First neutronics analysis for ITER bio-shield equatorial port plug

被引:5
|
作者
Dang, Tongqiang [1 ,2 ]
Ying, Dongchuan [2 ]
Yang, Qi [1 ,2 ]
Loughlin, Michael [3 ]
Davis, Andrew [4 ]
机构
[1] Univ Sci & Technol China, Sch Nucl Sci & Technol, Hefei 230027, Anhui, Peoples R China
[2] Chinese Acad Sci, Inst Nucl Energy Safety Technol, Hefei 230027, Anhui, Peoples R China
[3] ITER Org, F-13115 St Paul Les Durance, France
[4] EURATOM CCFE Fus Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
关键词
ITER; Bio-shield plug; Port cell; Gamma dose rate; CAD-based Multi-Functional 4D Neutronics; Simulation System; DESIGN;
D O I
10.1016/j.fusengdes.2012.03.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
ITER equatorial port cell outside the bio-shield plug is a place to allow personnel access after shutdown that accommodates various sensitive equipment and pipes. Gamma dose rate after shutdown of 1 day in the port cell should be within 10 mu Sv/h for occupational safety which is one order of magnitude less than that in the port interspace by the shielding of bio-shield plug. To verify the shielding property of the bio-shield plug, the distributions of gamma dose rates in port cell were studied. Based on the ITER neutronics model Alite4 which is a three-dimensional ITER tokomak neutronics model for MCNP calculations with a 40 degree extent in the toroidal direction and vertical reflecting bounded planes on both sides, the equatorial port was updated according to a conceptual CAD model using Monte Carlo Automatic Modeling Program for Radiation Transport Simulation (MCAM). A 2-step method of gamma dose rate calculation was used for shutdown dose rates in CAD-based Multi-Functional 4D Neutronics Simulation System (VisualBUS). The result showed that gamma dose rates in the port cell were higher than the desired limit. Refinements to the bio-shield plug design were suggested to ensure that dose rates in the port cell were within the design value for maintenance access. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1447 / 1452
页数:6
相关论文
共 50 条
  • [31] Preliminary Thermal Mechanical Analysis of the Equatorial Thermal Shield for ITER
    雷明准
    宋云涛
    杜世俊
    叶民友
    奚维斌
    刘旭峰
    刘辰
    Plasma Science and Technology, 2012, 14 (10) : 932 - 935
  • [32] Preliminary Thermal Mechanical Analysis of the Equatorial Thermal Shield for ITER
    Lei Mingzhun
    Song Yuntao
    Du Shijun
    Ye Minyou
    Xi Weibin
    Liu Xufeng
    Liu Chen
    PLASMA SCIENCE & TECHNOLOGY, 2012, 14 (10) : 932 - 935
  • [33] Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system
    Tanchuk, Victor
    Grigoriev, Sergey
    Lyublin, Boris
    Maquet, Philippe
    Senik, Konstantin
    Pak, Sunil
    Udintsev, Victor
    FUSION ENGINEERING AND DESIGN, 2016, 109 : 207 - 212
  • [34] Nuclear analysis of ITER Test Blanket Module Port Plug
    Villari, Rosaria
    Kim, Byoung Yoon
    Barabash, Vladimir
    Giancarli, Luciano
    Levesy, Bruno
    Loughlin, Michael
    Merola, Mario
    Moro, Fabio
    Pascal, Romain
    Petrizzi, Luigino
    Polunovsky, Eduard
    Van der Laan, Jaap G.
    FUSION ENGINEERING AND DESIGN, 2015, 98-99 : 1668 - 1673
  • [35] Optimization of the Integrated Diagnostics in Equatorial Port Plug #3 of ITER for Minimal Interspace Dose Rate
    Youssef, Mahmoud Z.
    Feder, Russell E.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (05) : 1413 - 1420
  • [36] ITER diagnostic port plug engineering design analysis in the EU
    Ciattaglia, E.
    Ingesson, L. C.
    Campbell, D.
    Saibene, G.
    Walker, C.
    Doceu, L.
    Dirken, P.
    Petrizzi, L.
    Heidinger, R.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1231 - 1237
  • [37] Design and Analysis Progress of ITER Diagnostic Equatorial Port #09
    Zhai, Yuhu
    Basile, Allan
    Feder, R.
    Wang, W.
    Chen, Jingping
    Khodak, Andrei
    Klabacha, Jonathan Paul
    Johnson, D.
    Hause, M.
    Messineo, M.
    Zhang, Han
    Gonzalez-Teodoro, Jorge Rafael
    Guirao, Julio
    Iglesias, Silvia
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) : 1254 - 1261
  • [38] EM Loads on ITER Diagnostics Equatorial Port Plug 9 and Its In-Port Components During Plasma Disruptions
    Chen, Jingping
    Zhai, Yuhu
    Feder, Russell
    FUSION SCIENCE AND TECHNOLOGY, 2017, 72 (04) : 686 - 691
  • [39] Analysis of the radioactivity in bio-shield of Kori NPP unit 1 via computational simulation
    Lee, Hyeonmin
    Lee, Jaeho
    Choi, Woo Nyun
    Yoon, Seungbin
    Kim, Hee Reyoung
    PROGRESS IN NUCLEAR ENERGY, 2024, 169
  • [40] Engineering studies for integration of the test blanket module (TBM) systems inside an ITER equatorial port plug
    Madeleine, S.
    Saille, A.
    Martins, J. -R
    Salavy, J. -F.
    Jonqueres, N.
    Rampal, G.
    Bede, O.
    Neuberger, H.
    Boccaccini, L.
    Doceul, L.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1233 - 1237