Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique

被引:9
|
作者
Tunc, Zeki [1 ]
Helvacioglu, Firat [1 ]
Sencan, Sadik [1 ]
机构
[1] Maltepe Univ, Sch Med, Dept Ophthalmol, Istanbul, Turkey
关键词
Intrastromal corneal ring segments; keraring; keratoconus; FEMTOSECOND LASER; TREATING KERATOCONUS; INTACS INSERTS; FOLLOW-UP; MANAGEMENT; ECTASIA; EYE;
D O I
10.4103/0301-4738.109519
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique. Materials and Methods: Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed. Results: The mean preoperative UDVA for all eyes was 1.36 +/- 0.64 logMAR. At 12 months, the mean UDVA was 0.51 +/- 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 +/- 0.29 logMAR, which improved to 0.23 +/- 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 +/- 4.69 diopters (D) preoperatively to -1.26 +/- 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 +/- 3.72 D to 44.43 +/- 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 +/- 3.12 to 4.21 +/- 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery. Conclusion: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
引用
收藏
页码:218 / 225
页数:8
相关论文
共 50 条
  • [1] Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique
    Tunc, Zeki
    Helvacioglu, Firat
    Sencan, Sadik
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2011, 59 (06) : 436 - 442
  • [2] Intrastromal Corneal Ring Segment Implantation for the Treatment of Keratoconus
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Cinar, Yasin
    Koytak, Arif
    Kurnaz, Ekrem
    Ozerturk, Yusuf
    CORNEA, 2011, 30 (01) : 11 - 17
  • [3] Vertical versus oblique implantation of intrastromal corneal ring segments for keratoconus
    Sedaghat, Mohamadreza
    Zarei-Ghanavati, Mehran
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01): : 161 - 165
  • [4] Combination of corneal crosslinking and intrastromal corneal ring segments for the treatment of keratoconus
    Zhang, Zhen-Yong
    Zhang, Xing-Ru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1878 - 1879
  • [5] Intrastromal corneal ring segments for management of keratoconus
    Ganesh, Sri
    Shetty, Rohit
    D'Souza, Sharon
    Ramachandran, Sarika
    Kurian, Mathew
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) : 451 - 455
  • [6] Additional Intrastromal Corneal Ring Segments in Keratoconus
    Hashemi, Hassan
    Nabavi, Amin
    Bayat, Reza
    Mohebbi, Masoumeh
    CORNEA, 2018, 37 (05) : 574 - 579
  • [7] Intrastromal corneal ring segments for treating keratoconus
    Zadnik, Karla
    Money, Sarah
    Lindsley, Kristina
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (05):
  • [8] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [9] Tomographic Findings After Implantation of Ferrara Intrastromal Corneal Ring Segments in Keratoconus
    Lyra, Joao Marcelo
    Lyra, Daniela
    Ribeiro, Guilherme
    Torquetti, Leonardo
    Ferrara, Paulo
    Machado, Aydano
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (02) : 110 - +
  • [10] Intrastromal Corneal Ring Segments: How Successful is the Surgical Treatment of Keratoconus?
    Alio, Jorge L.
    Vega-Estrada, Alfredo
    Esperanza, Santiago
    Barraquer, Rafael I.
    Teus, Miguel A.
    Murta, Joaquim
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (01) : 3 - 9