Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function

被引:129
|
作者
Sailer, Irena [1 ]
Zembic, Anja [1 ]
Jung, Ronald Ernst [1 ]
Siegenthaler, David [1 ]
Holderegger, Claudia [1 ]
Haemmerle, Christoph Hans Franz [1 ]
机构
[1] Univ Zurich, Sch Dent Med, Dept Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland
关键词
ceramic abutments; dental implants; implant abutments; implant reconstruction; titanium abutments; zirconia; FIXED PARTIAL DENTURES; 5-YEAR MULTICENTER; CERAMIC ABUTMENTS; ANTERIOR MAXILLA; SOFT-TISSUE; RESTORATIONS; CROWNS; REPLACEMENT; PROSTHESES; DENTISTRY;
D O I
10.1111/j.1600-0501.2008.01636.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to test whether or not customized zirconia abutments exhibit the same survival rates in canine and posterior regions as titanium abutments, and to compare the esthetic result of the two abutment types. Twenty-two patients with 40 implants in posterior regions were included and the implant sites were randomly assigned to 20 customized zirconia and 20 customized titanium abutments. All-ceramic (AC) and metal-ceramic (MC) crowns were fabricated. In all except two cases, the crowns were cemented on the abutments using resin or glass-ionomer cements. Two zirconia reconstructions were screw retained. At baseline, 6 and 12 months, the reconstructions were examined for technical and biological problems. Probing pocket depth (PPD), plaque (Pl) and bleeding on probing (BOP) were assessed and compared with natural control teeth. Furthermore, the difference of color (Delta E) of the peri-implant mucosa and the gingiva of control teeth was evaluated by means of a spectrophotometer (Spectroshade). The data were analyzed with Student's unpaired t-test, ANOVA and regression analyses. Twenty patients with 19 zirconia and 12 titanium abutments were examined at a mean follow-up of 12.6 +/- 2.7 months. The survival rate for reconstructions and abutments was 100%. No technical or biological problems were found at the test and control sites. Two chippings (16.7%) occurred at crowns supported by titanium abutments. No difference was found regarding PPD (meanPPD(ZrO2) 3.4 +/- 0.7 mm, mPPD(Ti) 3.3 +/- 0.6 mm), Pl (mPl(ZrO2) 0.2 +/- 0.3, mPl(Ti) 0.1 +/- 1.8) and BOP (mBOP(ZrO2) 60 +/- 30%, mBOP(Ti) 30 +/- 40%) between the two groups. Both crowns on zirconia and titanium abutments induced a similar amount of discoloration of the soft tissue compared with the gingiva at natural teeth (Delta E-ZrO2 8.1 +/- 3.9, Delta E-Ti 7.8 +/- 4.3). At 1 year, zirconia abutments exhibited the same survival and a similar esthetic outcome as titanium abutments. To cite this article:Sailer I, Zembic A, Jung RE, Siegenthaler D, Holderegger C, HAmmerle CHF. Randomized controlled clinical trial of customized zirconia and titanium implant abutments for canine and posterior single-tooth implant reconstructions: preliminary results at 1 year of function.Clin. Oral Impl. Res. 20, 2009; 219-225.doi: 10.1111/j.1600-0501.2008.01636.x.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [21] A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant-supported single-tooth restorations
    Hosseini, Mandana
    Worsaae, Nils
    Schiodt, Morten
    Gotfredsen, Klaus
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2011, 4 (04) : 347 - 361
  • [22] Randomized controlled clinical study of veneered zirconia abutments for single implant crowns: Clinical, histological, and microbiological outcomes
    Thoma, Daniel S.
    Sailer, Irena
    Muhlemann, Sven
    Gil, Alfonso
    Jung, Ronald E.
    Hammerle, Christoph H. F.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (06) : 988 - 996
  • [23] Prefabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: evaluation of peri-implant tissues and superstructures after 12 months of function
    Nothdurft, Frank
    Pospiech, Peter
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) : 857 - 865
  • [24] Monolithic zirconia single tooth implant-supported restorations with CAD/CAM titanium abutments in the posterior region: A 1-year prospective case series study
    Donker, Vincent J. J.
    Raghoebar, Gerry M.
    Jensen-Louwerse, Charlotte
    Vissink, Arjan
    Meijer, Henny J. A.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (01) : 125 - 132
  • [25] Randomized Controlled Clinical Trial Comparing Cemented Versus Screw-Retained Single Crowns on Customized Zirconia Abutments: 3-Year Results
    Heierle, Linda
    Wolleb, Karin
    Haemmerle, Christoph H. F.
    Wiedemeier, Daniel B.
    Sailer, Irena
    Thoma, Daniel S.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (02) : 174 - 176
  • [26] Three-Year Results of a Randomized Controlled Clinical Trial Using Submucosally Veneered and Unveneered Zirconia Abutments Supporting All-Ceramic Single-Implant Crowns
    Eisner, Barbara
    Naenni, Nadja
    Husler, Jurg
    Hammerle, Christoph
    Thoma, Daniel
    Sailer, Irena
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (05) : 645 - +
  • [27] All-Ceramic Zirconium Dioxide Implant Abutments for Single-Tooth Replacement in the Posterior Region: A 5-Year Outcome Report
    Nothdurft, Frank P.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (02) : 177 - 181
  • [28] Cemented vs screw-retained zirconia-based single implant reconstructions: A 3-year prospective randomized controlled clinical trial
    Kraus, Riccardo D.
    Epprecht, Alyssa
    Hammerle, Christoph H. F.
    Sailer, Irena
    Thoma, Daniel S.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 578 - 585
  • [29] Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study
    Cosgarea, Raluca
    Gasparik, Cristina
    Dudea, Diana
    Culic, Bogdan
    Dannewitz, Bettina
    Sculean, Anton
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (05) : 537 - 544
  • [30] Randomized Controlled Clinical Trial to Compare Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: One-Year Results
    Cheng, Chih-Wen
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : 15 - 21