Interactive Initialization for 2D/3D Intra-Operative Registration using the Microsoft Kinect

被引:1
|
作者
Gong, Ren Hui [1 ]
Gueler, Oezgur [1 ]
Yaniv, Ziv [1 ]
机构
[1] Childrens Natl Med Ctr, Sheikh Zayed Inst Pediat Surg Innovat, Washington, DC 20010 USA
来源
MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2013年 / 8671卷
关键词
image-guided therapy; registration initialization; human computer interface; Microsoft Kinect;
D O I
10.1117/12.2008525
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
All 2D/3D anatomy based rigid registration algorithms are iterative, requiring an initial estimate of the 3D data pose. Current initialization methods have limited applicability in the operating room setting, due to the constraints imposed by this environment or due to insufficient accuracy. In this work we use the Microsoft Kinect device to allow the surgeon to interactively initialize the registration process. A Kinect sensor is used to simulate the mouse-based operations in a conventional manual initialization approach, obviating the need for physical contact with an input device. Different gestures from both arms are detected from the sensor in order to set or switch the required working contexts. 3D hand motion provides the six degree-of-freedom controls for manipulating the pre-operative data in the 3D space. We evaluated our method for both X-ray/CT and X-ray/MR initialization using three publicly available reference data sets. Results show that, with initial target registration errors of 117.7 +/- 28.9 mm a user is able to achieve final errors of 5.9 +/- 2.6 mm within 158 +/- 65 sec using the Kinect-based approach, compared to 4.8 +/- 2.0 mm and 88 +/- 60 sec when using the mouse for interaction. Based on these results we conclude that this method is sufficiently accurate for initialization of X-ray/CT and X-ray/MR registration in the OR.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Deep Iterative 2D/3D Registration
    Jaganathan, Srikrishna
    Wang, Jian
    Borsdorf, Anja
    Shetty, Karthik
    Maier, Andreas
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 383 - 392
  • [32] 2D/3D image registration on the GPU
    Kubias A.
    Deinzer F.
    Feldmann T.
    Paulus D.
    Schreiber B.
    Brunner Th.
    Pattern Recognition and Image Analysis, 2008, 18 (03) : 381 - 389
  • [33] Elastic 3D–2D Image Registration
    Paul Striewski
    Benedikt Wirth
    Journal of Mathematical Imaging and Vision, 2022, 64 : 443 - 462
  • [34] Evaluating 2D/3D registration accuracy
    LaRose, D
    Bayouth, J
    Kanade, T
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 147 - 152
  • [35] Soft-Body Registration of Pre-operative 3D Models to Intra-operative RGBD Partial Body Scans
    Modrzejewski, Richard
    Collins, Toby
    Bartoli, Adrien
    Hostettler, Alexandre
    Marescaux, Jacques
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT IV, 2018, 11073 : 39 - 46
  • [36] Towards intra-operative 3D nuclear imaging: Reconstruction of 3D radioactive distributions using tracked gamma probes
    Wendler, Thomas
    Hartl, Alexander
    Lasser, Tobias
    Traub, Joerg
    Daghighian, Farhad
    Ziegler, Sibylle I.
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 909 - +
  • [37] Robust initialization for 2D/3D registration of knee implant models to single-plane fluoroscopy
    Hermans, J.
    Claes, P.
    Bellemans, J.
    Vandermeulena, D.
    Suetens, P.
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [38] Automatic initialization for 3D bone registration
    Foroughi, Pezhman
    Taylor, Russell H.
    Fichtinger, Gabor
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [39] EMBEDDED FEATURE SIMILARITY OPTIMIZATION WITH SPECIFIC PARAMETER INITIALIZATION FOR 2D/3D MEDICAL IMAGE REGISTRATION
    Chen, Minheng
    Zhang, Zhirun
    Gu, Shuheng
    Kong, Youyong
    2024 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, ICASSP 2024, 2024, : 1521 - 1525
  • [40] Evaluation of the Rotational Alignment Accuracy and Error Using 3D/3D, 2D/3D and 3D Surface Registration
    Kuo, H.
    Ballangrud, A.
    Li, G.
    Lovelock, D.
    Wolthuis, B.
    Della-Biancia, C.
    Berry, S.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E307 - E308