Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water

被引:226
|
作者
Huckins, JN
Petty, JD
Orazio, CE
Lebo, JA
Clark, RC
Gibson, VL
Gala, WR
Echols, KR
机构
[1] US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
[2] Chevron Res & Technol Co, Richmond, CA 94802 USA
关键词
D O I
10.1021/es990440u
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but very little sampling rate data are available for the estimation of ambient contaminant concentrations from analyte levels in exposed SPMDs. We determined the aqueous sampling rates (R(S)s; expressed as effective volumes of water extracted daily) of the standard (commercially available design) 1-g triolein SPMD for 15 of the priority pollutant (PP) polycyclic aromatic hydrocarbons (PAHs) at multiple temperatures and concentrations. Under the experimental conditions of this study, recovery-corrected R-S values for PP PAHs ranged from approximate to 1.0 to 8.0 L/d. These values would be expected to be influenced by significant changes (relative to this study) in water temperature, degree of biofouling, and current velocity-turbulence. Included in this paper is a discussion of the effects of temperature and octanol-water partition coefficient (K-OW); the impacts of biofouling and hydrodynamics are reported separately. Overall, SPMDs responded proportionally to aqueous PAH concentrations; i.e., SPMD R-S values and SPMD-water concentration factors were independent of aqueous concentrations. Temperature effects (10, 18, and 26 degrees C) on R-S values appeared to be complex but were relatively small.
引用
收藏
页码:3918 / 3923
页数:6
相关论文
共 50 条
  • [21] Uptake of weakly hydrophobic nitroaromatics from water by semipermeable membrane devices (SPMDs) and by goldfish (Carassius auratus)
    Wang, Y
    Wang, ZJ
    Wang, CX
    Wang, WH
    CHEMOSPHERE, 1999, 38 (01) : 51 - 66
  • [22] Uptake of moderately hydrophobic chlorophenols from water by semipermeable membrane devices (SPMDs) and by goldfish (Crassius auratus)
    Wang, Y
    Wang, CX
    Wang, ZJ
    CHEMOSPHERE, 1998, 37 (02) : 327 - 339
  • [23] Comparison of PAH and nonylphenol Uptake by Carp (Cyprinus carpio) and Semipermeable Membrane Devices (SPMDs) from Water
    J. Xu
    P. Wang
    X. Zhong
    S. Dai
    H. Sun
    Y. Hao
    Bulletin of Environmental Contamination and Toxicology, 2006, 77 : 211 - 218
  • [24] Comparison of PAH and nonylphenol uptake by carp (Cyprinus carpio) and semipermeable membrane devices (SPMDs) from water
    Xu, J.
    Wang, P.
    Zhong, X.
    Dai, S.
    Sun, H.
    Hao, Y.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2006, 77 (02) : 211 - 218
  • [26] Calibrating the uptake kinetics of semipermeable membrane devices in water:: Impact of hydrodynamics
    Vrana, B
    Schüürmann, G
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (02) : 290 - 296
  • [27] Optimization of a methodology for sampling of five polycyclic aromatic hydrocarbons in saline waters using a semipermeable membrane device
    Goncalves, Aline D.
    Robaina, Nicolle F.
    dos Reis, Luis Gustavo T.
    Cassella, Ricardo J.
    MICROCHEMICAL JOURNAL, 2015, 122 : 96 - 101
  • [28] EVALUATION OF LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANOCHLORINE CONTAMINANTS IN THE UPPER MISSISSIPPI RIVER
    ELLIS, GS
    HUCKINS, JN
    ROSTAD, CE
    SCHMITT, CJ
    PETTY, JD
    MACCARTHY, P
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1995, 14 (11) : 1875 - 1884
  • [29] Polycyclic aromatic hydrocarbons (PAHs): Updated aspects of their determination, kinetics in the human body, and toxicity
    Barbosa, Fernando
    Rocha, Bruno A.
    Souza, Marilia C. O.
    Bocato, Mariana Z.
    Azevedo, Lara F.
    Adeyemi, Joseph A.
    Santana, Anthony
    Campiglia, Andres D.
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART B-CRITICAL REVIEWS, 2023, 26 (01): : 28 - 65
  • [30] Estimation of the uptake rate constants for polycyclic aromatic hydrocarbons accumulated by semipermeable membrane devices and triolein-embedded cellulose acetate membranes
    Ke, Runhui
    Xu, Yiping
    Wang, Zijian
    Khan, Shahamat U.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (12) : 3906 - 3911