivo and In Vivo Study
    Dreher, Constantin
    Kuder, Tristan Anselm
    Koenig, Franziska
    Paech, Daniel
    Tavakoli, Andrej
    Laun, Frederik Bernd
    Flothow, Florian
    Gnirs, Regula
    Benkert, Thomas
    Nickel, Dominik
    Strecker, Ralf
    Schlemmer, Heinz-Peter
    Bickelhaupt, Sebastian
    INVESTIGATIVE RADIOLOGY, 2019, 54 (11) : 704 - 711
  • [18] Magnetic resonance imaging during warm ex vivo kidney perfusion
    Schutter, Rianne
    van Varsseveld, Otis C.
    Lantinga, Veerle A.
    Pool, Merel B. F.
    Hamelink, Tim H.
    Potze, Jan Hendrik
    Leuvenink, Henri G. D.
    Laustsen, Christoffer
    Borra, Ronald J. H.
    Moers, Cyril
    ARTIFICIAL ORGANS, 2023, 47 (01) : 105 - 116
  • [19] Ex vivo magnetic resonance imaging of crystalline lens dimensions in chicken
    Tattersall, Rebecca J.
    Prashar, Ankush
    Singh, Krish D.
    Tokarczuk, Pawel F.
    Erichsen, Jonathan T.
    Hocking, Paul M.
    Guggenheim, Jeremy A.
    MOLECULAR VISION, 2010, 16 (18): : 144 - 153
  • [20] Characterization of pulmonary emboli ex vivo by magnetic resonance imaging and ultrasound
    Tratar, Gregor
    Blinc, Ales
    Podbregar, Matej
    Kraij, Eduard
    Balazic, Joze
    Sabovic, Miso
    Sersa, Igor
    THROMBOSIS RESEARCH, 2007, 120 (05) : 763 - 771