Optimised Analysis, Design, and Fabrication of Trans-Tibial Prosthetic Sockets

被引:4
|
作者
Jweeg, Muhsin J. [1 ]
Hammoudi, Zaid S. [2 ]
Alwan, Bassam A. [2 ]
机构
[1] Telafer Univ, Mosul, Iraq
[2] Diyala Univ, Coll Engn, Baqubah, Iraq
关键词
Stump length; Composite material; Trans-tibial; Testing of materials;
D O I
10.1088/1757-899X/433/1/012058
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, two laminated composite materials were used to manufacture residuallimb prosthetic sockets using the vacuum moulding method. Acrylic was used as a matrix material and reinforced with two types of fibres, perlon and carbon. The mechanical properties were calculated using tensile and bending tests, and socket failure characteristics at room temperature were determined by using a fatigue test. F-socket apparatus was used to measure the interface pressure between the residual limb and socket in two subjects with unilateral trans-tibial amputations using patellar tendon bearing prosthetics (PTB). The ANSYS program was used to calculate the deformation, maximum principle stress, and safety factors. The results showed that laminations laid-up from eight layers of perlon plus four layers of carbon gave optimum mechanical properties. Comparing this lamination with other laminations of six layers of perlon plus two layers of carbon, in spite the minimal increase in perlon and carbon layers (from eight layers to twelve layers), the ultimate stress increased by 12.46%. The Young's modulus of a lamination with six layers of perlon and four layers of carbon was 3.66 GPa, higher than other laminations investigated. A high Young's Modulus will result in a total contact socket that produces the best comfort level for patients. The maximum principle stress and total deformation increased with an increase in the length of stump: The maximum principle stress of a long socket increased by 0.3% of medium stress, while the total deformation of the medium socket was lower than that of the long socket.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Parametric analysis using the finite element method to investigate prosthetic interface stresses for persons with trans-tibial amputation
    Silver-Thorn, M. Barbara
    Childress, Dudley S.
    1996, Veterans Administration, Baltimore, MD, United States (33):
  • [32] Mechanical design and evaluation of an actuator and a simulator for trans-tibial and trans-femoral prostheses
    Kapti, Akin Oguz
    Karaca, Ahmet
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2022, 236 (06) : 2665 - 2676
  • [33] The effect of prosthetic alignment on relative limb loading in persons with trans-tibial amputation: A preliminary report
    Pinzur, MS
    Cox, W
    Kaiser, J
    Morris, T
    Patwardhan, A
    Vrbos, L
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1995, 32 (04): : 373 - 377
  • [34] Influence of Prosthetic Sagittal Alignment on Trans-Tibial Amputee Gait and Compensating Pattern:A Case Study
    贾晓红
    王人成
    张明
    李小兵
    Tsinghua Science and Technology, 2008, (05) : 581 - 586
  • [35] Influence of Prosthetic Sagittal Alignment on Trans-Tibial Amputee Gait and Compensating Pattern: A Case Study
    Division of Intelligent and Biomechanical System, State Key Laboratory of Tribology, Tsinghua University, Beijing, 100084, China
    不详
    Tsinghua Sci. Tech., 2008, 5 (581-586):
  • [36] Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
    Lee, WCC
    Zhang, M
    Jia, XH
    Cheung, JTM
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (08) : 655 - 662
  • [37] Load transfer mechanics between trans-tibial prosthetic socket and residual limb - dynamic effects
    Jia, XH
    Zhang, M
    Lee, WCC
    JOURNAL OF BIOMECHANICS, 2004, 37 (09) : 1371 - 1377
  • [38] Review: Problems with Use of Trans-Tibial Prosthesis
    Chatterjee, Subhomoy
    Majumder, Santanu
    RoyChowdhury, Amit
    Pal, Subrata
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (02) : 269 - 284
  • [39] Knee kinetics in trans-tibial amputee gait
    Powers, CM
    Rao, S
    Perry, J
    GAIT & POSTURE, 1998, 8 (01) : 1 - 7
  • [40] Cutaneous sensitivity in unilateral trans-tibial amputees
    Templeton, Cale A.
    Strzalkowski, Nicholas D. J.
    Galvin, Patti
    Bent, Leah R.
    PLOS ONE, 2018, 13 (06):