Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacement

被引:21
|
作者
Puvimanasinghe, JPA
Takkenberg, JJM [1 ]
Eijkemans, MJC
van Herwerden, LA
Jamieson, WRE
Grunkemeier, GL
Habbema, JDF
Bogers, AJJC
机构
[1] Erasmus Univ, Ctr Med, Dept Cardiothoracic Surg, Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
[3] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[4] Providence Hlth Syst, Portland, OR USA
关键词
aortic valve replacement; bioprostheses; prognostic modeling;
D O I
10.1016/j.ejcts.2005.11.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed at calculating and comparing the long-term outcomes of patients after aortic valve replacement with the Carpentier-Edwards bovine pericardial and porcine supraannular bioprostheses using microsimutation. Methods: We conducted a meta-analysis of eight studies on the Carpentier-Edwards pericardial valves (2685 patients, 12,250 patient-years) and five studies on the supraannular valves (3796 patients, 20,127 patient-years) to estimate the occurrence rates of valve-related events. Eighteen-year follow-up data sets were used to construct age-dependent Weibull curves that described their structural valvular deterioration. The estimates were entered into a microsimutation model, which was used to calculate the outcomes of patients after aortic valve replacement. Results: The annual hazard rates for thromboembolism after aortic valve replacement were 1.35% and 1.76% for the pericardial and supraannular valves, respectively. For a 65-year-old mate, median time to structural valvular deterioration was 20.1 and 22.2 years while the lifetime risk of reoperation due to structural valvular deterioration was 18.3% and 14.0%, respectively. The life expectancy of the patient was 10.8 and 10.9 years and event-free life expectancy 9.0 and 8.8 years, respectively. Conclusions: The microsimulation methodology provides insight into the prognosis of a patient after aortic valve replacement with any given valve type. Both the Carpentier-Edwards pericardial and supraannular valve types perform satisfactorily, especially in elderly patients, and show no appreciable difference in long-term outcomes when implanted in the aortic position. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:374 / 379
页数:6
相关论文
共 50 条
  • [31] INTERMEDIATE CLINICAL-RESULTS AFTER AORTIC-VALVE REPLACEMENT WITH THE CARPENTIER-EDWARDS PERICARDIAL BIOPROSTHESIS
    TORKA, MC
    SALEFSKY, BE
    HACKER, RW
    ANNALS OF THORACIC SURGERY, 1995, 60 (02): : S311 - S315
  • [32] Thromboembolic events after aortic valve replacement in elderly patients with a Carpentier-Edwards perimount pericardial bioprosthesis
    Mistiaen, W
    Van Cauwelaert, P
    Muylaert, P
    Sys, SU
    Harrisson, F
    Bortier, H
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (04): : 1166 - 1170
  • [33] Carpentier-Edwards pericardial valve in the aortic position: 25-years experience
    Jose Dalmau, Maria
    CIRUGIA CARDIOVASCULAR, 2014, 21 (01): : 67 - 68
  • [34] 20 years' durability of Carpentier-Edwards Perimount stented pericardial aortic valve
    Bergoend, E.
    Aupart, M. R.
    Mirza, A.
    Meurisse, Y. A.
    Sirinelli, A. L.
    Neville, P. H.
    Marchand, M. A.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 441 - +
  • [35] Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis
    Oda, Takeshi
    Kato, Seiya
    Tayama, Eiki
    Fukunaga, Shrii
    Akashi, Hidetoshi
    Aoyagi, Shigeaki
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (01) : 55 - 57
  • [36] Midterm results of aortic valve replacement with Carpentier-Edwards porcine bioprosthesis
    Sakata J.
    Tsukamoto M.
    Kuwaki K.
    Komatsu K.
    Harada N.
    Abe T.
    Journal of Artificial Organs, 2002, 5 (4) : 246 - 250
  • [37] Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis
    Takeshi Oda
    Seiya Kato
    Eiki Tayama
    Shuji Fukunaga
    Hidetoshi Akashi
    Shigeaki Aoyagi
    Journal of Artificial Organs, 2009, 12 : 55 - 57
  • [38] LONG-TERM EVALUATION OF THE CARPENTIER-EDWARDS PERICARDIAL VALVE IN THE AORTIC POSITION
    PERIER, P
    MIHAILEANU, S
    FABIANI, JN
    DELOCHE, A
    CHAUVAUD, S
    JINDANI, A
    CARPENTIER, A
    JOURNAL OF CARDIAC SURGERY, 1991, 6 (04) : 589 - 594
  • [39] Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience
    Forcillo, Jessica
    Pellerin, Michel
    Perrault, Louis P.
    Cartier, Raymond
    Bouchar, Denis
    Demers, Philippe
    Carrier, Michel
    ANNALS OF THORACIC SURGERY, 2013, 96 (02): : 486 - 493
  • [40] THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - 10-YEAR RESULTS
    COSGROVE, DM
    LYTLE, BW
    TAYLOR, PC
    CAMACHO, MT
    STEWART, RW
    MCCARTHY, PM
    MILLER, DP
    PIEDMONTE, MR
    LOOP, FD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03): : 651 - 662