Optimization of intensity-modulated very high energy (50-250 MeV) electron therapy

被引:43
|
作者
Yeboah, C [1 ]
Sandison, GA
Moskvin, V
机构
[1] Tom Baker Canc Clin, Dept Med Phys, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 1N4, Canada
[3] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[4] Indiana Univ, Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 08期
关键词
D O I
10.1088/0031-9155/47/8/305
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work evaluates the potential of very high energy (50-250 MeV) electron beams for dose conformation and identifies those variables that influence optimized dose distributions for this modality. Intensity-modulated plans for a prostate cancer model were optimized as a function of the importance factors, beam energy and number of energy bins, number of beams, and the beam orientations. A trial-and-error-derived constellation of importance factors for target and sensitive structures to achieve good conformal dose distributions was 500, 50, 10 and I for the target, rectum, bladder and normal tissues respectively. Electron energies greater than 100 MeV were found to be desirable for intensity-modulated very high energy electron therapy (VHEET) of prostate cancer. Plans generated for lower energy beams had relatively poor conformal dose distributions about the target region and delivered high doses to sensitive structures. Fixed angle beam treatments utilizing a large number of fields in the range 9-21 provided acceptable plans. Using more than 21 beams at fixed gantry angles had an insignificant effect on target coverage, but resulted in an increased dose to sensitive structures and an increased normal tissue integral dose, Minor improvements in VHEET plans utilizing a 'small' number (less than or equal to9) of beams may be achieved if, in addition to intensity modulation, energy modulation is implemented using a small number (less than or equal to3) of beam energies separated by 50 to 100 MeV. Rotation therapy provided better target dose homogeneity but unfortunately resulted in increased rectal dose. bladder dose and normal tissue integral dose relative to the 21-field fixed angle treatment plan. Modulation of the beam energy for rotation therapy had no beneficial consequences on the optimized dose distributions. Lastly, selection of beam orientations influenced the optimized treatment plan even when a large number of beams (approximately 15) were employed.
引用
收藏
页码:1285 / 1301
页数:17
相关论文
共 50 条
  • [1] Very High Energy Electrons (50-250 MeV) And Radiation Therapy
    Papiez, Lech
    DesRosiers, Colleen
    Moskvin, Vadim
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2002, 1 (02) : 105 - 110
  • [2] Proton energy optimization and reduction for intensity-modulated proton therapy
    Cao, Wenhua
    Lim, Gino
    Liao, Li
    Li, Yupeng
    Jiang, Shengpeng
    Li, Xiaoqiang
    Li, Heng
    Suzuki, Kazumichi
    Zhu, X. Ronald
    Gomez, Daniel
    Zhang, Xiaodong
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21): : 6341 - 6354
  • [3] High Fidelity Robust Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E641 - E641
  • [4] Energy spectrum of 50-250 MeV/nucleon iron nuclei inside the MIR space craft
    Günther, W
    Leugner, D
    Becker, E
    Heinrich, W
    Reitz, G
    RADIATION MEASUREMENTS, 2002, 35 (05) : 511 - 514
  • [5] Intensity-modulated radiotherapy: Optimized plan comparison for proton, very-high energy electron, and photon beams
    Yeboah, C
    Sandison, G
    MEDICAL PHYSICS, 2002, 29 (06) : 1283 - 1283
  • [6] Optimization of intensity-modulated radiation therapy with biological objectives
    Olafsson, A
    Jeraj, R
    Wright, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22): : 5357 - 5379
  • [7] Energy- and intensity-modulated electron beams for radiotherapy
    Ma, CM
    Pawlicki, T
    Lee, MC
    Jiang, SB
    Li, JS
    Deng, J
    Yi, B
    Mok, E
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2293 - 2311
  • [8] Iterative regularization in intensity-modulated radiation therapy optimization
    Carlsson, F
    Forsgren, A
    MEDICAL PHYSICS, 2006, 33 (01) : 225 - 234
  • [9] Issues in optimization for planning of intensity-modulated radiation therapy
    Verhey, LJ
    SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 210 - 218
  • [10] Dose rate optimization for intensity-modulated arc therapy
    Goldman, P.
    Chen, J.
    Wong, E.
    Battista, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2089 - 2089