Performance evaluation of the Pima™ point-of-care CD4 analyser using capillary blood sampling in field tests in South Africa

被引:68
|
作者
Glencross, Deborah K. [1 ,3 ]
Coetzee, Lindi M. [1 ,3 ]
Faal, Mamsallah [2 ]
Masango, Martin [4 ]
Stevens, Wendy S. [1 ,3 ]
Venter, W. D. Francois [2 ]
Osih, Regina [2 ]
机构
[1] Univ Witwatersrand, Fac Hlth Sci, Dept Mol Med & Haematol, ZA-2198 Johannesburg, South Africa
[2] Univ Witwatersrand, Wits Reprod Hlth & HIV Inst, ZA-2198 Johannesburg, South Africa
[3] Natl Hlth Lab Serv S Africa, ZA-2198 Parktown, South Africa
[4] Soc Family Hlth New Start HCT HIV Counselling & T, Cape Town, South Africa
关键词
EXTERNAL QUALITY ASSESSMENT; LABORATORY MEDICINE; MOBILE SERVICES; HIV; STRATEGIES; DIAGNOSIS; COUNTS; ERROR; MODEL; AIDS;
D O I
10.1186/1758-2652-15-3
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: Point-of-care CD4 testing can provide immediate CD4 reporting at HIV-testing sites. This study evaluated performance of capillary blood sampling using the point-of-care Pima (TM) CD4 device in representative primary health care clinics doing HIV testing. Methods: Prior to testing, prescribed capillary-sampling and instrument training was undertaken by suppliers across all sites. Matching venous EDTA samples were drawn throughout for comparison to laboratory predicate methodology (PLG/CD4). In Phase I, Pima (TM) cartridges were pipette-filled with EDTA venous blood in the laboratory (N = 100). In Phase II (N = 77), Pima (TM) CD4 with capillary sampling was performed by a single operator in a hospital-based antenatal clinic. During subsequent field testing, Pima (TM) CD4 with capillary sampling was performed in primary health care clinics on HIV-positive patients by multiple attending nursing personnel in a rural clinic (Phase-IIIA, N = 96) and an inner-city clinic (Phase-IIIB, N = 139). Results: Pima (TM) CD4 compared favourably to predicate/CD4 when cartridges were pipette-filled with venous blood (bias -17.3 +/- STDev = 36.7 cells/mm(3); precision-to-predicate %CV < 6%). Decreased precision of Pima (TM) CD4 to predicate/CD4 (varying from 17.6 to 28.8%SIM CV; mean bias = 37.9 +/- STDev = 179.5 cells/mm(3)) was noted during field testing in the hospital antenatal clinic. In the rural clinic field-studies, unacceptable precision-to-predicate and positive bias was noted (mean 28.4%SIM CV; mean bias = +105.7 +/- STDev = 225.4 cells/mm(3)). With additional proactive manufacturer support, reliable performance was noted in the subsequent inner-city clinic field study where acceptable precision-to-predicate (11%SIM CV) and less bias of Pima (TM) to predicate was shown (BA bias similar to 11 +/- STDev = 69 cells/mm(3)). Conclusions: Variable precision of Pima (TM) to predicate CD4 across study sites was attributable to variable capillary sampling. Poor precision was noted in the outlying primary health care clinic where the system is most likely to be used. Stringent attention to capillary blood collection technique is therefore imperative if technologies like Pima (TM) are used with capillary sampling at the POC. Pima (TM) CD4 analysis with venous blood was shown to be reproducible, but testing at the point of care exposes operators to biohazard risk related to uncapping vacutainer samples and pipetting of blood, and is best placed in smaller laboratories using established principles of Good Clinical Laboratory Practice. The development of capillary sampling quality control methods that assure reliable CD4 counts at the point of care are awaited.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [31] Laboratory-based performance evaluation of PIMA CD4+T-lymphocyte count point-of-care by lay-counselors in Kenya
    Zeh, Clement
    Rose, Charles E.
    Inzaule, Seth
    Desai, Mitesh A.
    Otieno, Fredrick
    Humwa, Felix
    Akoth, Benta
    Omolo, Paul
    Chen, Robert T.
    Kebede, Yenew
    Samandari, Taraz
    JOURNAL OF IMMUNOLOGICAL METHODS, 2017, 448 : 44 - 50
  • [32] Evaluation of HIV PIMA™CD4 point-of-care test operation by trained non-health workers in rural health centres in Chiradzulu District, Malawi
    Schramm, Birgit
    Tayea, Aliaa
    Wolters, Liselotte
    Nicholas, Sarala
    Masiku, Charlie Willy
    Zolowere, Dawie Baxter
    Mhango, Eustice
    Kandulu, James Raphael
    Etard, Jean-Francois
    Amaros, Isabel
    Szumilin, Elisabeth
    Gueguen, Monique
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2015, 18
  • [33] CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems
    Wade, Djibril
    Diaw, Papa Alassane
    Daneau, Geraldine
    Camara, Makhtar
    Dieye, Tandakha Ndiaye
    Mboup, Souleymane
    Kestens, Luc
    PLOS ONE, 2013, 8 (09):
  • [34] Performance characteristics of an instrument-free point-of-care CD4 test (VISITECT®CD4) for use in resource-limited settings
    Vidhyavathi, Vairamohan
    Iqbal, Hussain Syed
    Kanthamani, Kannaiyan
    Solomon, Sunil Suhas
    Nandagopal, Paneerselvam
    Luchters, Stanley
    Pham, Minh D.
    Forbes, James
    Crowe, Suzanne M.
    McMurran, Christopher
    Anderson, David A.
    Balakrishnan, Pachamuthu
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (09)
  • [35] Impact on ART initiation of point-of-care CD4 testing at HIV diagnosis among HIV-positive youth in Khayelitsha, South Africa
    Patten, Gabriela E. M.
    Wilkinson, Lynne
    Conradie, Karien
    Isaakidis, Petros
    Harries, Anthony D.
    Edginton, Mary E.
    De Azevedo, Virginia
    van Cutsem, Gilles
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2013, 16
  • [36] Field evaluation of HIV point-of-care testing for early infant diagnosis in Cape Town, South Africa
    Dunning, Lorna
    Kroon, Max
    Hsiao, Nei-yuan
    Myer, Landon
    PLOS ONE, 2017, 12 (12):
  • [37] Field Evaluation of Performance of Alere and Cepheid Qualitative HIV Assays for Pediatric Point-of-Care Testing in an Academic Hospital in Soweto, South Africa
    Murray, Tanya Y.
    Sherman, Gayle G.
    Nakwa, Firdose
    MacLeod, William B.
    Sipambo, Nosisa
    Velaphi, Sithembiso
    Carmona, Sergio
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (11) : 3227 - 3235
  • [38] Evaluation of Portable Point-of-Care CD4 Counter with High Sensitivity for Detecting Patients Eligible for Antiretroviral Therapy
    Manabe, Yukari C.
    Wang, Yaping
    Elbireer, Ali
    Auerbach, Brandon
    Castelnuovo, Barbara
    PLOS ONE, 2012, 7 (04):
  • [39] A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries
    Gils, Tinne
    Hella, Jerry
    Jacobs, Bart K. M.
    Sossen, Bianca
    Mukoka, Madalo
    Muyoyeta, Monde
    Nakabugo, Elizabeth
    Van Nguyen, Hung
    Ubolyam, Sasiwimol
    Mace, Aurelien
    Vermeulen, Marcia
    Nyangu, Sarah
    Sanjase, Nsala
    Sasamalo, Mohamed
    Dinh, Huong Thi
    Ngo, The Anh
    Manosuthi, Weerawat
    Jirajariyavej, Supunnee
    Denkinger, Claudia M.
    Nguyen, Nhung Viet
    Avihingsanon, Anchalee
    Nakiyingi, Lydia
    Szekely, Rita
    Kerkhoff, Andrew D.
    MacPherson, Peter
    Meintjes, Graeme
    Reither, Klaus
    Ruhwald, Morten
    JOURNAL OF INFECTIOUS DISEASES, 2024,
  • [40] Performance evaluation of BD FACSPresto™ point of care CD4 analyzer to enumerate CD4 counts for monitoring HIV infected individuals in Nigeria
    Negedu-Momoh, Olubunmi Ruth
    Jegede, Feyisayo Ebenezer
    Yakubu, Ali
    Balogun, Oluseyi
    Abdullahi, Musa
    Badru, Titilope
    Oladele, Edward Adekola
    Agbakwuru, Chinedu
    Khamofu, Hadiza
    Torpey, Kwasi
    PLOS ONE, 2017, 12 (05):