Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study

被引:78
|
作者
Cosgarea, Raluca [1 ,2 ,6 ]
Gasparik, Cristina [3 ]
Dudea, Diana [3 ]
Culic, Bogdan [3 ]
Dannewitz, Bettina [4 ,5 ]
Sculean, Anton [6 ]
机构
[1] Univ Marburg, Dept Periodontol, Marburg, Germany
[2] Univ Iuliu Hatieganu, Dept Prosthodont, Cluj Napoca, Romania
[3] Univ Iuliu Hatieganu, Dept Propedeut & Aesthet Dent, Cluj Napoca, Romania
[4] Ruprecht Karl Univ Hosp Heidelberg, Dept Conservat Dent, Sect Periodontol, Clin Oral Dent & Maxillofacial Dis, Heidelberg, Germany
[5] Goethe Univ Frankfurt, Dept Periodontol, Ctr Dent & Oral Med Carolinum, D-60054 Frankfurt, Germany
[6] Univ Bern, Dept Periodontol, Sch Dent, CH-3010 Bern, Switzerland
关键词
implant abutments; mucosa colour; peri-implant soft tissue; titanium; zirconia; SPECTROPHOTOMETRIC ASSESSMENT; CUSTOMIZED ZIRCONIA; OPTICAL PHENOMENON; HUMAN GINGIVA; RESTORATIONS; MUCOSA; DISCOLORATION; STABILITY; REGIONS; CANINE;
D O I
10.1111/clr.12440
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. Materials and methodsEleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences E were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. ResultsCompared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable E both before and after crown cementation. Colour differences around titanium were statistically significant different (P=0.01) only at 1mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P<0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1mm and 2mm from the gingival margin. ConclusionsWithin their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 50 条
  • [1] Comparison of Peri-Implant Soft Tissue Around Zirconia and Titanium Abutments in the Aesthetic Zone: A Narrative Review
    Abu Al-Faraj, Turki M.
    Alsubhi, Bashaer M.
    Almarhoon, Abeer N.
    Almarshoud, Abdulaziz A.
    Alqattan, Mohammed S.
    Alqahtani, Shahad H.
    Al Osaimi, Ahmed A.
    Alshammari, Latifah Saad
    Almakrami, Abdullah I.
    Alwadai, Yazeed S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [2] Influence of anodized titanium abutments on the esthetics of the peri-implant soft tissue: A clinical study
    Wang, Tingting
    Wang, Lina
    Lu, Qianqian
    Fan, Zhen
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 445 - 452
  • [3] Interaction of titanium, zirconia and lithium disilicate with peri-implant soft tissue: study protocol for a randomized controlled trial
    Kuhn, Katharina
    Rudolph, Heike
    Graf, Michael
    Moldan, Matthias
    Zhou, Shaoxia
    Udart, Martin
    Boehmler, Andrea
    Luthardt, Ralph G.
    TRIALS, 2015, 16
  • [4] Interaction of titanium, zirconia and lithium disilicate with peri-implant soft tissue: study protocol for a randomized controlled trial
    Katharina Kuhn
    Heike Rudolph
    Michael Graf
    Matthias Moldan
    Shaoxia Zhou
    Martin Udart
    Andrea Böhmler
    Ralph G. Luthardt
    Trials, 16
  • [5] The integration of peri-implant soft tissues around zirconia abutments: Challenges and strategies
    Tang, Kai
    Luo, Meng-Lin
    Zhou, Wei
    Niu, Li-Na
    Chen, Ji-Hua
    Wang, Fu
    BIOACTIVE MATERIALS, 2023, 27 : 348 - 361
  • [6] Comparison of the effect of zirconia and titanium abutments on peri-implant hard and soft tissues
    Luthra, Sahil
    Sirana, Pallavi
    Pasricha, Neeta
    Issar, Gaurav
    Singla, Neha
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (01): : 69 - 75
  • [7] Effect of different prosthetic abutments on peri-implant soft tissue. A randomized controlled clinical trial
    Ferrari, Marco
    Cagidiaco, Maria Crysanti
    Garcia-Godoy, Franklin
    Goracci, Cecilia
    Cairo, Francesco
    AMERICAN JOURNAL OF DENTISTRY, 2015, 28 (02): : 85 - 89
  • [8] The influence of titanium base abutments on peri-implant soft tissue inflammatory parameters and marginal bone loss: A randomized clinical trial
    Pamato, Saulo
    Honorio, Heitor Marques
    da Costa, Jorge Alexandre
    Traebert, Jefferson Luiz
    Bonfante, Estevam Augusto
    Pereira, Jefferson Ricardo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 542 - 548
  • [9] Revisiting peri-implant soft tissue - histopathological study of the peri-implant soft tissue
    Silva, Eduarda
    Felix, Sergio
    Rodriguez-Archilla, Alberto
    Oliveira, Pedro
    dos Santos, Jose Martins
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (02): : 611 - 618
  • [10] No evidence of difference in discoloration of peri-implant soft tissue between zirconia and other material abutments
    Brignardello-Petersen, Romina
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2018, 149 (09): : E129 - E129