Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
被引:226
|
作者:
Huckins, JN
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Huckins, JN
Petty, JD
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Petty, JD
Orazio, CE
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Orazio, CE
Lebo, JA
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Lebo, JA
Clark, RC
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Clark, RC
Gibson, VL
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Gibson, VL
Gala, WR
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Gala, WR
Echols, KR
论文数: 0引用数: 0
h-index: 0
机构:US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
Echols, KR
机构:
[1] US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
[2] Chevron Res & Technol Co, Richmond, CA 94802 USA
The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(S)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected R-S values for PP PAHs ranged from approximate to 1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K-OW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R-S values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 degrees C) on R-S values appeared to be complex but were relatively small.
机构:
Korea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 136713, South KoreaKorea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 136713, South Korea
Kim, Pil-Gon
Roh, Ji-Yeon
论文数: 0引用数: 0
h-index: 0
机构:
Korea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 136713, South KoreaKorea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 136713, South Korea
Roh, Ji-Yeon
Hong, Yongseok
论文数: 0引用数: 0
h-index: 0
机构:
Daegu Univ, Dept Environm Engn, 201 Daegudae Ro, Gyongsan 38453, Gyeongsangbuk D, South KoreaKorea Univ, Div Environm Sci & Ecol Engn, 145 Anam Ro, Seoul 136713, South Korea
机构:
Dickinson Coll, Dept Chem, POB 1773, Carlisle, PA 17013 USADickinson Coll, Dept Chem, POB 1773, Carlisle, PA 17013 USA
Witter, Amy E.
Nguyen, Minh H.
论文数: 0引用数: 0
h-index: 0
机构:
Dickinson Coll, Dept Chem, POB 1773, Carlisle, PA 17013 USA
Univ Penn, Dept Chem, Philadelphia, PA 19104 USADickinson Coll, Dept Chem, POB 1773, Carlisle, PA 17013 USA