Peri-implant soft tissue colour around titanium and zirconia abutments: a prospective randomized controlled clinical study

被引:78
|
作者
Cosgarea, Raluca [1 ,2 ,6 ]
Gasparik, Cristina [3 ]
Dudea, Diana [3 ]
Culic, Bogdan [3 ]
Dannewitz, Bettina [4 ,5 ]
Sculean, Anton [6 ]
机构
[1] Univ Marburg, Dept Periodontol, Marburg, Germany
[2] Univ Iuliu Hatieganu, Dept Prosthodont, Cluj Napoca, Romania
[3] Univ Iuliu Hatieganu, Dept Propedeut & Aesthet Dent, Cluj Napoca, Romania
[4] Ruprecht Karl Univ Hosp Heidelberg, Dept Conservat Dent, Sect Periodontol, Clin Oral Dent & Maxillofacial Dis, Heidelberg, Germany
[5] Goethe Univ Frankfurt, Dept Periodontol, Ctr Dent & Oral Med Carolinum, D-60054 Frankfurt, Germany
[6] Univ Bern, Dept Periodontol, Sch Dent, CH-3010 Bern, Switzerland
关键词
implant abutments; mucosa colour; peri-implant soft tissue; titanium; zirconia; SPECTROPHOTOMETRIC ASSESSMENT; CUSTOMIZED ZIRCONIA; OPTICAL PHENOMENON; HUMAN GINGIVA; RESTORATIONS; MUCOSA; DISCOLORATION; STABILITY; REGIONS; CANINE;
D O I
10.1111/clr.12440
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. Materials and methodsEleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences E were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. ResultsCompared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable E both before and after crown cementation. Colour differences around titanium were statistically significant different (P=0.01) only at 1mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P<0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1mm and 2mm from the gingival margin. ConclusionsWithin their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium.
引用
收藏
页码:537 / 544
页数:8
相关论文
共 50 条
  • [31] Anchorage miniscrews: A histologic study of peri-implant soft tissue
    Sebbar, Mourad
    Bourzgui, Farid
    Badre, Latifa
    El Quars, Farid
    INTERNATIONAL ORTHODONTICS, 2012, 10 (01) : 85 - 95
  • [32] Peri-implant bone level around implants with platform-switched abutments:: Preliminary data from a prospective study
    Huerzeler, Markus
    Fickl, Stefan
    Zuhr, Otto
    Wachtel, Hannes C.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (07) : 33 - 39
  • [33] Early bacterial colonization and soft tissue health around zirconia and titanium abutments: an in vivo study in man
    van Brakel, Ralph
    Cune, Marco S.
    van Winkelhoff, Arie Jan
    de Putter, Cornelis
    Verhoeven, Jan Willem
    van der Reijden, Wil
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) : 571 - 577
  • [34] Effect of Soft Tissue Condition on Peri-implant Health and Disease: A Retrospective Clinical Study
    Kadkhodazadeh, Mahdi
    Amid, Reza
    Moscowchi, Anahita
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2022, 42 (02) : E51 - E58
  • [35] Ligature-Induced Peri-implant Bone Loss Around Loaded Zirconia and Titanium Implants
    Roehling, Stefan
    Gahlert, Michael
    Janner, Simone
    Meng, Bo
    Woelfler, Henriette
    Cochran, David L.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 357 - 365
  • [36] Effect of customized healing abutments on the peri-implant linear and volumetric tissue changes at maxillary immediate implant sites: A 1-year prospective randomized clinical trial
    Fernandes, Danilo
    Nunes, Silvia
    Lopez-Castro, Gonzalo
    Marques, Tiago
    Montero, Javier
    Borges, Tiago
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) : 745 - 757
  • [37] Peri-implant soft tissue analyses comparing Ti and ZrO2 abutments: an animal study on beagle dogs
    Blanco, Juan
    Caneiro, Leticia
    Linares, Antonio
    Batalla, Pilar
    Munoz, Fernando
    Ramos, Isabel
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (10) : 1221 - 1226
  • [38] Long-term stability of peri-implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri-implant soft tissues. Summary and consensus statements. The 4th EAO Consensus Conference 2015
    Sicilia, Alberto
    Quirynen, Marc
    Fontolliet, Alain
    Francisco, Helena
    Friedman, Anton
    Linkevicius, Tomas
    Lutz, Rainer
    Meijer, Henny J.
    Rompen, Eric
    Rotundo, Roberto
    Schwarz, Frank
    Simion, Massimo
    Teughels, Wim
    Wennerberg, Ann
    Zuhr, Otto
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 : 148 - 152
  • [39] Clinical and volumetric analysis of peri-implant soft tissue augmentation using an acellular dermal matrix: A prospective cohort study
    Papi, Piero
    Penna, Diego
    Di Murro, Bianca
    Pompa, Giorgio
    JOURNAL OF PERIODONTOLOGY, 2021, 92 (06) : 803 - 813
  • [40] Electron Microscopy (EM) Analysis of Collagen Fibers in the Peri-Implant Soft Tissues around Two Different Abutments
    Covani, Ugo
    Giammarinaro, Enrica
    Di Pietro, Natalia
    Boncompagni, Simona
    Rastelli, Giorgia
    Romasco, Tea
    Velasco-Ortega, Eugenio
    Jimenez-Guerra, Alvaro
    Iezzi, Giovanna
    Piattelli, Adriano
    Marconcini, Simone
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (09)