Purpose: To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique. Materials and Methods: Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed. Results: The mean preoperative UDVA for all eyes was 1.36 +/- 0.64 logMAR. At 12 months, the mean UDVA was 0.51 +/- 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 +/- 0.29 logMAR, which improved to 0.23 +/- 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 +/- 4.69 diopters (D) preoperatively to -1.26 +/- 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 +/- 3.72 D to 44.43 +/- 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 +/- 3.12 to 4.21 +/- 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery. Conclusion: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 50 条
  • [31] Keratoconus correction using a new model of intrastromal corneal ring segments
    Israel, Marina
    Yousif, Mohamed O.
    Osman, Nermin A.
    Nashed, Marina
    Abdelfattah, Nizar S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (03): : 444 - 454
  • [32] Deep corneal neovascularization after implantation with intrastromal corneal ring segments
    Al-Torbak, A
    Al-Amri, A
    Wagoner, MD
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (05) : 926 - 927
  • [33] Intrastromal corneal ring segments: effect of depth of implantation in visual, refractive, and topographic outcomes in patients with keratoconus
    Cruz, Carlos Neves
    Franqueira, Nuno
    Mendes, Jose Carlos
    Oliveira, Mariana
    Monteiro, Tiago
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (09): : 949 - 955
  • [34] Intrastromal Corneal Ring Segments Implantation in Patients With Keratoconus: 10-Year Follow-Up
    Torquetti, Leonardo
    Ferrara, Guilherme
    Almeida, Franklin
    Cunha, Leandro
    Araujo, Luana P. N.
    Machado, Aydano P.
    Lyra, Joao Marcelo
    Merayo-Lloves, Jesus
    Ferrara, Paulo
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (01) : 22 - U23
  • [35] Intrastromal Corneal Ring Segments and Keratoconus Progression: A Case Series Study
    Benito-Pascual, Blanca
    Arriola-Villalobos, Pedro
    Rodriguez-Quet, Olivia
    Termine, Vittoria
    Cuina-Sardina, Ricardo
    Diaz-Valle, David
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2025, 51 (02): : 65 - 69
  • [36] Acute corneal hydrops after intrastromal corneal ring segment implantation for keratoconus
    Gueell, Jose L.
    Verdaguer, Paula
    Elies, Daniel
    Gris, Oscar
    Manero, Felicidad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2192 - 2195
  • [37] Effectiveness of Intrastromal Corneal Ring Implantation in the Treatment of Adult Patients With Keratoconus: A Systematic Review
    Izquierdo, Luis, Jr.
    Mannis, Mark J.
    Mejias Smith, Josefina A.
    Henriquez, Maria A.
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) : 191 - +
  • [38] Confocal microscopy after implantation of intrastromal corneal ring segments
    Ruckhofer, J
    Böhnke, M
    Alzner, E
    Grabner, G
    OPHTHALMOLOGY, 2000, 107 (12) : 2144 - 2151
  • [39] INTACS Followed by KeraRing Intrastromal Corneal Ring Segment Implantation for Keratoconus
    Coskunseven, Efekan
    Kymionis, George D.
    Grentzelos, Michael A.
    Karavitaki, Alexandra E.
    Portaliou, Dimitra M.
    Jankov, Mirko R., II
    Arslan, Ebru
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 371 - 374
  • [40] Intrastromal corneal ring segment implantation by femtosecond laser for keratoconus correction
    Shabayek, Mohamed H.
    Alio, Jorge L.
    OPHTHALMOLOGY, 2007, 114 (09) : 1643 - 1652