Simultaneous Determination of Benserazide and Levodopa in Pharmaceutical Tablet, Human Serum and Urine Sample by Differential Pulse Voltammetry Using Modified Glassy Carbon Electrode

被引:0
|
作者
Naushad, Mu. [1 ]
Gupta, V. K. [2 ]
Wabaidur, S. M. [1 ]
Alothman, Z. A. [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, Adv Mat Res Chair, Riyadh, 11451, Saudi Arabia
[2] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
来源
关键词
Voltammetry; Poly(4-(2-pyridylazo)-resorcinol); Glassy carbon electrode; Benserazide; Levodopa; SELECTIVE POTENTIOMETRIC SENSOR; PERFORMANCE LIQUID-CHROMATOGRAPHY; PYROLYTIC-GRAPHITE ELECTRODE; SUGAR-INDUSTRY WASTE; TIN OXIDE ELECTRODE; BAGASSE FLY-ASH; DE-OILED-SOYA; KINETIC-SPECTROPHOTOMETRIC DETERMINATION; CAPILLARY-ZONE-ELECTROPHORESIS; POLYMERIC MEMBRANE ELECTRODES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple and highly sensitive method was investigated for the simultaneous determination of benserazide (BZ) and levodopa (LD) using Poly(4-(2-pyridylazo)-resorcinol) (PAR) modified glassy carbon electrodes. Both benserazide and levodopa were accumulated at the surface of the modified glassy carbon electrode (under open circuit condition for 30 s). In differential pulse voltammetry technique both BZ and LD were given sensitive oxidation peaks at 180 mV and 270 mV, respectively. Under the optimized experimental conditions (such as supporting electrolyte pH, accumulation time and scanning rate) BZ and LD were shown linear response over the range of 0.01-0.20 mM (r(2) = 0.991) and 0.025-0.4 mM (r(2) = 0.993), respectively. The lower detection limits were found to be 0.002 mM for BZ and 0.006 mM for LD. The commonly encountered excipients used in the pharmaceutical formulation showed no interference with the selective determination of BZ and LD. The investigated method showed good stability, reproducibility (1.3% (BZ) and 2.3% (LD)), repeatability (1.9%) and high recovery in pharmaceutical preparation (1.7% (BZ) and 2.7% (LD)), human serum (1.7% (BZ) and 1.9% (LD)) and urine samples (1.7% (BZ) and 1.8% (LD)).
引用
收藏
页码:297 / 311
页数:15
相关论文
共 50 条
  • [1] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Madakbas, Seyfullah
    Kamiloglu, Senem
    Yetimoglu, Ece Kok
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) : 725 - 730
  • [2] Determination of methylparaben by differential pulse voltammetry using a glassy carbon electrode modified with polypyrrole
    Seyfullah Madakbaş
    Senem Kamiloǧlu
    Ece Kök Yetimoǧlu
    Journal of Analytical Chemistry, 2015, 70 : 725 - 730
  • [3] Simultaneous determination of levodopa and tryptophan using a modified glassy carbon electrode
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Ekrami-Kakhki, Mehri-Saddat
    Divsalar, Kouros
    Shoaie, Iran Sheikh
    Dourandish, Zahra
    Sheikhshoaie, Mahdieh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (04): : 505 - 515
  • [4] Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion®
    Farag, Amir Shaaban
    Pravcova, Katerina
    Ceslova, Lenka
    Vytras, Karel
    Sys, Milan
    ELECTROANALYSIS, 2019, 31 (08) : 1511 - 1516
  • [5] Determination of Amlodipine in pharmaceutical formulations by differential-pulse voltammetry with a glassy carbon electrode
    Altiokka, G
    Dogrukol-Ak, D
    Tunçel, M
    Aboul-Enein, HY
    ARCHIV DER PHARMAZIE, 2002, 335 (2-3) : 104 - 108
  • [6] Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 116 - 130
  • [7] SIMULTANEOUS DETERMINATION OF METHYL SALICYLATE AND THYMOL IN VARIOUS PHARMACEUTICAL FORMULATIONS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE
    LAU, OW
    LUK, SF
    WONG, WC
    ANALYST, 1988, 113 (06) : 865 - 868
  • [8] Simultaneous determination of Levodopa and Carbidopa in pharmaceutical tablets using functionalized multiwall carbon nanotubes modified glassy carbon electrode
    ALOthman, Zeid A.
    Wabaidur, Saikh M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [9] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Nguyen, Do Mai
    Toan Tran, Thanh Tam
    Doan, Manh Dung
    Le, Van Thuan
    Dinh, Quang Khieu
    Chemosphere, 2022, 303
  • [10] Differential pulse voltammetry determination of salbutamol using disulfite tungsten/activated carbon modified glassy carbon electrode
    Do Mai Nguyen
    Thanh Tam Toan Tran
    Manh Dung Doan
    Van Thuan Le
    Quang Khieu Dinh
    CHEMOSPHERE, 2022, 303