Optimised Analysis, Design, and Fabrication of Trans-Tibial Prosthetic Sockets

被引:4
|
作者
Jweeg, Muhsin J. [1 ]
Hammoudi, Zaid S. [2 ]
Alwan, Bassam A. [2 ]
机构
[1] Telafer Univ, Mosul, Iraq
[2] Diyala Univ, Coll Engn, Baqubah, Iraq
关键词
Stump length; Composite material; Trans-tibial; Testing of materials;
D O I
10.1088/1757-899X/433/1/012058
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, two laminated composite materials were used to manufacture residuallimb prosthetic sockets using the vacuum moulding method. Acrylic was used as a matrix material and reinforced with two types of fibres, perlon and carbon. The mechanical properties were calculated using tensile and bending tests, and socket failure characteristics at room temperature were determined by using a fatigue test. F-socket apparatus was used to measure the interface pressure between the residual limb and socket in two subjects with unilateral trans-tibial amputations using patellar tendon bearing prosthetics (PTB). The ANSYS program was used to calculate the deformation, maximum principle stress, and safety factors. The results showed that laminations laid-up from eight layers of perlon plus four layers of carbon gave optimum mechanical properties. Comparing this lamination with other laminations of six layers of perlon plus two layers of carbon, in spite the minimal increase in perlon and carbon layers (from eight layers to twelve layers), the ultimate stress increased by 12.46%. The Young's modulus of a lamination with six layers of perlon and four layers of carbon was 3.66 GPa, higher than other laminations investigated. A high Young's Modulus will result in a total contact socket that produces the best comfort level for patients. The maximum principle stress and total deformation increased with an increase in the length of stump: The maximum principle stress of a long socket increased by 0.3% of medium stress, while the total deformation of the medium socket was lower than that of the long socket.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Optimisation of the prescription for trans-tibial (TT) amputees
    Cortés, A
    Viosca, E
    Hoyos, JV
    Prat, J
    Sánchez-Lacuesta, J
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 168 - 174
  • [42] Skew flap technique in trans-tibial amputation
    Jain, SK
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (03) : 283 - 290
  • [43] Prosthetic push-off power in trans-tibial amputee level ground walking: A systematic review
    Mueller, Roy
    Tronicke, Lisa
    Abel, Rainer
    Lechler, Knut
    PLOS ONE, 2019, 14 (11):
  • [44] Biomechanical research of the endoskeletal trans-tibial monolimb
    Liu, Zhan
    Fan, Yubo
    Qian, Yingli
    Zhang, Ming
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1267 - +
  • [45] Functional effects of a prosthetic torsion adapter in trans-tibial amputees during unplanned spin and step turns
    Heitzmann, Daniel W. W.
    Pieschel, Kai
    Alimusaj, Merkur
    Block, Julia
    Putz, Cornelia
    Wolf, Sebastian I.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2016, 40 (05) : 558 - 565
  • [46] Plantar foot pressure responses to changes during dynamic trans-tibial prosthetic alignment in a clinical setting
    Geil, MD
    Lay, A
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2004, 28 (02) : 105 - 114
  • [47] Usability of gait analysis in the alignment of trans-tibial prostheses: A clinical study
    Van Velzen, JM
    Houdijk, H
    Polomski, W
    Van Bennekom, CAM
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (03) : 255 - 267
  • [48] The effects of prosthetic ankle stiffness on ankle and knee kinematics, prosthetic limb loading, and net metabolic cost of trans-tibial amputee gait
    Major, Matthew J.
    Twiste, Martin
    Kenney, Laurence P. J.
    Howard, David
    CLINICAL BIOMECHANICS, 2014, 29 (01) : 98 - 104
  • [49] Comparison of the lightweight Camp Normal Activity Foot with other prosthetic feet in trans-tibial amputees: a pilot study
    van der Water, GJ
    de Vries, J
    Mulder, MA
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1998, 22 (02) : 107 - 114
  • [50] Weight bearing and velocity in trans-tibial and trans-femoral amputees
    Jones, ME
    Bashford, GM
    Mann, JM
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1997, 21 (03) : 183 - 186