Mesoscale diffusion magnetic resonance imaging of the ex vivo human hippocampus

被引:13
|
作者
Ly, Maria [1 ]
Foley, Lesley [2 ]
Manivannan, Ashwinee [3 ]
Hitchens, T. Kevin [2 ]
Richardson, R. Mark [4 ,5 ,6 ]
Modo, Michel [1 ,5 ,7 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Dept Neurobiol, Pittsburgh, PA USA
[3] Univ Pittsburgh, Dept Neurosci, Pittsburgh, PA USA
[4] Univ Pittsburgh, Dept Neurol Surg, Pittsburgh, PA 15260 USA
[5] Univ Pittsburgh, McGowan Inst Regenerat Med, 3025 East Carson St, Pittsburgh, PA 15203 USA
[6] Univ Pittsburgh, Inst Brain, Pittsburgh, PA USA
[7] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
关键词
connectome; diffusion tensor imaging; epilepsy; ex vivo; hippocampus; mesoscale; tractography; TO-NOISE RATIO; GRADIENT DIRECTIONS; IN-VIVO; TIME-DEPENDENCE; B-VALUE; 7T MRI; TENSOR; TISSUE; BRAIN; SIGNAL;
D O I
10.1002/hbm.25119
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Mesoscale diffusion magnetic resonance imaging (MRI) endeavors to bridge the gap between macroscopic white matter tractography and microscopic studies investigating the cytoarchitecture of human brain tissue. To ensure a robust measurement of diffusion at the mesoscale, acquisition parameters were arrayed to investigate their effects on scalar indices (mean, radial, axial diffusivity, and fractional anisotropy) and streamlines (i.e., graphical representation of axonal tracts) in hippocampal layers. A mesoscale resolution afforded segementation of the pyramidal cell layer (CA1-4), the dentate gyrus, as well as stratum moleculare, radiatum, and oriens. Using ex vivo samples, surgically excised from patients with intractable epilepsy (n= 3), we found that shorter diffusion times (23.7 ms) with a b-value of 4,000 s/mm(2)were advantageous at the mesoscale, providing a compromise between mean diffusivity and fractional anisotropy measurements. Spatial resolution and sample orientation exerted a major effect on tractography, whereas the number of diffusion gradient encoding directions minimally affected scalar indices and streamline density. A sample temperature of 15 degrees C provided a compromise between increasing signal-to-noise ratio and increasing the diffusion properties of the tissue. Optimization of the acquisition afforded a system's view of intra- and extra-hippocampal connections. Tractography reflected histological boundaries of hippocampal layers. Individual layer connectivity was visualized, as well as streamlines emanating from individual sub-fields. The perforant path, subiculum and angular bundle demonstrated extra-hippocampal connections. Histology of the samples confirmed individual cell layers corresponding to ROIs defined on MR images. We anticipate that this ex vivo mesoscale imaging will yield novel insights into human hippocampal connectivity.
引用
收藏
页码:4200 / 4218
页数:19
相关论文
共 50 条
  • [1] MAGNETIC RESONANCE IMAGING PARAMETER MAPPING IN EX VIVO HUMAN MENISCI
    Olsson, E.
    Folkesson, E.
    Peterson, P.
    Onnerfjord, P.
    Englund, M.
    Svensson, J.
    OSTEOARTHRITIS AND CARTILAGE, 2018, 26 : S461 - S461
  • [2] Apparatus for histological Validation of In Vivo and Ex Vivo Magnetic Resonance Imaging of the human Prostate
    Bourne, Roger M.
    Bailey, Colleen
    Johnston, Edward William
    Pye, Hayley
    Heavey, Susan
    Whitaker, Hayley
    Siow, Bernard
    Freeman, Alex
    Shaw, Greg L.
    Sridhar, Ashwin
    Mertzanidou, Thomy
    Hawkes, David J.
    Alexander, Daniel C.
    Punwani, Shonit
    Panagiotaki, Eleftheria
    FRONTIERS IN ONCOLOGY, 2017, 7
  • [3] Optimized magnetic resonance diffusion protocol for ex-vivo whole human brain imaging with a clinical scanner
    Scherrer, Benoit
    Afacan, Onur
    Stamm, Aymeric
    Singh, Jolene
    Warfield, Simon K.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [4] The assessment of ex-vivo human pancreata using magnetic resonance imaging
    Khambalia, Hussein
    Zhao, Sha
    van Dellen, David
    Summers, Angela
    Moinuddin, Zia
    Giuffrida, Giuseppe
    Yiannoullou, Petros
    Parker, Geoffrey
    Augustine, Titus
    XENOTRANSPLANTATION, 2015, 22 : S2 - S2
  • [5] THE ASSESSMENT OF EX-VIVO HUMAN PANCREATA USING MAGNETIC RESONANCE IMAGING
    Khambalia, Hussein
    Zhao, Sha
    van Dellen, David
    Summers, Angela
    Moinuddin, Zia
    Giuffrida, Giuseppe
    Yiannoullou, Petros
    Parker, Geoffrey
    Augustine, Titus
    TRANSPLANTATION, 2015, 99 (11) : S2 - S2
  • [6] Magnetic resonance diffusion imaging of the human cervical spinal cord in vivo
    Clark, CA
    Barker, GJ
    Tofts, PS
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (06) : 1269 - 1273
  • [7] In vivo vs. ex vivo magnetic resonance imaging in mice
    MacKenzie-Graham, Allan
    FRONTIERS IN NEUROINFORMATICS, 2012, 6
  • [8] Quantitative magnetic resonance imaging of hepatic steatosis: Validation in ex vivo human livers
    Bannas, Peter
    Kramer, Harald
    Hernando, Diego
    Agni, Rashmi
    Cunningham, Ashley M.
    Mandal, Rakesh
    Motosugi, Utaroh
    Sharma, Samir D.
    del Rio, Alejandro Munoz
    Fernandez, Luis
    Reeder, Scott B.
    HEPATOLOGY, 2015, 62 (05) : 1444 - 1455
  • [9] Quantitative magnetic resonance imaging of meniscal pathology ex vivo
    Won C. Bae
    Anthony S. Tadros
    Tim Finkenstaedt
    Jiang Du
    Sheronda Statum
    Christine B. Chung
    Skeletal Radiology, 2021, 50 : 2405 - 2414
  • [10] Esophageal carcinoma -: Ex vivo endoluminal magnetic resonance imaging
    Stoker, J
    Van Velthuysen, MLF
    Van Overhagen, H
    Van Kempen, D
    Tilanus, HW
    Laméris, JS
    INVESTIGATIVE RADIOLOGY, 1999, 34 (01) : 58 - 64