Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacement

被引:21
|
作者
Puvimanasinghe, JPA
Takkenberg, JJM [1 ]
Eijkemans, MJC
van Herwerden, LA
Jamieson, WRE
Grunkemeier, GL
Habbema, JDF
Bogers, AJJC
机构
[1] Erasmus Univ, Ctr Med, Dept Cardiothoracic Surg, Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
[3] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[4] Providence Hlth Syst, Portland, OR USA
关键词
aortic valve replacement; bioprostheses; prognostic modeling;
D O I
10.1016/j.ejcts.2005.11.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed at calculating and comparing the long-term outcomes of patients after aortic valve replacement with the Carpentier-Edwards bovine pericardial and porcine supraannular bioprostheses using microsimutation. Methods: We conducted a meta-analysis of eight studies on the Carpentier-Edwards pericardial valves (2685 patients, 12,250 patient-years) and five studies on the supraannular valves (3796 patients, 20,127 patient-years) to estimate the occurrence rates of valve-related events. Eighteen-year follow-up data sets were used to construct age-dependent Weibull curves that described their structural valvular deterioration. The estimates were entered into a microsimutation model, which was used to calculate the outcomes of patients after aortic valve replacement. Results: The annual hazard rates for thromboembolism after aortic valve replacement were 1.35% and 1.76% for the pericardial and supraannular valves, respectively. For a 65-year-old mate, median time to structural valvular deterioration was 20.1 and 22.2 years while the lifetime risk of reoperation due to structural valvular deterioration was 18.3% and 14.0%, respectively. The life expectancy of the patient was 10.8 and 10.9 years and event-free life expectancy 9.0 and 8.8 years, respectively. Conclusions: The microsimulation methodology provides insight into the prognosis of a patient after aortic valve replacement with any given valve type. Both the Carpentier-Edwards pericardial and supraannular valve types perform satisfactorily, especially in elderly patients, and show no appreciable difference in long-term outcomes when implanted in the aortic position. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:374 / 379
页数:6
相关论文
共 50 条
  • [21] Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results
    Murakami, T
    Eishi, K
    Nakano, S
    Kobayashi, J
    Sasako, Y
    Isobe, F
    Kosakai, Y
    Kito, Y
    Kawashima, Y
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (01): : 45 - 49
  • [22] Carpentier-Edwards Pericardial Middle-aged Patients Aortic Valve in
    Sakamoto, Yoshimasa
    Hashimoto, Kazuhiro
    Okuyama, Hiroshi
    Ishii, Shinichi
    Inoue, Takahiro
    Kinouchi, Katsushi
    Abe, Takayuki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2005, 53 (09) : 465 - 469
  • [23] HEMODYNAMIC PERFORMANCE OF THE CARPENTIER-EDWARDS PERICARDIAL VALVE IN THE AORTIC POSITION INVIVO
    COSGROVE, DM
    LYTLE, BW
    WILLIAMS, GW
    CIRCULATION, 1985, 72 (03) : 146 - 152
  • [24] INVIVO HEMODYNAMIC PERFORMANCE OF THE CARPENTIER-EDWARDS PERICARDIAL VALVE IN THE AORTIC POSITION
    COSGROVE, DM
    LYTLE, BW
    WILLIAMS, GW
    CIRCULATION, 1984, 70 (04) : 327 - 327
  • [25] Structural valve deterioration in mitral replacement surgery: Comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses - Discussion
    Wolfe, W
    Jamieson
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (02): : 304 - 305
  • [26] A 10-YEAR COMPARISON OF MITRAL-VALVE REPLACEMENT WITH CARPENTIER-EDWARDS AND HANCOCK PORCINE BIOPROSTHESES
    PERIER, P
    DELOCHE, A
    CHAUVAUD, S
    CHACHQUES, JC
    RELLAND, J
    FABIANI, JN
    STEPHAN, Y
    BLONDEAU, P
    CARPENTIER, A
    ANNALS OF THORACIC SURGERY, 1989, 48 (01): : 54 - 59
  • [27] Double valve replacement with the Carpentier-Edwards pericardial valve: 10-year results
    Aupart, MR
    Babuty, DG
    Guesnier, L
    Meurisse, YA
    Sirinelli, AL
    Marchand, MA
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (03): : 312 - 316
  • [28] CLINICAL AND HEMODYNAMIC EVALUATION OF THE 19-MM CARPENTIER-EDWARDS SUPRAANNULAR AORTIC-VALVE
    KALLIS, P
    SNEDDON, JF
    SIMPSON, IA
    FUNG, A
    PEPPER, JR
    SMITH, EEJ
    ANNALS OF THORACIC SURGERY, 1992, 54 (06): : 1182 - 1185
  • [29] CARPENTIER-EDWARDS SUPRAANNULAR PORCINE BIOPROSTHESIS - NEW GENERATION BIOLOGICAL VALVE
    JAMIESON, WRE
    GEREIN, AN
    TYERS, GFO
    ALLEN, P
    MUNRO, AI
    MIYAGISHIMA, RT
    JANUSZ, MT
    BURR, LH
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 245 - 250
  • [30] COMPARISON OF ANTICOAGULATION REGIMENS AFTER CARPENTIER-EDWARDS AORTIC OR MITRAL-VALVE REPLACEMENT
    BLAIR, KL
    HATTON, AC
    WHITE, WD
    SMITH, LR
    LOWE, JE
    WOLFE, WG
    YOUNG, WG
    OLDHAM, HN
    DOUGLAS, JM
    GLOWER, DD
    CIRCULATION, 1994, 90 (05) : 214 - 219